Tilapia fish microbial spoilage monitored by a single optical gas sensor

As consumption of fish and fish-based foods increases, non-destructive monitoring of fish freshness also becomes more prominent. Fish products are very perishable and prone to microbiological growth, not always easily detected by organoleptic evaluation. The analysis of the headspace of fish specimens through gas sensing is an interesting approach to monitor fish freshness. Here we report a gas sensing method for monitoring Tilapia fish spoilage based on the application of a single gas sensitive gel material coupled to an optical electronic nose. The optical signals of the sensor and the extent of bacterial growth were followed over time, and results indicated good correlation between the two determinations, which suggests the potential application of this simple and low cost system for Tilapia fish freshness monitoring.

[1]  Mieke Uyttendaele,et al.  Alternative microbial methods: An overview and selection criteria. , 2010, Food microbiology.

[2]  Seokheun Choi,et al.  Applications and Technology of Electronic Nose for Clinical Diagnosis , 2013 .

[3]  E. Sugawara,et al.  Properties of AdeABC and AdeIJK Efflux Systems of Acinetobacter baumannii Compared with Those of the AcrAB-TolC System of Escherichia coli , 2014, Antimicrobial Agents and Chemotherapy.

[4]  Ivano G. R. Gutz,et al.  A Low-Cost and High-Performance Conductivity Meter , 1997 .

[5]  Daniel Filippini,et al.  Fish freshness detection by a computer screen photoassisted based gas sensor array. , 2007, Analytica chimica acta.

[6]  Hollis G. Potter,et al.  Author Manuscript , 2013 .

[7]  T. Bozoğlu,et al.  Spoilage of Fish and Other Seafoods , 2016 .

[8]  Kok-Gan Chan,et al.  Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations , 2015, Front. Microbiol..

[9]  L. Gram,et al.  Fish spoilage bacteria--problems and solutions. , 2002, Current opinion in biotechnology.

[10]  Ganesh Kumar Mani,et al.  Electronic noses for food quality : a review , 2015 .

[11]  Hsiao-Wen Zan,et al.  One-Minute Fish Freshness Evaluation by Testing the Volatile Amine Gas with an Ultrasensitive Porous-Electrode-Capped Organic Gas Sensor System. , 2017, ACS sensors.

[12]  V. Mirsky,et al.  Virtual sensor array consisting of a single sensor element with variable affinity: An application for analysis of fish freshness , 2017 .

[13]  R. D. Morton Aerobic Plate Count , 2001 .

[14]  C. Vanderzant,et al.  Compendium of Methods for the Microbiological Examination of Foods , 1992 .

[15]  R. Ulijn,et al.  Tunable Gas Sensing Gels by Cooperative Assembly , 2017, Advanced functional materials.

[16]  Murat O. Balaban,et al.  Objective Quality Assessment of Raw Tilapia (Oreochromis niloticus) Fillets Using Electronic Nose and Machine Vision , 2001 .

[17]  Hengwei Lin,et al.  Preoxidation for colorimetric sensor array detection of VOCs. , 2011, Journal of the American Chemical Society.

[18]  Wan-Young Chung,et al.  Novel proximal fish freshness monitoring using batteryless smart sensor tag , 2017 .

[19]  Lawrence Lee Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations. Frontiers in Microbiology. 2015.5:770. doi: 10.3389/fmicb.2014.00770 , 2015 .

[20]  Scott A. Hale,et al.  ELECTRONIC NOSE ANALYSIS OF TILAPIA STORAGE , 2004 .