Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder.

BACKGROUND Per-catheter patent ductus arteriosus (PDA) occlusion in dogs with devices intended for humans is associated with technical difficulties, high rates of procedure abandonment, device migration, and residual ductal flow. HYPOTHESIS Use of a custom-made canine duct occluder (Amplatz Canine Duct Occluder, ACDO) would be feasible in dogs of varying weights and somatotypes and effective in occluding a wide range of PDA shapes and sizes. ANIMALS Eighteen client-owned dogs of various breeds with PDA. Weights ranged from 3.8 to 32.3 kg (median, 17.8 kg), and angiographic minimal ductal diameters ranged from 1.1 to 6.9 mm (median, 3.7 mm). Ductal morphologies included types IIA, IIB, and III. METHODS Per-catheter PDA occlusion with the ACDO was performed in all dogs. Persistent or recurrent ductal flow was assessed at the end of the procedure by angiography and at 1 day, 3 months, and >or=12 months after the procedure by echocardiography. RESULTS Successful ACDO placement was achieved in all 18 dogs. One dog required a 2nd procedure with a larger ACDO after the 1st device migrated to the pulmonary vasculature. Complete occlusion was confirmed in 17 of 18 dogs during the procedure, as well as at 1 day and 3 months after the procedure, and in 12 of 13 dogs evaluated at >or=12 months after the procedure. CONCLUSIONS AND CLINICAL IMPORTANCE Per-catheter PDA occlusion in dogs with the ACDO is feasible and effective in dogs of a wide range of weights and somatotypes and with PDAs of varying shapes and sizes.

[1]  P. Smith,et al.  Transcatheter embolisation of patent ductus arteriosus using an Amplatzer vascular plug in six dogs. , 2007, The Journal of small animal practice.

[2]  S. Gordon,et al.  Angiographic classification of patent ductus arteriosus morphology in the dog. , 2006, Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology.

[3]  R. Sanders,et al.  Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device. , 2006, Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology.

[4]  J. Dukes-McEwan,et al.  Long-term follow-up of dogs with patent ductus arteriosus. , 2003, The Journal of small animal practice.

[5]  D. Sisson Use of a self-expanding occluding stent for nonsurgical closure of patent ductus arteriosus in dogs. , 2003, Journal of the American Veterinary Medical Association.

[6]  M. Boller,et al.  Catheter closure of patent ductus arteriosus in dogs: variation in ductal size requires different techniques. , 2003, Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology.

[7]  M. Boller,et al.  Closure of large patent ductus arteriosus with a self-expanding duct occluder in two dogs. , 2002, The Journal of small animal practice.

[8]  B. Corcoran,et al.  Review of left-to-right shunting patent ductus arteriosus and short term outcome in 98 dogs. , 2002, The Journal of small animal practice.

[9]  K. Hagel,et al.  Transvenous embolization of small patent ductus arteriosus with single detachable coils in dogs. , 2001, Journal of veterinary internal medicine.

[10]  N. Sreeram,et al.  Transcatheter closure of patent ductus arteriosus using occluding spring coils. , 2000, Journal of veterinary internal medicine.

[11]  F. Snaps,et al.  Treatment of patent ductus arteriosus by placement of intravascular coils in a pup. , 1995, Journal of the American Veterinary Medical Association.

[12]  Matthew W. Miller,et al.  Echocardiographic and angiographic comparison of ductal dimensions in dogs with patent ductus arteriosus. , 2007, Journal of veterinary internal medicine.

[13]  W. P. Thomas,et al.  Immediate and late outcomes of transarterial coil occlusion of patent ductus arteriosus in dogs. , 2006, Journal of veterinary internal medicine.

[14]  Matthew W. Miller,et al.  Transarterial coil embolization of patent ductus arteriosus in small dogs with 0.025-inch vascular occlusion coils: 10 cases. , 2004, Journal of veterinary internal medicine.

[15]  M. Alwi,et al.  The Amplatzer duct occluder: experience in 209 patients. , 2001, Journal of the American College of Cardiology.

[16]  C. Mullins,et al.  Transcatheter occlusion of a patent ductus arteriosus in a Newfoundland puppy using the Gianturco-Grifka vascular occlusion device. , 1996, Journal of veterinary internal medicine.