Rapid measurement of pulse wave velocity via multisite flow displacement

A MR method is presented for measuring pulse wave velocity (PWV) and its application to assessing stiffness in the human thoracic aorta. This one‐dimensional (1D) flow displacement method applies a single RF comb excitation to the vessel, followed by an oscillating frequency encoding gradient, each oscillation providing a 1D projection of the vessel, enabling one to track fluid motion. The currently implemented sequence excites nine slices within a 20‐cm length of vessel and has a temporal resolution of 2.03 msec and a total acquisition time of 140 msec. Offline‐reconstructed position‐versus‐time plots show curvilinear flow displacement trajectories corresponding to fluid motion at each of the excitation positions. The PWV can be reliably calculated by curve‐fitting these trajectories to a model. In vitro studies using compliant tubes demonstrate no significant difference between results obtained using this method and those directly obtained using pressure transducers. Compared to another MR method previously developed in our laboratory, the proposed method displays improved temporal resolution and enhanced ability to extract PWV from vessels exhibiting low peak flow velocity. Preliminary data suggest that this method is feasible for in vivo application and may provide a more accurate estimation of aortic wave velocity among subjects exhibiting low peak flow velocity, such as the elderly or those with impaired cardiac function. Magn Reson Med 52:1351–1357, 2004. © 2004 Wiley‐Liss, Inc.

[1]  W. Nichols,et al.  Arterial Elastance and Wave Reflection Augmentation of Systolic Blood Pressure: Deleterious Effects and Implications for Therapy , 2001, Journal of cardiovascular pharmacology and therapeutics.

[2]  M. Bock,et al.  Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement. , 2000, Physics in medicine and biology.

[3]  S. Laurent,et al.  Aortic Stiffness Is an Independent Predictor of Primary Coronary Events in Hypertensive Patients: A Longitudinal Study , 2002, Hypertension.

[4]  E D Lehmann,et al.  Relation between number of cardiovascular risk factors/events and noninvasive Doppler ultrasound assessments of aortic compliance. , 1998, Hypertension.

[5]  M. L. Wood,et al.  Pulse‐wave velocity measured in one heartbeat using MR tagging , 2002, Magnetic resonance in medicine.

[6]  E. Arias,et al.  Deaths: preliminary data for 2011. , 2012, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[7]  D. Fei,et al.  Rapid aortic wave velocity measurement with MR imaging. , 2001, Radiology.

[8]  Y. Sugishita,et al.  Chronically decreased aortic distensibility causes deterioration of coronary perfusion during increased left ventricular contraction. , 1994, Journal of the American College of Cardiology.

[9]  Reto Meuli,et al.  Estimation of local aortic elastic properties with MRI , 2002, Magnetic resonance in medicine.

[10]  M. Safar,et al.  Aortic pulse wave velocity: an independent marker of cardiovascular risk. , 2002, The American journal of geriatric cardiology.

[11]  D. Kass,et al.  Hemodynamic effects of unloading the old heart. , 1999, American journal of physiology. Heart and circulatory physiology.

[12]  In Vitro Validation of Rapid MR Measurement of Wave Velocity , 1997, Journal of magnetic resonance.

[13]  A. de Roos,et al.  The clinical significance of aortic compliance and its assessment with magnetic resonance imaging. , 2002, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[14]  C J Hardy,et al.  Accuracy of arterial pulse‐wave velocity measurement using MR , 1998, Journal of magnetic resonance imaging : JMRI.

[15]  J. Blacher,et al.  Aortic pulse wave velocity index and mortality in end-stage renal disease. , 2003, Kidney international.

[16]  D. Fei,et al.  Rapid measurement of aortic wave velocity: In vivo evaluation , 2001, Magnetic resonance in medicine.

[17]  Walter J. Lorenz,et al.  Pulsewave velocity measurement using a new real-time MR-method. , 1995, Magnetic resonance imaging.

[18]  J H Duyn,et al.  Fast volume scanning with frequency‐shifted burst MRI , 1994, Magnetic resonance in medicine.

[19]  E. McVeigh,et al.  Pencil excitation with interleaved fourier velocity encoding: NMR measurement of aortic distensibility , 1996, Magnetic resonance in medicine.

[20]  M. E. Safar,et al.  Aortic Pulse Wave Velocity Predicts Cardiovascular Mortality in Subjects >70 Years of Age , 2001, Arteriosclerosis, thrombosis, and vascular biology.

[21]  D N Firmin,et al.  Quantitation of antegrade and retrograde blood flow in the human aorta by magnetic resonance velocity mapping. , 1989, American heart journal.

[22]  A. Dart,et al.  Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size. , 1998, Clinical science.

[23]  M Décorps,et al.  Rapid repetition of the “burst” sequence: The role of diffusion and consequences for imaging , 1996, Magnetic resonance in medicine.