Condition Monitoring of DSP Based Online Induction Motor External Fault Detection Using TMS320LF2407 DSP

This paper presents the implementation of TMS320LF2407 DSP processor Kit to identify the single phasing fault online, based on the stator current. The Induction motors are most widely used motors in industrial, commercial and residential sectors because of enormous merits of these over the types of available electric motors, as the workhorse in industrial applications. The early detection of these deteriorating conditions in incipient phase and its removal is necessary for the prevention of external failure of the induction motors, reducing repairs costs and motor outage time. The various types of external faults in induction motor are single line-to-ground fault, double line-ground fault, line-line fault, single phasing fault, locked rotor, under voltage, overvoltage, phase sequence reversal of supply voltage and mechanical overload. This proposed method is applied to a 3.3KW three phase induction motor using TMS320LF2407 DSP processor Kit to identify the single phasing fault online, based on the stator current and then the measurement results are analyzed.

[1]  Mohamed Benbouzid,et al.  Induction motor stator faults diagnosis by a current Concordia pattern-based fuzzy decision system , 2003 .

[2]  Mohamed Benbouzid,et al.  A simple fuzzy logic approach for induction motors stator condition monitoring , 2001, IEMDC 2001. IEEE International Electric Machines and Drives Conference (Cat. No.01EX485).

[3]  K. Gulez,et al.  Designing Artificial Neural Networks for Fault Detection in Induction Motors with the TMS 320 C 30 DSP , 1998 .

[4]  Kartik Prasad Basu,et al.  Experimental investigation into operation under single-phasing condition of a three-phase induction motor connected across a zigzag transformer , 2004, IEEE Transactions on Education.

[5]  R. D. Findlay,et al.  Practical measurement of symmetrical component currents in induction motors , 1994, 1994 Proceedings of Canadian Conference on Electrical and Computer Engineering.

[6]  L.F.A. Pereira,et al.  Motor current signature analysis and fuzzy logic applied to the diagnosis of short-circuit faults in induction motors , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[7]  H.A. Toliyat,et al.  DSP implementation of the multiple reference frames theory for the diagnosis of stator faults in a DTC induction motor drive , 2003, IEEE Transactions on Energy Conversion.

[8]  Arindam Ghosh,et al.  Detection of incipient faults in single phase induction motors using fuzzy logic , 1998, Power Quality '98.

[9]  Jiandong Jiang,et al.  Modelling for Interior Faults of Induction Motors and Its Simulation on EMTDC , 2002 .

[10]  Mohamed Benbouzid,et al.  Application of fuzzy logic to induction motors condition monitoring , 1999 .

[11]  J. Salmon,et al.  DSP Speed Control of Single-Phase Induction Motor Using C Programming , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[12]  B. Singh,et al.  A review of stator fault monitoring techniques of induction motors , 2005, IEEE Transactions on Energy Conversion.

[13]  Chen Li'an,et al.  Simulation of motor faults and protections based on MATLAB , 2001, ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501).

[14]  Hamid A. Toliyat,et al.  DSP implementation of the multiple reference frames theory for the diagnosis of stator faults in a DTC induction motor drive , 2005 .