Magnetic resonance safety update 2002: Implants and devices

The preservation of a safe magnetic resonance (MR) environment requires constant vigilance by MR healthcare professionals, particularly with regard to the management of patients with metallic biomedical implants or devices. The variety and complexity of implants and devices constantly changes, requiring continuous attention and diligence with regard to obtaining the most current and accurate information about these objects relative to the MR environment. This review article discusses MR safety and MR compatibility issues and presents important information for a variety of implants and devices, with an emphasis on those objects that have recently undergone evaluation or that require additional consideration because of existing controversy or confusion. J. Magn. Reson. Imaging 2002;16:485–496. © 2002 Wiley‐Liss, Inc.

[1]  T. W. Athey,et al.  Heating Near Implanted Medical Devices by the MRI RF-magnetic Field , 1999, IEEE International Magnetics Conference.

[2]  K V Slavin,et al.  Magnetic characteristics of Yaşargil aneurysm clips. , 1997, Surgical neurology.

[3]  M. Khoo,et al.  Estimation of chemoreflex loop gain using pseudorandom binary CO/sub 2/ stimulation , 1997, IEEE Transactions on Biomedical Engineering.

[4]  E Kanal,et al.  Aneurysm clips: effects of long-term and multiple exposures to a 1.5-T MR system. , 1999, Radiology.

[5]  John Schenck Health Effects and Safety of Static Magnetic Fields , 2000 .

[6]  F G Shellock,et al.  Cardiac pacemakers and implantable cardioverter defibrillators are unaffected by operation of an extremity MR imaging system. , 1999, AJR. American journal of roentgenology.

[7]  V. Tronnier,et al.  Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study. , 1999, Neurosurgery.

[8]  K Katada,et al.  Effects of new titanium cerebral aneurysm clips on MRI and CT images. , 1996, Minimally invasive neurosurgery : MIN.

[9]  J. Fleckenstein,et al.  Safety of MR Scanning in Patients with Nonferromagnetic Aneurysm Clips , 2000, Journal of magnetic resonance imaging : JMRI.

[10]  F G Shellock,et al.  Metallic neurosurgical implants: Evaluation of magnetic field interactions, heating, and artifacts at 1.5‐Tesla , 2001, Journal of magnetic resonance imaging : JMRI.

[11]  A. Sawyer-Glover,et al.  Pre‐MRI procedure screening: recommendations and safety considerations for biomedical implants and devices , 2000 .

[12]  Ashwini Sharan,et al.  Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 tesla , 2002, Journal of magnetic resonance imaging : JMRI.

[13]  F G Shellock,et al.  MR imaging and electronically activated devices. , 2001, Radiology.

[14]  F G Shellock,et al.  MR compatibility of Guglielmi detachable coils. , 1997, Radiology.

[15]  W Koops,et al.  Potential risks and artifacts of magnetic resonance imaging of self-expandable esophageal stents. , 1997, Gastrointestinal endoscopy.

[16]  F G Shellock,et al.  Compatibility of an endoscope designed for use in interventional MR imaging procedures. , 1998, AJR. American journal of roentgenology.

[17]  D L Hayes,et al.  The Effects of Nuclear Magnetic Resonance Imagers on External and Implantable Pulse Generators , 1984, Pacing and clinical electrophysiology : PACE.

[18]  B. Condon,et al.  Potential MR Hazard to Patients With Metallic Heart Valves: The Lenz Effect , 2000, Journal of magnetic resonance imaging : JMRI.

[19]  F G Shellock,et al.  Metallic marking clips used after stereotactic breast biopsy: ex vivo testing of ferromagnetism, heating, and artifacts associated with MR imaging. , 1999, AJR. American journal of roentgenology.

[20]  E Kanal,et al.  Yasargil aneurysm clips: evaluation of interactions with a 1.5-T MR system. , 1998, Radiology.

[21]  W. Wichmann,et al.  Aneurysm clips made of titanium: magnetic characteristics and artifacts in MR. , 1997, AJNR. American journal of neuroradiology.

[22]  C H Chouard,et al.  [Nuclear magnetic resonance and cochlear implant]. , 1997, Annales d'oto-laryngologie et de chirurgie cervico faciale : bulletin de la Societe d'oto-laryngologie des hopitaux de Paris.

[23]  J Gieseke,et al.  MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T. , 2000, Radiology.

[24]  F G Shellock,et al.  Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prostheses exposed to a 1.5‐T MR system , 1994, Journal of magnetic resonance imaging : JMRI.

[25]  L. Kaufman,et al.  Potential hazards in NMR imaging: heating effects of changing magnetic fields and RF fields on small metallic implants. , 1981, AJR. American journal of roentgenology.

[26]  F. Shellock,et al.  Biopsy needles and devices: Assessment of ferromagnetism and artifacts during exposure to a 1.5‐T MR system , 1995, Journal of magnetic resonance imaging : JMRI.

[27]  Frank G Shellock,et al.  New metallic implant used for permanent contraception in women: evaluation of MR safety. , 2002, AJR. American journal of roentgenology.

[28]  P Steendijk,et al.  Development of an MRI‐compatible catheter for pacing the heart: Initial in vitro and in vivo results , 1996, Journal of magnetic resonance imaging : JMRI.

[29]  T F Budinger,et al.  Magnetic resonance imaging of prosthetic heart valves. , 1985, Radiology.

[30]  F G Shellock,et al.  Aneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR System , 2000, Journal of magnetic resonance imaging : JMRI.

[31]  K. Seelos,et al.  Effects of Nuclear Magnetic Resonance Imaging on Cardiac Pacemakers , 1995, Pacing and clinical electrophysiology : PACE.

[32]  Joseph T McFadden,et al.  Aneurysm clips. , 2003, Journal of neurosurgery.

[33]  M. L. Wood,et al.  Magnetic Resonance Procedures: Health Effects and Safety , 2001 .

[34]  F G Shellock,et al.  Implantable spinal fusion stimulator: Assessment of MR safety and artifacts , 2000, Journal of magnetic resonance imaging : JMRI.

[35]  F G Shellock,et al.  Prosthetic heart valves: Evaluation of magnetic field interactions, heating, and artifacts at 1.5 T , 2000, Journal of magnetic resonance imaging : JMRI.

[36]  F. Shellock,et al.  Cardiovascular catheters and accessories: Ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI , 1998, Journal of magnetic resonance imaging : JMRI.

[37]  Frank G Shellock,et al.  MR Safety and the American College of Radiology White Paper. , 2002, AJR. American journal of roentgenology.

[38]  F G Shellock,et al.  High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. , 1988, AJR. American journal of roentgenology.

[39]  F G Shellock,et al.  Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 Tesla. , 2001, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[40]  D L Hayes,et al.  The Effects of Magnetic Resonance Imaging on Implantable Pulse Generators , 1986, Pacing and clinical electrophysiology : PACE.

[41]  W G Bradley,et al.  MR imaging in patients with intracranial aneurysm clips. , 1988, AJNR. American journal of neuroradiology.

[42]  F G Shellock,et al.  Aneurysm clips: assessment of magnetic field interaction associated with a 0.2-T extremity MR system. , 1998, Radiology.

[43]  D L Hayes,et al.  Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. , 1987, Journal of the American College of Cardiology.

[44]  G. P. Graber,et al.  Heating near implanted medical devices by the MRI RF-magnetic field , 1999 .

[45]  W S Hinshaw,et al.  Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. , 1983, Radiology.

[46]  F G Shellock,et al.  Cranial bone flap fixation clamps: compatibility at MR imaging. , 1998, Radiology.

[47]  K Bachmann,et al.  Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. , 1997, American heart journal.

[48]  Paul R. Algra Magnetic Resonance: Bioeffects, Safety, and Patient Management , 1995 .

[49]  G C Johnson Need for caution during MR imaging of patients with aneurysm clips. , 1993, Radiology.

[50]  J E Heiserman,et al.  Titanium aneurysm clips: Part III--Clinical application in 16 patients with subarachnoid hemorrhage. , 1996, Neurosurgery.

[51]  P T Cahill,et al.  Effect of magnetic resonance imaging on DDD pacemakers. , 1986, The American journal of cardiology.

[52]  F G Shellock,et al.  Metallic stents: evaluation of MR imaging safety. , 1999, AJR. American journal of roentgenology.

[53]  H. Hricak,et al.  The Effect of Magnetic Resonance Imagers on Implanted Neurostimulators , 1992, Pacing and clinical electrophysiology : PACE.

[54]  Chung-Kwang Chou,et al.  RF heating of implanted spinal fusion stimulator during magnetic resonance imaging , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[55]  M Coulomb,et al.  [Effects of the magnetic field in magnetic resonance imaging on 15 tested cardiac valve prostheses]. , 1986, Journal de radiologie.

[56]  Alexander V. Kildishev,et al.  Interactions of magnetic resonance imaging radio frequency magnetic fields with elongated medical implants , 2000 .

[57]  Wilson Greatbatch,et al.  Magnetic resonance safety testing of a newly‐developed fiber‐optic cardiac pacing lead , 2002, Journal of magnetic resonance imaging : JMRI.

[58]  B. Persson,et al.  Magnetic resonance imaging and aneurysm clips. Magnetic properties and image artifacts. , 1989, Journal of neurosurgery.

[59]  J. H. Gallagher,et al.  The effects of nuclear magnetic resonance on patients with cardiac pacemakers. , 1983, Radiology.

[60]  F G Shellock,et al.  Metallic surgical instruments for interventional MRI procedures: Evaluation of MR safety , 2001, Journal of magnetic resonance imaging : JMRI.

[61]  Liong Liem,et al.  Magnetic resonance imaging and spinal cord stimulation systems , 1997, Pain.

[62]  A Piepgras,et al.  [Titanium aneurysm clips and their advantages in diagnostic imaging]. , 1995, Der Radiologe.

[63]  F G Shellock,et al.  Ceramic surgical instruments: Ex vivo evaluation of compatibility with MR imaging at 1.5 T , 1996, Journal of magnetic resonance imaging : JMRI.

[64]  M Dujovny,et al.  Aneurysm clip motion during magnetic resonance imaging: in vivo experimental study with metallurgical factor analysis. , 1985, Neurosurgery.

[65]  R. Pettigrew,et al.  Absence of movement of coronary stents after placement in a magnetic resonance imaging field. , 1994, The American journal of cardiology.

[66]  B Lüderitz,et al.  Interference with Cardiac Pacemakers by Magnetic Resonance Imaging: Are There Irreversible Changes at 0.5 Tesla? , 2001, Pacing and clinical electrophysiology : PACE.

[67]  R. Klucznik,et al.  Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome. , 1993, Radiology.

[68]  K Wicklow,et al.  In vitro evaluation of platinum Guglielmi detachable coils at 3 T with a porcine model: safety issues and artifacts. , 2001, Radiology.

[69]  R. Luechinger,et al.  MR imaging in patients with cardiac pacemakers. , 2001, Radiology.

[70]  E Kanal,et al.  Aneurysm clips: evaluation of MR imaging artifacts at 1.5 T. , 1998, Radiology.

[71]  Frank G. Shellock,et al.  Magnetic Resonance: Bioeffects, Safety and Patient Management , 1994 .

[72]  E P Strecker,et al.  Tantalum vascular stents: in vivo evaluation with MR imaging. , 1989, Radiology.

[73]  N Westerhof,et al.  Transesophageal cardiac pacing during magnetic resonance imaging: Feasibility and safety considerations , 1996, Magnetic resonance in medicine.

[74]  F G Shellock,et al.  Spetzler titanium aneurysm clips: compatibility at MR imaging. , 1998, Radiology.

[75]  W G Bradley,et al.  MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. , 1988, Radiology.