Time Domain Formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross Correlation

The Doppler effect is usually described as a frequency shift of the backscattered signals from moving targets with respect to the frequency transmitted. Recently, real-time blood flow imaging has become possible thanks to the development of a new velocity estimator based on phase-shift measurements of successive echoes. However, this method suffers from the well-known limitations of pulse-Doppler instruments. A new formulation is presented which describes the pulse-Doppler effect on the successive echoes from a cloud of moving targets as a progressive translation in time due to the displacement of the scatterers between two excitations. This approach allows us to generate efficiently computer-simulated data in order to evaluate accurately the various processing techniques. Furthermore, it leads to a novel class of velocity estimators in the time domain which measure the time shifts which are proportional to the local blood velocity. Among them, the cross correlation of the received rf signals turns out to be well suited. A local cross-correlation function is first calculated from a consecutive pair of range-gated echoes and the time shift is then determined by searching for the time position with the maximum correlation. The time-correlation technique is shown to provide accurate velocity profiles with broadband transducers. Moreover, the classical velocity limitation of pulse-Doppler is overcome because there is no ambiguity in measuring a time shift instead of a phase shift. These major advantages should make quantitative flow mapping possible and more reliable.

[1]  S. Satomura,et al.  Ultrasonic Doppler Method for the Inspection of Cardiac Functions , 1957 .

[2]  D. Baker Pulsed Ultrasonic Doppler Blood-Flow Sensing , 1970, IEEE Transactions on Sonics and Ultrasonics.

[3]  V. Newhouse,et al.  Ultrasonic random‐signal flow measurement system , 1974 .

[4]  M. Berry,et al.  Random noise in ultrasonic echoes diffracted by blood , 1974 .

[5]  M. Kaveh,et al.  Blood Flow Measurements Using Ultrasonic Pulsed Random Signal Doppler System , 1975, IEEE Transactions on Sonics and Ultrasonics.

[6]  G. Carter,et al.  The generalized correlation method for estimation of time delay , 1976 .

[7]  S. E. Rittgers,et al.  Real-Time Spectrum Analysis and Display of Directional Doppler Ultrasound Blood Velocity Signals , 1980, IEEE Transactions on Biomedical Engineering.

[8]  R.S. Reneman,et al.  A Multigate Pulsed Doppler System with Serial Data Processing , 1981, IEEE Transactions on Sonics and Ultrasonics.

[9]  J. Reid,et al.  An infinite gate pulse Doppler. , 1981, Ultrasound in medicine & biology.

[10]  M Fink,et al.  Ultrasonic signal processing for in vivo attenuation measurement: short time Fourier analysis. , 1983, Ultrasonic imaging.

[11]  Simulation de la réponse acousto-électrique de structures piézoélectriques au moyen d'un algorithme de transformée de Fourier rapide , 1983 .

[12]  J. Woodcock,et al.  Doppler ultrasound and its use in clinical measurement , 1983 .

[13]  J. Cardoso,et al.  Diffraction Effects in Pulse-Echo Measurement , 1984, IEEE Transactions on Sonics and Ultrasonics.

[14]  Jeffrey W. Eberhard,et al.  A New Time Domain Technique for Velocity Measurements Using Doppler Ultrasound , 1985, IEEE Transactions on Biomedical Engineering.

[15]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE Transactions on Sonics and Ultrasonics.

[16]  A C Kak,et al.  An analytical study of Doppler ultrasound systems. , 1985, Ultrasonic imaging.

[17]  P N Wells,et al.  Doppler developments in the last quinquennium. , 1985, Ultrasound in medicine & biology.

[18]  C. Atzeni,et al.  Velocity Profile Reconstruction Using Ultrafast Spectral Analysis of Doppler Ultrasound , 1985, IEEE Transactions on Sonics and Ultrasonics.

[19]  Mani Azimi,et al.  An Analytical Study of Doppler Ultrasound Systems1 , 1985 .

[20]  P. N. Denbigh,et al.  A new method for the demodulation of ultrasonic signals for cross-correlation flowmeters , 1985 .

[21]  R. Kuc Bounds on estimating the acoustic attenuation of small tissue regions from reflected ultrasound , 1985, Proceedings of the IEEE.

[22]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE 1985 Ultrasonics Symposium.

[23]  Richard S. C. Cobbold,et al.  A Stochastic Model of the Backscattered Doppler Ultrasound from Blood , 1986, IEEE Transactions on Biomedical Engineering.