Real-time sweat analysis via alternating current conductivity of artificial and human sweat
暂无分享,去创建一个
Jeffrey E. Edwards | Gengchen Liu | Axel Mellinger | Tolga Kaya | Mahmoud Al-omari | B. Sahin | Samuel E. Snelgrove | A. Mellinger | M. Al-omari | Gengchen Liu | T. Kaya | B. Şahin | J. E. Edwards
[1] Bansi D. Malhotra,et al. Recent developments in urea biosensors , 2009 .
[2] Vadim F. Lvovich,et al. Impedance Spectroscopy: Applications to Electrochemical and Dielectric Phenomena , 2012 .
[3] M. J. Esplandiu,et al. Urea impedimetric biosensor based on polymer degradation onto interdigitated electrodes , 2006 .
[4] Luciano Sales Prado,et al. Is sweat rate during steady state exercise related to maximum oxygen uptake , 2006 .
[5] J. Del Coso,et al. Sweat sodium concentration during exercise in the heat in aerobically trained and untrained humans , 2011, European Journal of Applied Physiology.
[6] H. Shwachman,et al. Measurement of the electrical conductivity of sweat; its application to the study of cystic fibrosis of the pancreas. , 1957, Clinical chemistry.
[7] Axel Mellinger,et al. The effect of Na+ and K+ doping on the properties of sol-gel deposited 2-hydroxy-1,4-naphthoquinone thin films , 2013 .
[8] E. Barsoukov,et al. Impedance spectroscopy : theory, experiment, and applications , 2005 .
[9] M D Luque de Castro,et al. Sweat: a sample with limited present applications and promising future in metabolomics. , 2014, Journal of pharmaceutical and biomedical analysis.
[10] Tolga Kaya,et al. Detection of relative [Na+] and [K+] levels in sweat with optical measurements , 2014 .
[11] Andrea Valsesia,et al. Development of a potentiometric biosensor based on nanostructured surface for lactate determination , 2007 .
[12] Joseph Wang,et al. Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring. , 2014, Biosensors & bioelectronics.
[13] A BLOXSOM. The Electrical Conductivity of Electrolytes Found in the Sweat of Patients with Fibrocystic Disease of the Pancreas , 1959, Archives of disease in childhood.
[14] Andrea Ridolfi,et al. BIOTEX—Biosensing Textiles for Personalised Healthcare Management , 2010, IEEE Transactions on Information Technology in Biomedicine.
[15] J. Clancy,et al. Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data. , 2014, Journal of cystic fibrosis : official journal of the European Cystic Fibrosis Society.
[16] C. Alonso,et al. Nanostructured rough gold electrodes for the development of lactate oxidase-based biosensors. , 2010, Biosensors & bioelectronics.
[17] Andrea Tura,et al. Conductivity measures coupled with treatment with ion-exchange resin for the assessment of sodium concentration in physiological fluids: analyses on artificial solutions , 2013 .
[18] Félix Pariente,et al. Design and characterization of a lactate biosensor based on immobilized lactate oxidase onto gold surfaces , 2006 .
[19] Peyman Mirtaheri,et al. Electrode polarization impedance in weak NaCl aqueous solutions , 2005, IEEE Transactions on Biomedical Engineering.
[20] Christopher J. Harvey,et al. Formulation and stability of a novel artificial human sweat under conditions of storage and use. , 2010, Toxicology in vitro : an international journal published in association with BIBRA.
[21] Malcolm Dole,et al. THE VISCOSITY OF AQUEOUS SOLUTIONS OF STRONG ELECTROLYTES WITH SPECIAL REFERENCE TO BARIUM CHLORIDE , 1929 .
[22] Samuel N. Cheuvront,et al. The influence of hydration status on heart rate variability after exercise heat stress , 2005 .
[23] Kyle Smith,et al. A portable optical human sweat sensor , 2014 .
[24] Sophie Lakard,et al. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films. , 2004, Biosensors & bioelectronics.
[25] Swarup Mukherjee,et al. Hydration status of heat-acclimatized youth team players during competition , 2012 .