Lighting quality and energy-efficiency effects on task performance

The adoption of energy efficiency measures in building codes places constraints on lighting designers that they fear will reduce the quality of the lit environment. This experiment was designed to test the hypothesis that lighting quality, as understood by lighting designers, affects the task performance, mood, comfort, health, and aesthetic judgements of office workers. Nine lighting systems were installed in a windowless, 83 m 2 (880 ft 2), open-plan office space containing six workstations. The designs combined three levels of lighting power density (LPD) and three levels of Designers' Lighting Quality (DLQ) (recessed troffers with prismatic lenses; recessed troffers with parabolic louvers; indirect or direct/indirect fixtures). In the low LPD options, the ambient lighting systems were supplemented with task lighting. Temporary office workers (292 in total) each worked for one day under one of the nine lighting conditions. In addition to morning and afternoon visual performance tests, they performed a variety of computer-based and paper-based tasks designed to be representative of modern office work, and completed questionnaires to assess satisfaction and impressions of lighting quality, mood, physical comfort, and social behaviours. The results show that energy-efficient lighting and good-quality lighting can be compatible. For computer-based work, under existing lighting power density limits, parabolic-louvered luminaires provide better verbal-intellectual and clerical task performance than recessed lensed luminaires. Verbal-intellectual task performance and visual performance were better under electronic ballasts than magnetic ballasts, regardless of lighting system. Résumé L'adoption de mesures de rendement énergétique dans les codes du bâtiment impose des contraintes aux éclairagistes qui, selon eux, risquent de réduire la qualité du milieu éclairé. On a conçu cette expérience dans le but de vérifier l'hypothèse selon laquelle la qualité de l'éclairage, comme l'entendent les éclairagistes, influe sur l'exécution des tâches, l'humeur, le confort, la santé et les jugements esthétiques des employés de bureau. Neuf systèmes d'éclairage ont été installés dans un bureau en espace fonctionnel sans fenêtre de 83 m 2 (880 pi 2) contenant six postes de travail. Les modèles combinaient trois niveaux de densité de puissance lumineuse (DPL) et trois niveaux de qualité «concepteur» de l'éclairage (QCÉ) (chemins lumineux encastrés avec verres diffuseurs prismatiques, chemins lumineux encastrés avec paralumes paraboliques, appareils indirects ou directs et indirects). Dans les cas de DPL faibles, les systèmes d'éclairage ambiant ont été complétés par un éclairage direct. Chacun des employés de bureau temporaires (292 en tout) a travaillé pendant une journée dans l'une des neuf …

[1]  Jennifer A. Veitch,et al.  Determinants of Lighting Quality II: Research and Recommendations. , 1996 .

[2]  Jennifer A. Veitch,et al.  CHOICE, PERCEIVED CONTROL, AND PERFORMANCE DECREMENTS IN THE PHYSICAL ENVIRONMENT , 1996 .

[3]  Arthur Rubin Office design measurements for productivity -- a research overview , 1987 .

[4]  R. G. Mistrick,et al.  Quantifying Reactions of Visual Display Operators to Indirect Lighting , 1984 .

[5]  R. Baron,et al.  Effects of indoor lighting (illuminance and spectral distribution) on the performance of cognitive tasks and interpersonal behaviors: The potential mediating role of positive affect , 1992 .

[6]  Kent F. Spreckelmeyer Office Relocation and Environmental Change , 1993 .

[7]  A. Wilkins,et al.  A neurological basis for visual discomfort. , 1984, Brain : a journal of neurology.

[8]  Mark S. Rea,et al.  Toward a Model of Visual Performance: Foundations and Data , 1986 .

[9]  Eric Sundstrom,et al.  Office Noise, Satisfaction, and Performance , 1994 .

[10]  Jennifer A. Veitch,et al.  Perceived room brightness: Pilot study on the effect of luminance distribution , 1995 .

[11]  T. M. Nelson,et al.  Interaction of temperature, illuminance and apparent time on sedentary work fatigue. , 1984, Ergonomics.

[12]  J. Russell,et al.  Evidence for a three-factor theory of emotions , 1977 .

[13]  L. Loe,et al.  Appearance of lit environment and its relevance in lighting design: Experimental study , 1994 .

[14]  Alan Hedge,et al.  Effects of personal and occupational factors on sick building syndrome reports in air-conditioned offices. , 1992 .

[15]  Jennifer A. Veitch,et al.  Demand characteristics and full spectrum lighting effects on performance and mood , 1991 .

[16]  Jennifer A. Veitch,et al.  Lighting system effects on judged lighting quality and facial appearance , 1996 .

[17]  Belinda L. Collins,et al.  Second-Level Post-Occupancy Evaluation Analysis , 1990 .

[18]  S. Fiske,et al.  Social Psychology , 2019, Encyclopedia of Evolutionary Psychological Science.

[19]  Jacob Cohen Statistical Power Analysis for the Behavioral Sciences , 1969, The SAGE Encyclopedia of Research Design.

[20]  A Wilkins,et al.  Intermittent Illumination from Visual Display Units and Fluorescent Lighting Affects Movements of the Eyes Across Text , 1986, Human factors.

[21]  John E. Flynn,et al.  A Guide to Methodology Procedures for Measuring Subjective Impressions in Lighting , 1979 .

[22]  Arnold J. Wilkins,et al.  Fluorescent lighting, headaches and eyestrain , 1989 .

[23]  Craig A. Bernecker,et al.  Uniform Veiling Luminance and Display Polarity Affect VDU User Performance , 1990 .

[24]  Howard B. Lee,et al.  Foundations of Behavioral Research , 1973 .

[25]  Randall M. Chambers,et al.  Exploring the Relationship Between Level of Office Noise and Salary Recommendations: A Preliminary Research Note , 1978 .

[26]  R. Katzev The Impact of Energy-Efficient Office Lighting Strategies on Employee Satisfaction and Productivity , 1992 .

[27]  Jennifer A. Veitch,et al.  Energy-Efficient Lighting Options: Predicted Savings and Occupant Impressions of Lighting Quality , 2000 .

[28]  Daniel Stokols,et al.  Developing Standardized Tools for Assessing Employees' Ratings of Facility Performance , 1990 .

[29]  Fred Bauman,et al.  A field study of thermal environments and comfort in office buildings , 1988 .

[30]  R. Gifford,et al.  Assessing Beliefs about Lighting Effects on Health, Performance, Mood, and Social Behavior , 1996 .

[31]  Jennifer A. Veitch,et al.  Determinants of Lighting Quality I: State of the Science , 1998 .