Design and Implementation of Position Sensorless Starting Control in Industrial Drives With Output Filter and Transformer for Oil/Pump Applications

An open velocity loop current regulated sensorless control scheme for both induction and permanent magnetic motor drives with an output sine wave filter and transformer is designed and implemented in this paper. The proposed control scheme provides a low-voltage drive solution for driving medium-voltage motors without substantially oversizing the inverter. Sufficient starting torque is guaranteed with controlled drive and motor current. Laboratory proof-of-concept tests and experimental results on an actual deep well have validated the effectiveness of the proposed control scheme

[1]  R. S. Colby,et al.  An efficiency-optimizing permanent-magnet synchronous motor drive , 1988 .

[2]  R. Paes,et al.  Speed control of electric submersible pumps - the "current" approach , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[3]  K. Radjabli,et al.  Studies and industrial applications for oil field pumps a special brushless synchronous motors , 2004, Fifty-First Annual Conference 2004 Petroleum and Chemical Industry Technical Conference, 2004..

[4]  Frede Blaabjerg,et al.  Hybrid I-f Starting and Observer-Based Sensorless Control of Single-Phase BLDC-PM Motor Drives , 2012, IEEE Transactions on Industrial Electronics.

[5]  E. B. Turner,et al.  Adjustable-speed drive applications in the oil and gas pipeline industry , 1989 .

[6]  Jingbo Liu,et al.  Rotor Position Estimation for Synchronous Machines Based on Equivalent EMF , 2011, IEEE Transactions on Industry Applications.

[7]  Jeremy Andrews,et al.  Control of subsea motors on multi-km cable lengths by Variable Frequency Drives , 2011, Petroleum and Chemical Industry Conference Europe Electrical and Instrumentation Applications.

[8]  Thomas R. Brinner Voltage and Cable Impedance Unbalance in Submergible Oil Well Pumps , 1984, IEEE Transactions on Industry Applications.

[9]  S. Ryvkin,et al.  Sensorless oil drowned pump drive , 2005, Proceedings of the IEEE International Symposium on Industrial Electronics, 2005. ISIE 2005..

[10]  G.L. Skibinski A series resonant sinewave output filter for PWM VSI loads , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[11]  G. Skibinski,et al.  Line and load friendly drive solutions for long length cable applications in electrical submersible pump applications , 2004, Fifty-First Annual Conference 2004 Petroleum and Chemical Industry Technical Conference, 2004..

[12]  F. Blaabjerg,et al.  I-f starting and active flux based sensorless vector control of reluctance synchronous motors, with experiments , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[13]  I. Boldea,et al.  Active Flux Concept for Motion-Sensorless Unified AC Drives , 2008, IEEE Transactions on Power Electronics.

[14]  Gheorghe-Daniel Andreescu,et al.  Stable V/f control system with controlled power factor angle for permanent magnet synchronous motor drives , 2013 .

[15]  Ion Boldea,et al.  Scalar V/f and I-f control of AC motor drives: An overview , 2015, 2015 Intl Aegean Conference on Electrical Machines & Power Electronics (ACEMP), 2015 Intl Conference on Optimization of Electrical & Electronic Equipment (OPTIM) & 2015 Intl Symposium on Advanced Electromechanical Motion Systems (ELECTROMOTION).

[16]  S. Sangwongwanich,et al.  Sensorless control of interior permanent-magnet synchronous motors based on a fictitious permanent-magnet flux model , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[17]  L. Ya. Raskin,et al.  Sensorless drive with synchronous machine and submersible inverter for oil-drowned pump , 2009, 2009 13th European Conference on Power Electronics and Applications.