Accuracy of needle position measurements using fiber Bragg gratings

Abstract Accurate placement of the needle tip is essential in percutaneous therapies such as radiofrequency ablation (RFA) of liver tumors. Use of a robotic system for navigating the needle could improve the targeting accuracy. Real-time information on the needle tip position is needed, since a needle deflects during insertion in tissue. Needle shape can be reconstructed based on strain measurements within the needle. In the current experiment we determined the accuracy with which the needle tip position can be derived from strain measurements using Fiber Bragg Gratings (FBGs). Three glass fibers equipped with two FBGs each were incorporated in a needle. The needle was clamped at one end and deformed by applying static radial displacements at one or two locations. The FBG output was used for offline estimation of the needle shape and tip position. During deflections of the needle tip up to 12.5 mm, the tip position was estimated with a mean accuracy of 0.89 mm (std 0.42 mm). Adding a second deflection resulted in an error of 1.32 mm (std 0.48 mm). This accuracy is appropriate for applications such as RFA of liver tumors. The results further show that the accuracy can be improved by optimizing the placement of FBGs.

[1]  Nobuhiko Hata,et al.  Development and validation of a real-time reduced field of view imaging driven by automated needle detection for MRI-guided interventions , 2010, Medical Imaging.

[2]  G.S. Fischer,et al.  A System for MRI-guided Prostate Interventions , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[3]  Kyle B. Reed,et al.  Mechanics of Flexible Needles Robotically Steered through Soft Tissue , 2010, Int. J. Robotics Res..

[4]  Judith Muehl,et al.  Effects of needle placement inaccuracies in hepatic radiofrequency tumor ablation , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[5]  Katrin Hegenscheid,et al.  Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts , 2010, European Radiology.

[6]  V. Kallem,et al.  Integrated planning and image-guided control for planar needle steering , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[7]  Gabor Fichtinger,et al.  Integrated navigation and control software system for MRI-guided robotic prostate interventions , 2010, Comput. Medical Imaging Graph..

[8]  Andras Lasso,et al.  MRI-Guided Robotic Prostate Biopsy: A Clinical Accuracy Validation , 2010, MICCAI.

[9]  B. Schnackenburg,et al.  Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner , 2010, CardioVascular and Interventional Radiology.

[10]  M. Bock,et al.  Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation , 2008, Magnetic resonance in medicine.

[11]  P. Breedveld,et al.  A new, easily miniaturized steerable endoscope , 2005, IEEE Engineering in Medicine and Biology Magazine.

[12]  R. J. Black,et al.  Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions , 2010, IEEE/ASME Transactions on Mechatronics.

[13]  Vinutha Kallem,et al.  Image Guidance of Flexible Tip-Steerable Needles , 2009, IEEE Transactions on Robotics.

[14]  Daniel Glozman,et al.  Flexible needle steering for percutaneous therapies , 2006, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[15]  Daniel Glozman,et al.  Flexible Needle Steering and Optimal Trajectory Planning for Percutaneous Therapies , 2004, MICCAI.

[16]  W. Lau,et al.  The Current Role of Radiofrequency Ablation in the Management of Hepatocellular Carcinoma: A Systematic Review , 2009, Annals of surgery.

[17]  Yi‐Hsiang Huang,et al.  Percutaneous Ablation Therapy for Hepatocellular Carcinoma: Current Practice and Future Perspectives , 2005, Journal of the Chinese Medical Association : JCMA.

[18]  Masatoshi Kudo,et al.  Radiofrequency Ablation of Hepatocellular Carcinoma: A Literature Review , 2011, International journal of hepatology.

[19]  Daniel Glozman,et al.  Image-Guided Robotic Flexible Needle Steering , 2007, IEEE Transactions on Robotics.