Rigid FEM in a case history of boiler feed pump vibration

Abstract The rigid finite element approach was used to develop a model of an interconnected rotor system supported upon many oil film bearings. The model was applied to a follow-up analysis of a water feed pump vibration elimination problem. Mass redistribution and changes in the system configuration (alignment) were taken into account. The obtained results offer two independent remedies to reduce the level of vibration.