Super-resolution measurements with evanescent-wave fluorescence excitation using variable beam incidence.

The evanescent wave (EW) elicited by total internal reflection of light selectively excites fluorophores in an optical slice above a reflecting dielectric interface. EW excitation eliminates out-of-focus fluorescence present in epiillumination microscopy, and--close to the coverslip--can offer a fivefold enhancement of axial optical sectioning compared to confocal and two-photon microscopy. The decay length of the evanescent field is a function of the refractive indices and light wavelength involved, and is modulated by the beam angle. EW microscopy was used to study the distribution and concentration of fluorophores at or near the interface in the presence of high concentrations in bulk solution. We modified an upright microscope to accommodate the condenser optics needed for EW excitation. Systematic variations of the angle of incidence were attained using an acousto-optical deflector, telecentric optics, and a hemicylindrical prism. The three-dimensional reconstruction of the fluorophore distribution from angle-resolved image stacks results in topographical information with an axial resolution of tens of nanometers. We applied this technique to study the axial position of dye-labeled subcellular storage organelles ('vesicles') of approximately 300 nm diameter in the "footprint" region of living neuroendocrine cells grown on the interface.

[1]  D. Axelrod,et al.  Fluorescence emission at dielectric and metal-film interfaces , 1987 .

[2]  G. Truskey,et al.  Quantitative analysis of variable‐angle total internal reflection fluorescence microscopy (VA‐TIRFM) of cell/substrate contacts , 1994, Journal of microscopy.

[3]  D. Gingell,et al.  Interference reflection microscopy. A quantitative theory for image interpretation and its application to cell-substratum separation measurement. , 1979, Biophysical journal.

[4]  W. Reichert,et al.  Evanescent Detection of Adsorbed Protein Concentration-Distance Profiles: Fit of Simple Models to Variable-Angle Total Internal Reflection Fluorescence Data , 1987 .

[5]  N. J. Harrick,et al.  Internal reflection spectroscopy , 1968 .

[6]  W. Reichert,et al.  DEtermination of fluorescence density profiles of Langmuir-Blodgett-deposited films by analysis of variable-angle fluorescence data curves , 1988 .

[7]  T. Yanagida,et al.  Fluorescence resonance energy transfer between single fluorophores attached to a coiled-coil protein in aqueous solution , 1999 .

[8]  Martin Oheim,et al.  Simple optical configuration for depth-resolved imaging using variable-angle evanescent-wave microscopy , 1999, European Conference on Biomedical Optics.

[9]  B C Lagerholm,et al.  Total internal reflection fluorescence: applications in cellular biophysics. , 1997, Current opinion in biotechnology.

[10]  Kiwamu Saito,et al.  Imaging of single fluorescent molecules and individual ATP turnovers by single myosin molecules in aqueous solution , 1995, Nature.

[11]  C. S. Izzard,et al.  Cell-to-substrate contacts in living fibroblasts: an interference reflexion study with an evaluation of the technique. , 1976, Journal of cell science.

[12]  D. Loerke,et al.  The last few milliseconds in the life of a secretory granule , 1998, European Biophysics Journal.

[13]  Toshio Yanagida,et al.  Direct observation of single kinesin molecules moving along microtubules , 1996, Nature.

[14]  H. Horstmann,et al.  Transport, docking and exocytosis of single secretory granules in live chromaffin cells , 1997, Nature.

[15]  B. Ölveczky,et al.  Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy. , 1997, Biophysical journal.

[16]  K. Murakami,et al.  Single-molecule imaging of RNA polymerase-DNA interactions in real time. , 1999, Biophysical journal.