3-D reconstruction of historical documents using an X-Ray C-Arm CT system

There exist historical documents that can not be inspected without damaging them. We present a non-invasive method for the reconstruction of historical documents which have been written with iron gall ink. Iron gall ink has been used since the 5th century and is still in use as an indelible ink for writings and drawings. The fact, that this kind of ink is based on metallic particles leads to the assumption that modern X-Ray scanners could image the writings such that it can be differentiated from the paper mainly consisting of cellulose. Our work shows a method that is capable of imaging writings written with iron gall ink by using a modern X-Ray imaging system that is commonly used for medical applications. Even though the imaging system is not optimized for the given task, the writing can be identified. Furthermore, we present a method that is able to reconstruct the volume even if the phantom is not centered properly or misaligned. Applying this method makes it possible to image books, writings or drawings based on all metal-containing inks without page-turning or unrolling the paper.

[1]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[2]  W. Marsden I and J , 2012 .

[3]  Gengsheng Lawrence Zeng,et al.  Medical Image Reconstruction: A Conceptual Tutorial , 2010 .

[4]  Emmanuel Brun,et al.  Revealing letters in rolled Herculaneum papyri by X-ray phase-contrast imaging , 2015, Nature Communications.

[5]  Matija Strlič,et al.  Historical iron gall ink containing documents — Properties affecting their condition , 2006 .

[6]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[7]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[8]  Burkhard Beckhoff,et al.  Characterization of iron‐gall inks in historical manuscripts and music compositions using x‐ray fluorescence spectrometry , 2004 .

[9]  Jean-Marie Rocchisani,et al.  Reconstruction in Positron Emission Tomography , 2015 .

[10]  Leif Glaser,et al.  The basics of fast-scanning XRF element mapping for iron-gall ink palimpsests. , 2014 .

[11]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[12]  Günter Lauritsch,et al.  Imaging with Flat-Detector CArm systems , 2008 .

[13]  Christian Riess,et al.  CONRAD--a software framework for cone-beam imaging in radiology. , 2013, Medical physics.

[14]  Rebecca Fahrig,et al.  GPU Denoising for Computed Tomography , 2018 .

[15]  Rebecca Fahrig,et al.  Fast simulation of x-ray projections of spline-based surfaces using an append buffer , 2012, Physics in medicine and biology.

[16]  Günter Lauritsch,et al.  3D Imaging with Flat-Detector C-Arm Systems , 2009 .

[17]  V. Corregidor,et al.  Compositional characterization of iron gall inks in manuscripts , 2015, Microscopy and Microanalysis.

[18]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.