Low effectiveness of prescribed partial weight bearing. Continuous recording of vertical loads using a new pressure-sensitive insole.

To enable objective measurements of weight bearing in hip replacement patients a portable instrument set-up with an on-line registering pressure-sensitive insole was developed. Six men and 9 women, median age 58 (48-67) years, who had been operated on with a cementless or hybrid hip arthroplasty were studied. All patients were independent and functional. A physiotherapist instructed the patients to use crutches in order to support 30% of their body weight. The patients then walked a standardized distance with crutches over five different types of terrain: level, uphill, downhill, upstairs and downstairs. The trial was repeated once. In both men and women most of the steps taken resulted in a load of >30% of body weight. None of the patients managed to comply with the directive, even though five of them thought they did. The type of terrain had no significant influence on the pattern of load. Our findings indicate that the effectiveness of prescribing limited weight bearing is questionable.

[1]  L. Berglund,et al.  Validation of F-Scan pressure sensor system: a technical note. , 1998, Journal of rehabilitation research and development.

[2]  J Kärrholm,et al.  Radiostereometry of hip prostheses. Review of methodology and clinical results. , 1997, Clinical orthopaedics and related research.

[3]  S. Taylor,et al.  Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises. , 1997, Journal of biomechanics.

[4]  M Lord,et al.  Time-Dependent Behaviour of a Force-Sensitive Resistor Plantar Pressure Measurement Insole , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  A Rohlmann,et al.  Influence of shoes and heel strike on the loading of the hip joint. , 1995, Journal of biomechanics.

[6]  B Landjerit,et al.  Bilateral gait patterns in subjects fitted with a total hip prosthesis. , 1995, Archives of physical medicine and rehabilitation.

[7]  S. Toksvig-Larsen,et al.  Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. , 1995, The Journal of bone and joint surgery. British volume.

[8]  T Persson,et al.  A marker-free method to estimate joint centre of rotation by video image processing. , 1995, Computer methods and programs in biomedicine.

[9]  J. Kärrholm,et al.  Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[10]  M A Freeman,et al.  Early migration and late aseptic failure of proximal femoral prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[11]  J Perry,et al.  Functional Recovery of Noncemented Total Hip Arthroplasty , 1993, Clinical orthopaedics and related research.

[12]  Johan Kärrholm,et al.  Early loosening of revision hip arthroplasty , 1990 .

[13]  R W Mann,et al.  Contact pressures from an instrumented hip endoprosthesis. , 1989, The Journal of bone and joint surgery. American volume.

[14]  G Selvik,et al.  Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric study. , 1986, The Journal of bone and joint surgery. British volume.

[15]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[16]  E. Chao,et al.  Biomechanical analysis of foot function during gait and clinical applications. , 1983, Clinical orthopaedics and related research.

[17]  W. Harris,et al.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. , 1969, The Journal of bone and joint surgery. American volume.

[18]  E. Olsson,et al.  Walking ability after total hip replacement. A comparison of gait analysis in unilateral and bilateral cases. , 1992, The Journal of bone and joint surgery. British volume.

[19]  T W Phillips,et al.  Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal. , 1991, Journal of biomechanics.

[20]  M. Bobbert,et al.  Accuracy of determining the point of force application with piezoelectric force plates. , 1990, Journal of biomechanics.

[21]  J. Kärrholm,et al.  Early loosening of revision hip arthroplasty. A roentgen stereophotogrammetric analysis. , 1990, The Journal of arthroplasty.