Radiometric measurement of Circuit Breaker interpole switching times

Monitoring the switching times of circuit breakers is important in the condition assessment of the operating mechanism. Although methods exist for this, they are not applicable to existing plant without retrofitting. Recent research shows that arcing produces impulsive radio-frequency radiation. Using direct digital sampling of the antenna signals, impulses from operating circuit breakers (CBs) may be recorded. From timing analysis of the received impulses, the interpole switching time of the CB can be measured. Results of this method are shown for a field trial on a 132-kV SF/sub 6/ CB attached to a capacitor bank. The relationship between the opening and closing impulses is discussed. This method of timing measurement can be applied to an energized CB. Measurement of the interpole switching times is completely noninvasive, whereas the overall switching time requires a clamp CT fitted on the CB wiring.

[1]  R. Watson,et al.  Circuit breaker condition based monitoring developments , 1994 .

[2]  P. L. Fletcher,et al.  A summary of the final results and conclusions of the second international enquiry on the reliability of high voltage circuit-breakers , 1995 .

[3]  A.L.J. Janssen,et al.  CIGRE WG 13.06 studies on the reliability of single pressure SF/sub 6/-gas high-voltage circuit-breakers , 1996 .

[4]  W. Olszewski,et al.  A new generation of control and diagnostic techniques for gas insulated switchgear , 1998, Proceedings of EMPD '98. 1998 International Conference on Energy Management and Power Delivery (Cat. No.98EX137).

[5]  G. F. Montillet,et al.  Design objectives of new digital control and monitoring of high voltage circuit breakers , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[6]  K. Frohlich,et al.  Model-aided diagnosis-a new method for online condition assessment of high voltage circuit breakers , 2000 .

[7]  Philip J. Moore,et al.  Pollution of the radio spectrum from the generation of impulsive noise by high voltage equipment , 2002 .

[8]  E. J. Bartlett,et al.  Analysis of power system transient induced radiation for substation plant condition monitoring , 2001 .

[9]  Philip J. Moore,et al.  Analysis of the radiated electromagnetic field generated by a 132 kV, SF/sub 6/ circuit breaker , 2002, Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[10]  S. E. Wright,et al.  Switching transient fields in substations , 1991 .

[11]  Philip J. Moore,et al.  Fault location using radio frequency emissions , 2001 .

[12]  Francesco Muzi,et al.  Circuit-breaker diagnostics based on continuous wavelet transform , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.