Single-pass lead VDD pacing system in children and adolescents: report of twenty-four patients

The dual-chamber pacing systems allow for AV synchrony, but generally require the placement of two separate transvenous leads. Single-lead atrioventricular synchronous pacing system (VDD) using single-pass leads has been accepted as therapeutic alternative for atrioventricular block with normal sinus node function. The aim of this study is to evaluate clinical performance of single-pass lead VDD pacing systems in 24 consecutive patients in a ten-year period.The study group includes 17 (70.8%) male and 7 (28.8%) female patients.The mean age and mean weight during pacemaker implantation was 10.4 ± 3.8 years (4-17 years) and 30 ± 11 kg (13.5-55 kg), respectively.The patients have been followed for 7-84 months (median 42 months). The percentage of atrial sensing-ventricular pacing changed from 75 to 99.9% at the last control. During the follow-up period, pacing mode was changed to VVIR due to complete loss of AV synchrony in five patients (21%). Four of them had underlying cardiac disease. In these patients loss of AV synchrony might be related to cardiac enlargement/abnormal cardiac anatomy or small atrial dipoleventricular tip length. Despite the loss of AV synchrony in post surgical AV block or dilated cardiomyopathy, single-lead VDD pacing systems can be successfully used in children with complete AV block and normal sinus node function. Patients and lead selection should be taken into consideration for the maintenance of AV synchrony.

[1]  T. Karagöz,et al.  Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker? , 2002, Pediatrics international : official journal of the Japan Pediatric Society.

[2]  A. Manolis,et al.  Comparative three-year performance of chronic atrial sensing among eight different VDD systems. , 2002, The American journal of cardiology.

[3]  L. Toivonen,et al.  Pre-implant determinants of adequate long-term function of single lead VDD pacemakers. , 2002, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  C. Israel,et al.  Single-lead VDD-pacing system incorporating high impedance stimulation: a multicentre study. , 2002, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[5]  J. William Gaynor,et al.  Permanent Epicardial Pacing in Pediatric Patients: Seventeen Years of Experience and 1200 Outpatient Visits , 2001, Circulation.

[6]  H. Seiden,et al.  Use of Single Lead VDD Pacing in Children , 1997, Pacing and clinical electrophysiology : PACE.

[7]  S. Rosenheck,et al.  Single Pass Lead VDD Pacing in Children and Adolescents , 1997, Pacing and clinical electrophysiology : PACE.

[8]  E. Rosenthal,et al.  VDD Pacing in Children with Congenital Complete Heart Block: Advantages of a Single Pass Lead , 1997, Pacing and clinical electrophysiology : PACE.

[9]  C. Noh,et al.  Permanent Epicardial Pacing in Pediatric Patients , 1992 .

[10]  Giuseppe Curzio A Multicenter Evaluation of a Single‐Pass Lead VDD Pacing System , 1991, Pacing and clinical electrophysiology : PACE.