Laser flow cytometric light scatter and fluorescence pulse width and pulse rise-time sizing of mammalian cells.

In laser flow cytometry, an increasingly popular technique of analytical cytology, quantitative measurements of interest include cell and nuclear diameters. Electronic circuitry for a new cell sizing technique has been developed which measured the time that signal pulses from either fluorescence or light scatter sensors exceed a preset constant fraction of the peak signal amplitude (pulse width) or the time that it takes a signal to rise between constant fractions of the peak signal amplitude on the rising side of the pulse (pulse rise-time). These pulse width or pulse rise-time measurements were related to cell or nuclear diameters and were used in combination to determine nuclear size to cell size ratios. This method of sizing was found to be independent of fluorescent or light-absorbing stain intensity, linearly related to cell or nuclear diameter, and capable of resolving small diameter differences.

[1]  J. Steinkamp,et al.  Flow microfluorometric and light-scatter measurement of nuclear and cytoplasmic size in mammalian cells. , 1976, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[2]  M. Melamed,et al.  Size and refractive index dependence of simple forward angle scattering measurements in a flow system using sharply-focused illumination. , 1977, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[3]  L L Wheeless,et al.  Slit-scan cytofluorometry. , 1973, Acta Cytologica.

[4]  A. Brunsting,et al.  Differential light scattering: A possible method of mammalian cell identification , 1972 .

[5]  P. Todd,et al.  Laser cytophotometric detection of variations in spatial distribution of concanavalin-A cell surface receptors following viral infection. , 1977, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[6]  L. Sternberger,et al.  THE UNLABELED ANTIBODY ENZYME METHOD OF IMMUNOHISTOCHEMISTRY PREPARATION AND PROPERTIES OF SOLUBLE ANTIGEN-ANTIBODY COMPLEX (HORSERADISH PEROXIDASE-ANTIHORSERADISH PEROXIDASE) AND ITS USE IN IDENTIFICATION OF SPIROCHETES , 1970, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[7]  T M Jovin,et al.  Automated cell sorting with flow systems. , 1978, Annual review of biophysics and bioengineering.

[8]  J. M. Crowell,et al.  Pulse-height light-scatter distributions using flow-systems instrumentation. , 1976, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[9]  P. F. Mullaney,et al.  Cell sizing: a small-angle light-scattering method for sizing particles of low relative refractive index. , 1969, Applied optics.

[10]  J. Steinkamp,et al.  AUTOMATED ANALYSIS OF DEOXYRIBONUCLEIC ACID, PROTEIN AND NUCLEAR TO CYTOPLASMIC RELATIONSHIPS IN TUMOR CELLS AND GYNECOLOGIC SPECIMENS , 1974, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[11]  W. R. Angus,et al.  Scattering of Light , 1942, Nature.

[12]  M. Melamed,et al.  Estimation of cell size from pulse shape in flow cytofluorometry. , 1976, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[13]  P. Todd,et al.  Lasar flow cytophotometric immunoperoxidase detection of herpes simplex virus type 2 antigens in infected cultured human cells. , 1976, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[14]  J. Steinkamp,et al.  A new multiparameter separator for microscopic particles and biological cells. , 1973, The Review of scientific instruments.

[15]  J. Hodkinson,et al.  Computations of Light-Scattering and Extinction by Spheres According to Diffraction and Geometrical Optics, and Some Comparisons with the Mie Theory , 1963 .

[16]  G C Salzman,et al.  Cell classification by laser light scattering: identification and separation of unstained leukocytes. , 1975, Acta cytologica.

[17]  R. A. Meyer,et al.  Light scattering from nucleated biological cells. , 1975, Biophysical journal.

[18]  W. Bancroft,et al.  The Scattering of Light , 1931 .

[19]  P. F. Mullaney,et al.  Differential light scattering from spherical mammalian cells. , 1974, Biophysical journal.

[20]  M. Melamed,et al.  Flow cytofluorimetry: discrimination between single cells and cell aggregates by direct size measurements. , 1975, Acta cytologica.

[21]  L L Wheeless,et al.  Slit-scan flow system for automated cytopathology. , 1975, Acta cytologica.

[22]  H. A. Schultens,et al.  Automatic sizing and separation of particles by ratios of light scattering intensities. , 1976, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[23]  P. F. Mullaney,et al.  Cell sizing: a light scattering photometer for rapid volume determination. , 1969, The Review of scientific instruments.

[24]  Wheeless Ll,et al.  Slit-scan cytofluorometry. , 1973 .

[25]  L. Wheeless,et al.  Imaging systems for correlation of false alarms in flow. , 1977, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[26]  P. N. Dean,et al.  The small angle light scattering of biological cells. Theoretical considerations. , 1970, Biophysical journal.