Safety and performance of the DRug-Eluting Absorbable Metal Scaffold (DREAMS) in patients with de novo coronary lesions: 3-year results of the prospective, multicentre, first-in-man BIOSOLVE-I trial.

AIMS Bioresorbable scaffolds were designed to overcome the limitations of permanent stents. In the BIOSOLVE-I study we aimed to assess the long-term safety and performance of a drug-eluting absorbable metal scaffold (DREAMS) at three years. METHODS AND RESULTS In this prospective, multicentre first-in-man study, 46 patients with 47 de novo lesions were enrolled. We report the final results at three-year follow-up. Mean age was 65.3±9.7 years, lesions were 2.73±0.48 mm in diameter and 10.99±4.59 mm long. Follow-up at three years was available for 44 patients (one patient died of a non-cardiac cause and one patient withdrew consent). Three target lesion failures (TLF) occurred (6.6%), consisting of two clinically driven target lesion revascularisations at scheduled six-month angiography (4.3%) and one myocardial infarction after drug-eluting balloon treatment in a non-target lesion but target vessel at 12-month angiography (2.2%). No cardiac death or scaffold thrombosis occurred. Seven patients had additional angiographic follow-up at 28±4 months: in-scaffold late lumen loss had improved from 0.51±0.46 mm (median 0.28 mm) at 12 months to 0.32±0.32 mm (median 0.20 mm). CONCLUSIONS The BIOSOLVE-I study showed excellent long-term outcomes at three years with a low TLF rate and no cardiac death or scaffold thrombosis. No TLF event was observed beyond 377 days.

[1]  Soo Teik Lim,et al.  Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial , 2016, The Lancet.

[2]  Patrick W Serruys,et al.  Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe: executive summary. , 2015, European heart journal.

[3]  M. Togni,et al.  Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. , 2015, Journal of the American College of Cardiology.

[4]  P. Serruys,et al.  A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial , 2015, The Lancet.

[5]  Gijs van Soest,et al.  OCT assessment of the long-term vascular healing response 5 years after everolimus-eluting bioresorbable vascular scaffold. , 2014, Journal of the American College of Cardiology.

[6]  P. Serruys,et al.  Assessing bioresorbable coronary devices: methods and parameters. , 2014, JACC. Cardiovascular imaging.

[7]  R. Whitbourn,et al.  Dynamics of vessel wall changes following the implantation of the absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study at 6, 12, 24 and 36 months. , 2014, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[8]  R. Erbel,et al.  Serial Observation of Drug-Eluting Absorbable Metal Scaffold: Multi-Imaging Modality Assessment , 2013, Circulation. Cardiovascular interventions.

[9]  Yoshinobu Onuma,et al.  Bioresorbable Drug-Eluting Magnesium-Alloy Scaffold for Treatment of Coronary Artery Disease , 2013, International journal of molecular sciences.

[10]  P. Serruys,et al.  Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial. , 2013, JACC. Cardiovascular interventions.

[11]  Raimund Erbel,et al.  Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial , 2013, The Lancet.

[12]  Raimund Erbel,et al.  Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries. , 2009, JACC. Cardiovascular interventions.

[13]  Patrick W Serruys,et al.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods , 2009, The Lancet.

[14]  J. Alpert,et al.  Joint ESC/ACCF/AHA/WHF Task Force for the Redefinition of Myocardial Infarction , 2008 .

[15]  P. Serruys,et al.  Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions , 2007, Circulation.

[16]  Fred S Apple,et al.  Universal definition of myocardial infarction. , 2007, Journal of the American College of Cardiology.