Holmium laser ablation of cartilage: effects of cavitation bubbles

The ablation of fresh harvested porcine femur patellar groove cartilage by a 2.12 micrometers Cr:Tm:Ho:YAG laser in clinically used irradiation conditions was studied. Laser pulses were delivered via a 600 micrometers diameter fiber in isotonic saline. Ablation was investigated as a function of the angle of incidence of the delivery fiber with respect to the cartilage surface (0-90 degrees) and of radiant exposure. Laser pulses with energies of 0.5, 1.0 and 1.5 J and a duration of 250 microseconds were used. A constant fiber tip-tissue distance of 1 mm was maintained for all experiments. The dynamics of the induced vapor bubble and of the ablation process was monitored by time resolved flash videography with a 1 microseconds illumination. Acoustic transients were measured with a piezoelectric PVDF needle probe hydrophone. Bubble attachment to the cartilage surface during the collapse phase, leading to the direct exposition of the cartilage surface to the maximal pressure generated, was observed in all investigated irradiation conditions. Maximal pressure transients of up to 200 bars (at 1 mm distance from the collapse center) were measured at the bubble collapse at irradiation angles >= 60 degrees. No significant pressure variation was observed in perpendicular irradiation conditions as a function of radiant exposure. A significant reduction of the induced pressure for irradiation angles Photonics West PW 48 1995-02-01|1995-02-28 Photonics West '95 PW95 165739 San Jose, CA, United States Laser-Tissue Interaction VI 2391 Ablation II 11

[1]  Douglas Murphy-Chutorian,et al.  Percutaneous coronary angioplasty with mid-infrared laser and a new multifibre catheter , 1990, The Lancet.

[2]  N. Nishioka,et al.  Pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser ablation of fibrocartilage and articular cartilage , 1990, The American journal of sports medicine.

[3]  T G van Leeuwen,et al.  Noncontact tissue ablation by Holmium: YSGG laser pulses in blood , 1991, Lasers in surgery and medicine.

[4]  Siebert Werner Laseranwendung in der Arthroskopie , 1992 .

[5]  A. Lewis,et al.  Photoacoustic injury and bone healing following 193nm excimer laser ablation , 1992, Lasers in surgery and medicine.

[6]  T G van Leeuwen,et al.  Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. , 1992, Journal of the American College of Cardiology.

[7]  H. Scharf,et al.  Cell vitality in cartilage tissue culture following excimer laser radiation: An in vitro examination , 1993, Lasers in surgery and medicine.

[8]  T J Flotte,et al.  Biological effects of laser-induced shock waves: structural and functional cell damage in vitro. , 1993, Ultrasound in medicine & biology.

[9]  Martin Frenz,et al.  Acoustic transient generation in pulsed holmium laser ablation under water , 1994, SPIE LASE.

[10]  G. Delacretaz,et al.  Acoustic transient generation by holmium‐laser‐induced cavitation bubbles , 1994 .

[11]  Martin Frenz,et al.  Thermal and mechanical damage of corneal tissue after free-running and Q-switched mid-infrared laser ablation , 1994, Other Conferences.

[12]  Martin Frenz,et al.  Acoustic transients in pulsed holmium laser ablation: effects of pulse duration , 1995, Other Conferences.

[13]  A J Welch,et al.  Effect of pulse duration on bubble formation and laser‐induced pressure waves during holmium laser ablation , 1996, Lasers in surgery and medicine.