Quasi-static Deformation Analysis of a Human Finger using a Three-dimensional Finite Element Model Constructed from CT Images

The mechanical deformation of a human fingertip pressed on a flat plate was numerically analyzed using a three-dimensional human fingertip model based on CT images of a human index finger. The fingertip model consisted of three components: the distal phalanx, the nail, and the soft tissue composed of skin and subcutaneous tissue. The analyses were performed for seven different values of Young's moduli in the range 34 to 200 kPa, and for five different values of Poisson's ratios in the range 0.3 to 0.5. The numerical results obtained were compared with reported experimental data for a human fingertip. The numerical results showed that the deformation around the nail and the distal fingertip was generated subsequent to the generation of a large deformation of the pulp. The numerical deformation results showed a similar pattern as the experimental data. Using the numerical results, we calculated the length of the contact area from the lateral view and the width of the contact area from the axial view in order to qualitatively estimate the deformation. By comparing the numerical and experimental results, we found that there were no unique values of Young's modulus and Poisson's ratio for expressing the experimental results. These results suggest that the epidermal, the dermal, and the fat tissue constituting the soft tissue may influence the mechanical deformation by different amounts.

[1]  N. Kamakura,et al.  Patterns of static prehension in normal hands. , 1980, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[2]  M. Srinivasan Surface deflection of primate fingertip under line load. , 1989, Journal of biomechanics.

[3]  T. H.,et al.  The Journal of Bone and Joint Surgery , 2006 .

[4]  C. D. Mote,et al.  Force response of the fingertip pulp to repeated compression--effects of loading rate, loading angle and anthropometry. , 1997, Journal of biomechanics.

[5]  C D Mote,et al.  A method of measuring fingertip loading during keyboard use. , 1994, Journal of biomechanics.

[6]  M. Shrewsbury,et al.  The fascia of the distal phalanx. , 1975, The Journal of bone and joint surgery. American volume.

[7]  The Mechanical Sensitivity of Soft Compressible Testing Machines , 1989 .

[8]  N. Yamazaki,et al.  Relationship between structure of finger tissue and location of tactile receptors , 1997 .

[9]  R G Dong,et al.  Simulation of mechanical responses of fingertip to dynamic loading. , 2002, Medical engineering & physics.

[10]  Y. Fung,et al.  The stress-strain relationship for the skin. , 1976, Journal of biomechanics.

[11]  W. Smutz,et al.  Modeling of time-dependent force response of fingertip to dynamic loading. , 2003, Journal of biomechanics.

[12]  M. Srinivasan,et al.  An investigation of the mechanics of tactile sense using two-dimensional models of the primate fingertip. , 1996, Journal of biomechanical engineering.

[13]  Y. Fung Elasticity of soft tissues in simple elongation. , 1967, The American journal of physiology.

[14]  Mandayam A. Srinivasan,et al.  In vivo compressibility of the human fingertip , 1992 .

[15]  R. Howe,et al.  Dynamic contact of the human fingerpad against a flat surface. , 1999, Journal of biomechanical engineering.

[16]  R. Johansson,et al.  Tactile sensory coding in the glabrous skin of the human hand , 1983, Trends in Neurosciences.

[17]  C. D. Mote,et al.  A structural model of the forced compression of the fingertip pulp. , 1998, Journal of biomechanics.