Simultaneous screening of targeted and non-targeted contaminants using an LC-QTOF-MS system and automated MS/MS library searching.

Simultaneous high-resolution full-scan and tandem mass spectrometry (MS/MS) analysis using time of flight mass spectrometry brings an answer for increasing demand of retrospective and non-targeted data analysis. Such analysis combined with spectral library searching is a promising tool for targeted and untargeted screening of small molecules. Despite considerable extension of the panel of compounds of tandem mass spectral libraries, the heterogeneity of spectral data poses a major challenge against the effective usage of spectral libraries. Performance evaluation of available LC-MS/MS libraries will significantly increase credibility in the search results. The present work was aimed to evaluate fluctuation of MS/MS pattern, in the peak intensities distribution together with mass accuracy measurements, and in consequence, performance compliant with ion ratio and mass error criteria as principles in identification processes for targeted and untargeted contaminants at trace levels. Matrix effect and ultra-trace levels of concentration (from 50 ng l(-1) to 1000 ng l(-1) were evaluated as potential source of inaccuracy in the performance of spectral matching. Matrix-matched samples and real samples were screened for proof of applicability. By manual review of data and application of ion ratio and ppm error criteria, false negatives were obtained; this number diminished when in-house library was used, while with on-line MS/MS databases 100% of positive samples were found. In our experience, intensity of peaks across spectra was highly correlated to the concentration effect and matrix complexity. In turn, analysis of spectra acquired at trace concentrations and in different matrices results in better performance in providing correct and reliable identification.

[1]  Ravi P. Shah,et al.  Identification and characterization of geometrical isomeric photo degradation product of eprosartan using LC-MS and LC-NMR , 2011 .

[2]  W. Niessen,et al.  Fragmentation of toxicologically relevant drugs in positive-ion liquid chromatography-tandem mass spectrometry. , 2011, Mass spectrometry reviews.

[3]  J. V. Sancho,et al.  Multi-class determination of personal care products and pharmaceuticals in environmental and wastewater samples by ultra-high performance liquid-chromatography-tandem mass spectrometry. , 2012, Talanta.

[4]  Dil M. Ramanathan,et al.  High-resolution mass spectrometry method for the detection, characterization and quantitation of pharmaceuticals in water. , 2011, Journal of mass spectrometry : JMS.

[5]  H. Mol,et al.  Full scan MS in comprehensive qualitative and quantitative residue analysis in food and feed matrices: How much resolving power is required? , 2009 .

[6]  Thomas Letzel,et al.  On the inter-instrument and the inter-laboratory transferability of a tandem mass spectral reference library. 3. Focus on ion trap and upfront CID. , 2012, Journal of mass spectrometry : JMS.

[7]  Steven J. Lehotay,et al.  Identification and confirmation of chemical residues in food by chromatography-mass spectrometry and other techniques , 2008 .

[8]  M. Ibáñez,et al.  Confirmation of organic micropollutants detected in environmental samples by liquid chromatography tandem mass spectrometry : Achievements and pitfalls , 2006 .

[9]  H. Mol,et al.  METHOD VALIDATION AND QUALITY CONTROL PROCEDURES FOR PESTICIDE RESIDUES ANALYSIS IN FOOD AND FEED , 2008 .

[10]  David S. Wishart,et al.  HMDB 3.0—The Human Metabolome Database in 2013 , 2012, Nucleic Acids Res..

[11]  A. Fernández-Alba,et al.  Simultaneous measurement in mass and mass/mass mode for accurate qualitative and quantitative screening analysis of pharmaceuticals in river water. , 2012, Journal of chromatography. A.

[12]  Markus Chimani,et al.  Fast alignment of fragmentation trees , 2012, Bioinform..

[13]  Ralf Tautenhahn,et al.  An accelerated workflow for untargeted metabolomics using the METLIN database , 2012, Nature Biotechnology.

[14]  M. Hirai,et al.  MassBank: a public repository for sharing mass spectral data for life sciences. , 2010, Journal of mass spectrometry : JMS.

[15]  M. Tysklind,et al.  Multi-residue method for trace level determination of pharmaceuticals in environmental samples using liquid chromatography coupled to triple quadrupole mass spectrometry. , 2012, Talanta.

[16]  Thomas Zichner,et al.  Identifying the unknowns by aligning fragmentation trees. , 2012, Analytical chemistry.

[17]  D. Hochstrasser,et al.  A multi-target screening analysis in human plasma using fast liquid chromatography-hybrid tandem mass spectrometry (Part II). , 2011, Clinical biochemistry.

[18]  S. Böcker,et al.  Computational mass spectrometry for metabolomics: Identification of metabolites and small molecules , 2010, Analytical and bioanalytical chemistry.

[19]  R. Schuhmacher,et al.  On the inter-instrument and inter-laboratory transferability of a tandem mass spectral reference library: 1. Results of an Austrian multicenter study. , 2009, Journal of mass spectrometry : JMS.

[20]  W. Püttmann,et al.  Occurrence and removal of lidocaine, tramadol, venlafaxine, and their metabolites in German wastewater treatment plants , 2012, Environmental Science and Pollution Research.

[21]  Stephen Stein,et al.  Mass spectral reference libraries: an ever-expanding resource for chemical identification. , 2012, Analytical chemistry.

[22]  K. Kripalani,et al.  Biotransformation of irbesartan in man. , 1998, Drug metabolism and disposition: the biological fate of chemicals.

[23]  A. Kaufmann,et al.  False-positive liquid chromatography/tandem mass spectrometric confirmation of sebuthylazine residues using the identification points system according to EU directive 2002/657/EC due to a biogenic insecticide in tarragon. , 2009, Rapid communications in mass spectrometry : RCM.

[24]  A. Fernández-Alba,et al.  Benefits and pitfalls of the application of screening methods for the analysis of pesticide residues in fruits and vegetables. , 2011, Journal of chromatography. A.

[25]  D. Barceló,et al.  Fast and comprehensive multi-residue analysis of a broad range of human and veterinary pharmaceuticals and some of their metabolites in surface and treated waters by ultra-high-performance liquid chromatography coupled to quadrupole-linear ion trap tandem mass spectrometry. , 2012, Journal of chromatography. A.

[26]  L. Stolker,et al.  Trends in the identification of organic residues and contaminants: EC regulations under revision , 2001 .

[27]  J. Ahlner,et al.  Stereoselective determination of venlafaxine and its three demethylated metabolites in human plasma and whole blood by liquid chromatography with electrospray tandem mass spectrometric detection and solid phase extraction. , 2010, Journal of pharmaceutical and biomedical analysis.

[28]  A. Fernández-Alba,et al.  Post-acquisition data processing for the screening of transformation products of different organic contaminants. Two-year monitoring of river water using LC-ESI-QTOF-MS and GCxGC-EI-TOF-MS , 2014, Environmental Science and Pollution Research.

[29]  H. Mol,et al.  Qualitative aspects and validation of a screening method for pesticides in vegetables and fruits based on liquid chromatography coupled to full scan high resolution (Orbitrap) mass spectrometry , 2012, Analytical and Bioanalytical Chemistry.

[30]  David S. Wishart,et al.  HMDB: a knowledgebase for the human metabolome , 2008, Nucleic Acids Res..

[31]  M. Ibáñez,et al.  Combined use of liquid chromatography triple quadrupole mass spectrometry and liquid chromatography quadrupole time-of-flight mass spectrometry in systematic screening of pesticides and other contaminants in water samples. , 2013, Analytica chimica acta.

[32]  A. Fernández-Alba,et al.  Evaluation of relevant time-of-flight-MS parameters used in HPLC/MS full-scan screening methods for pesticide residues. , 2011, Journal of AOAC International.

[33]  A. Fernández-Alba,et al.  Identification and quantification of poly(amidoamine) PAMAM dendrimers of generations 0 to 3 by liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry in aqueous medium. , 2013, Rapid communications in mass spectrometry : RCM.

[34]  P. Shrivastav,et al.  An accurate, rapid and sensitive determination of tramadol and its active metabolite O-desmethyltramadol in human plasma by LC-MS/MS. , 2009, Journal of pharmaceutical and biomedical analysis.