Wobbling and LSF-based maximum likelihood expectation maximization reconstruction for wobbling PET

Abstract Positron emission tomography (PET) is a widely used imaging modality; however, the PET spatial resolution is not yet satisfactory for precise anatomical localization of molecular activities. Detector size is the most important factor because it determines the intrinsic resolution, which is approximately half of the detector size and determines the ultimate PET resolution. Detector size, however, cannot be made too small because both the decreased detection efficiency and the increased septal penetration effect degrade the image quality. A wobbling and line spread function (LSF)-based maximum likelihood expectation maximization (WL-MLEM) algorithm, which combined the MLEM iterative reconstruction algorithm with wobbled sampling and LSF-based deconvolution using the system matrix, was proposed for improving the spatial resolution of PET without reducing the scintillator or detector size. The new algorithm was evaluated using a simulation, and its performance was compared with that of the existing algorithms, such as conventional MLEM and LSF-based MLEM. Simulations demonstrated that the WL-MLEM algorithm yielded higher spatial resolution and image quality than the existing algorithms. The WL-MLEM algorithm with wobbling PET yielded substantially improved resolution compared with conventional algorithms with stationary PET. The algorithm can be easily extended to other iterative reconstruction algorithms, such as maximum a priori (MAP) and ordered subset expectation maximization (OSEM). The WL-MLEM algorithm with wobbling PET may offer improvements in both sensitivity and resolution, the two most sought-after features in PET design.

[1]  D. Mariano-Goulart,et al.  A heuristic statistical stopping rule for iterative reconstruction in emission tomography , 2012, Annals of Nuclear Medicine.

[2]  Gabor T. Herman The Mathematics of Wobbling a Ring of Positron Annihilation Detectors , 1979, IEEE Transactions on Nuclear Science.

[3]  E. Veklerov,et al.  Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing , 1987, IEEE Transactions on Medical Imaging.

[4]  Victor J. Sank,et al.  Sampling Requirements and Detector Motion for Positron Emission Tomography , 1979, IEEE Transactions on Nuclear Science.

[5]  Christopher J. Thompson,et al.  Under-sampling in PET scanners as a source of image blurring , 2005 .

[6]  T. J. Herbert Statistical stopping criteria for iterative maximum likelihood reconstruction of emission images , 1990 .

[7]  E. Hoffman,et al.  A positron-emission transaxial tomograph for nuclear imaging (PETT). , 1975, Radiology.

[8]  M. Sibomana,et al.  Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[9]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[10]  George N. Kontaxakis,et al.  Stopping criterion for the iterative EM-MLE image reconstruction for PET , 1996, Medical Imaging.

[11]  Arman Rahmim,et al.  Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls. , 2013, Medical physics.

[12]  Christer Halldin,et al.  Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  C. Bohm,et al.  A Computer Assisted Ringdector Positron Camera System for Reconstruction Tomography of the Brain , 1978 .

[14]  B. Bendriem,et al.  Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction , 2009, IEEE Transactions on Nuclear Science.

[15]  J. K. Chan,et al.  Circular Ring Transverse Axial Positron Camera for 3-Dimensional Reconstruction of Radionuclides Distribution , 1976, IEEE Transactions on Nuclear Science.

[16]  Jong Beom Ra,et al.  High-resolution circular ring positron tomograph with dichotomic sampling: Dichotom-I , 1983 .