Estimation of tissue resistivities from multiple-electrode impedance measurements.

In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in this study. A statistically constrained minimum-mean-square error estimator (MIMSEE) that minimizes the effects of linearization errors and instrumentation noise is developed and compared to the conventional least-squares error estimator (LSEE). The MIMSEE requires a priori signal and noise information. The statistical constraint signal information was obtained from a priori knowledge of the physiologically allowed range of regional resistivities. The noise constraint information was obtained from a priori knowledge of the linearization error and the instrumentation noise. The torso potentials were simulated by employing a three-dimensional canine torso model. The model consists of four different conductivity regions: heart, right lung, left lung, and body. It is demonstrated that the statistically constrained MIMSEE performs significantly better than the LSEE in determining resistivities. The results based on the torso model indicate that regional resistivities can be estimated to within 40% accuracy of their true values by utilizing a statistically constrained MIMSEE, even if the instrumentation noise is comparable to the measured torso potentials. The errors obtained using the LSEE with the same linearized transfer function and level of instrumentation noise were about five times larger than those obtained using the MIMSEE. For larger measurement errors the MIMSEE performs even better when compared to the LSEE.

[1]  R. O. Martin,et al.  Statistically Constrained Inverse Electrocardiography , 1975, IEEE Transactions on Biomedical Engineering.

[2]  Yongmin Kim,et al.  Optimal Electrode Configurations for External Cardiac Pacing and Defibrillation: An Inhomogeneous Study , 1987, IEEE Transactions on Biomedical Engineering.

[3]  T. Pilkington,et al.  Effects of Geometrical Uncertainties on Electrocardiography , 1981, IEEE Transactions on Biomedical Engineering.

[4]  John G. Webster,et al.  An Impedance Camera for Spatially Specific Measurements of the Thorax , 1978, IEEE Transactions on Biomedical Engineering.

[5]  John G. Webster,et al.  Electrical Impedance Tomography , 1991 .

[6]  B H Brown,et al.  Errors in reconstruction of resistivity images using a linear reconstruction technique. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  N. van Zandwijk,et al.  Lung volume calculations from 81Krm SPECT for the quantification of regional ventilation. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[8]  J.C. Newell,et al.  An electric current tomograph , 1988, IEEE Transactions on Biomedical Engineering.

[9]  D. Isaacson Distinguishability of Conductivities by Electric Current Computed Tomography , 1986, IEEE Transactions on Medical Imaging.

[10]  O. Strand,et al.  Minimum-RMS Estimation of the Numerical Solution of a Fredholm Integral Equation of the First Kind , 1968 .

[11]  A. van Oosterom,et al.  The potential distribution generated by surface electrodes in inhomogeneous volume conductors of arbitrary shape , 1991, IEEE Transactions on Biomedical Engineering.

[12]  Robert Plonsey,et al.  Engineering contributions to biophysical electrocardiography , 1982 .

[13]  R. Barr,et al.  Comparison of Measured Torso Potentials with Those Simulated from Epicardial Potentials for Ventricular Depolarization and Repolarization in the Intact Dog , 1977, Circulation research.

[14]  P. Hua,et al.  Measuring lung resistivity using electrical impedance tomography , 1992, IEEE Transactions on Biomedical Engineering.

[15]  F. J. Claydon,et al.  A volume conductor model of the thorax for the study of defibrillation fields , 1988, IEEE Transactions on Biomedical Engineering.

[16]  B M Eyüboglu,et al.  Methods of cardiac gating applied potential tomography. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[17]  D C Barber,et al.  Applied potential tomography: a new technique for monitoring pulmonary function. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[18]  G. Huiskamp,et al.  Tailored versus realistic geometry in the inverse problem of electrocardiography , 1989, IEEE Transactions on Biomedical Engineering.

[19]  Willis J. Tompkins,et al.  Comparing Reconstruction Algorithms for Electrical Impedance Tomography , 1987, IEEE Transactions on Biomedical Engineering.

[20]  [Electrical properties of biological substances]. , 1986, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering.

[21]  David Barber,et al.  Blood flow imaging using electrical impedance tomography , 1992 .

[22]  M. Foster An Application of the Wiener-Kolmogorov Smoothing Theory to Matrix Inversion , 1961 .

[23]  G. Sun,et al.  Interactive cardiac mapping. I. Data acquisition , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[24]  B. M. Eyuboglu,et al.  In vivo imaging of cardiac related impedance changes , 1989, IEEE Engineering in Medicine and Biology Magazine.

[25]  Thomas Stevens A deterministic view of a statistical method for stable extension of unstable linear problems , 1978 .

[26]  David Isaacson,et al.  NOSER: An algorithm for solving the inverse conductivity problem , 1990, Int. J. Imaging Syst. Technol..

[27]  P. Wolf,et al.  Current Concepts for Selecting the Location, Size and Shape of Defibrillation Electrodes , 1991, Pacing and clinical electrophysiology : PACE.

[28]  Joel Franklin,et al.  Well-posed stochastic extensions of ill-posed linear problems☆ , 1970 .

[29]  N. G. Sepulveda,et al.  Finite element analysis of cardiac defibrillation current distributions , 1990, IEEE Transactions on Biomedical Engineering.