An 8-bit microflow controller using pneumatically-actuated microvalves [for semiconductor process gases]

This paper reports a pneumatically actuated, integrated 8-bit mass microflow controller (/spl mu/FC) that utilizes silicon microvalves. It is intended for the precision control of semiconductor process gases in the range from 0.1 to 10 sccm. The structure was designed to be batch-fabricated and compatible with on-chip thermopneumatic actuation. Assembled /spl mu/FC devices operate over a flow range of 0.5-10 sccm at 16 psid (800 torr). The valves alone may achieve significantly higher flow rates. Valve leak rates are as low as 10/sup -3/ sccm under 26 psig actuation pressure. Depositing parylene on the microvalves further improves leak rates by a factor as great as 3.5. This lays the foundation for a precision 0.1-10 sccm microflow controller for process gases, as well as a reliable silicon microvalve for other applications.

[1]  Kensall D. Wise,et al.  Thermally driven phase-change microactuation , 1995 .

[2]  E. Makino,et al.  Thin Film Shape Memory Alloy Microactuators , 2001 .

[3]  M. W. Bruns,et al.  Silicon micromachining and high speed gas chromatography , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[4]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[5]  M. Esashi,et al.  Integrated micro flow control systems , 1990 .

[6]  A. Manz,et al.  Integration Of A Micro Liquid Chromatograph Onto A Silicon Chip , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[7]  Michael Curt Elwenspoek,et al.  Anisotropic reactive ion etching of silicon using SF6/02/CHF3 gas mixtures , 1995 .

[8]  P. W. Barth,et al.  Silicon Microvalves For Gas Flow Control , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[9]  Reuben M. Olson,et al.  Essentials of Engineering Fluid Mechanics , 1968 .

[10]  W. Steckelmacher The effect of cross-sectional shape on the molecular flow in long tubes , 1978 .

[11]  E. S. Kolesar,et al.  Silicon-micromachined gas chromatography system used to separate and detect ammonia and nitrogen dioxide. I. Design, fabrication, and integration of the gas chromatography system , 1994 .

[12]  A. S. Berman Free Molecule Transmission Probabilities , 1965 .