Interarea Oscillation Damping Controls for Wind Power Plants

This paper investigates the potential for wind power plants (WPPs) to damp interarea modes. Interarea modes may be the result of a single or a group of generators oscillating against another group of generators across a weak transmission link. If poorly damped, these power system oscillations can cause system instability and potentially lead to blackouts. Power conversion devices, particularly, megawatt-scale converters that connect wind turbines and photovoltaic power plants to the grid, could be used to damp these oscillations by injecting power into the system out of phase with the potentially unstable mode. In our model, this power may be provided by a WPP. Over time, the net energy injection is near zero; therefore, providing this static damping capability is not expected to affect the energy production of a WPP. This is a measurement-based investigation that employs simulated measurement data. It is not a traditional small-signal stability analysis based on Eigenvalues and knowledge of the power system network and its components. Kundurs well-known two-area, four-generator system and a doubly fed induction generator (DFIG)-based WPP are modeled in PSCAD/EMTDC. The WPP model is based on the Western Electricity Coordination Council (WECC) standard model. A controller to damp interarea oscillations is added to the WECC DFIG model, and its effects are studied. Analysis is performed on the data generated by the simulations. The sampling frequency is set to resemble the sampling frequency at which data are available from phasor measurement units in the real world. The YuleWalker algorithm is used to estimate the power spectral density of these signals.

[1]  G. J. Rogers,et al.  A fundamental study of inter-area oscillations in power systems , 1991 .

[2]  Nicholas Jenkins,et al.  Frequency support from doubly fed induction generator wind turbines , 2007 .

[3]  P.J. Nolan,et al.  Coordinated Application of Stabilizers in Multimachine Power Systems , 1980, IEEE Transactions on Power Apparatus and Systems.

[4]  T. Thiringer,et al.  Temporary Primary Frequency Control Support by Variable Speed Wind Turbines— Potential and Applications , 2008, IEEE Transactions on Power Systems.

[5]  S. Lefebvre,et al.  A spectral algorithm for extracting power system modes from time recordings , 1992 .

[6]  B.M. Nomikos,et al.  Contribution of Doubly Fed Wind Generators to Oscillation Damping , 2009, IEEE Transactions on Energy Conversion.

[7]  A. Mullane,et al.  Frequency control and wind turbine technologies , 2005, IEEE Transactions on Power Systems.

[8]  J. G. Slootweg,et al.  The impact of large scale wind power generation on power system oscillations , 2003 .

[9]  J.A.P. Lopes,et al.  Impact of large scale wind power integration on small signal stability , 2005, 2005 International Conference on Future Power Systems.

[10]  G.K. Venayagamoorthy,et al.  Optimal design of power system stabilizers using a small population based PSO , 2006, 2006 IEEE Power Engineering Society General Meeting.

[11]  R. Watson,et al.  Frequency Response Capability of Full Converter Wind Turbine Generators in Comparison to Conventional Generation , 2008, IEEE Transactions on Power Systems.

[12]  I Kamwa,et al.  Adaptive Phasor and Frequency-Tracking Schemes for Wide-Area Protection and Control , 2011, IEEE Transactions on Power Delivery.

[13]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[14]  E. Muljadi,et al.  Equivalencing the collector system of a large wind power plant , 2006, 2006 IEEE Power Engineering Society General Meeting.

[15]  Daniel J. Trudnowski,et al.  Initial results in electromechanical mode identification from ambient data , 1997 .

[16]  Mohit Singh,et al.  Dynamic models for wind turbines and wind power plants , 2011 .

[17]  A. Buckspan,et al.  Combining droop curve concepts with control systems for wind turbine active power control , 2012, 2012 IEEE Power Electronics and Machines in Wind Applications.

[18]  T. Sarkar,et al.  Using the matrix pencil method to estimate the parameters of a sum of complex exponentials , 1995 .

[19]  Kara Clark,et al.  Western Wind and Solar Integration Study , 2011 .

[20]  P. Kundur,et al.  Power system stability and control , 1994 .

[21]  Vijay Vittal,et al.  Impact of increased penetration of DFIG based wind turbine generators on transient and small signal stability of power systems , 2009, IEEE PES General Meeting.

[22]  G. Andersson,et al.  Influence of Hydro Units' Generator-to-Turbine Inertia Ratio on Damping of Subsynchronous Oscillations , 1984 .

[23]  Eduard Muljadi,et al.  Development and Validation of WECC Variable Speed Wind Turbine Dynamic Models for Grid Integration Studies , 2007 .