LC-MS/MS-Based Method for the Multiplex Detection of 24 Fentanyl Analogues and Metabolites in Whole Blood at Sub ng mL–1 Concentrations

The United States and numerous other countries worldwide are currently experiencing a public health crisis due to the abuse of illicitly manufactured fentanyl (IMF) and its analogues. This manuscript describes the development of a liquid chromatography-tandem mass spectrometry-based method for the multiplex detection of N = 24 IMF analogues and metabolites in whole blood at concentrations as low as 0.1–0.5 ng mL–1. These available IMFs were fentanyl, norfentanyl, furanyl norfentanyl, remifentanil acid, butyryl norfentanyl, remifentanil, acetyl fentanyl, alfentanil, AH-7921, U-47700, acetyl fentanyl 4-methylphenethyl, acrylfentanyl, para-methoxyfentanyl, despropionyl fentanyl (4-ANPP), furanyl fentanyl, despropionyl para-fluorofentanyl, carfentanil, (±)-cis-3-methyl fentanyl, butyryl fentanyl, isobutyryl fentanyl, sufentanil, valeryl fentanyl, para-fluorobutyryl fentanyl, and para-fluoroisobutyryl fentanyl. Most IMF analogues (N = 22) could be easily distinguished from one another; the isomeric forms butyryl/isobutyryl fentanyl and para-fluorobutyryl/para-fluoroisobutyryl fentanyl could not be differentiated. N = 13 of these IMF analogues were quantified for illustrative purposes, and their forensic quality control standards were also validated for limit of detection (0.017–0.056 ng mL–1), limit of quantitation (0.100–0.500 ng mL–1), selectivity/sensitivity, ionization suppression/enhancement (87–118%), process efficiency (60–95%), recovery (64–97%), bias (<20%), and precision (>80%). This flexible, time- and cost-efficient method was successfully implemented at the Montgomery County Coroner’s Office/Miami Valley Regional Crime Laboratory in Dayton, Ohio, where it aided in the analysis of N = 725 postmortem blood samples collected from February 2015 to November 2016.

[1]  O. Drummer,et al.  The analysis of 132 novel psychoactive substances in human hair using a single step extraction by tandem LC/MS. , 2017, Forensic science international.

[2]  D. Dolinak,et al.  An LC-MS-MS Method for the Analysis of Carfentanil, 3-Methylfentanyl, 2-Furanyl Fentanyl, Acetyl Fentanyl, Fentanyl and Norfentanyl in Postmortem and Impaired-Driving Cases. , 2017, Journal of analytical toxicology.

[3]  L. Reidy,et al.  Confirmation of Carfentanil, U-47700 and Other Synthetic Opioids in a Human Performance Case by LC-MS-MS. , 2017, Journal of analytical toxicology.

[4]  G. Hime,et al.  Qualitative Identification of Fentanyl Analogs and Other Opioids in Postmortem Cases by UHPLC-Ion Trap-MSn. , 2017, Journal of analytical toxicology.

[5]  Rebecca L. Shaner,et al.  Quantitation of Fentanyl Analogs in Dried Blood Spots by Flow-Through Desorption Coupled to Online Solid Phase Extraction Tandem Mass Spectrometry. , 2017, Analytical methods : advancing methods and applications.

[6]  J. Staymates,et al.  Rapid detection of fentanyl, fentanyl analogues, and opioids for on-site or laboratory based drug seizure screening using thermal desorption DART-MS and ion mobility spectrometry , 2017, Forensic chemistry.

[7]  Joji Suzuki,et al.  A review: Fentanyl and non-pharmaceutical fentanyls. , 2017, Drug and alcohol dependence.

[8]  B. Logan,et al.  Analysis of Novel Synthetic Opioids U-47700, U-50488 and Furanyl Fentanyl by LC-MS/MS in Postmortem Casework. , 2016, Journal of analytical toxicology.

[9]  Chris Delcher,et al.  Increases in Fentanyl-Related Overdose Deaths - Florida and Ohio, 2013-2015. , 2016, MMWR. Morbidity and mortality weekly report.

[10]  A. Helander,et al.  Intoxications involving the fentanyl analogs acetylfentanyl, 4-methoxybutyrfentanyl and furanylfentanyl: results from the Swedish STRIDA project , 2016, Clinical toxicology.

[11]  Michele L. Merves,et al.  Postmortem tissue distribution of acetyl fentanyl, fentanyl and their respective nor-metabolites analyzed by ultrahigh performance liquid chromatography with tandem mass spectrometry. , 2015, Forensic science international.

[12]  I. Papoutsis,et al.  AH-7921: the list of new psychoactive opioids is expanded , 2015, Forensic Toxicology.

[13]  T. Stanley The fentanyl story. , 2014, The journal of pain : official journal of the American Pain Society.

[14]  Rebecca L. Shaner,et al.  Comparison of two automated solid phase extractions for the detection of ten fentanyl analogs and metabolites in human urine using liquid chromatography tandem mass spectrometry. , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[15]  A. Bermejo,et al.  Determination of fentanyl, metabolite and analogs in urine by GC/MS , 2011, Journal of applied toxicology : JAT.

[16]  J. Tytgat,et al.  Development and validation of a sensitive ultra performance liquid chromatography tandem mass spectrometry method for the analysis of fentanyl and its major metabolite norfentanyl in urine and whole blood in forensic context. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[17]  E. Vuori,et al.  Simultaneous screening and quantification of 25 opioid drugs in post-mortem blood and urine by liquid chromatography-tandem mass spectrometry. , 2009, Forensic science international.

[18]  R. Iio,et al.  Use of multiple-reaction monitoring ratios for identifying incompletely resolved fentanyl homologs and analogs via ultra-high-pressure liquid chromatography-tandem mass spectrometry. , 2009, Journal of chromatography. A.

[19]  Herman Joseph,et al.  Opioids and the treatment of chronic pain: controversies, current status, and future directions. , 2008, Experimental and clinical psychopharmacology.

[20]  O. Beck,et al.  Validation of direct injection electrospray LC-MS/MS for confirmation of opiates in urine drug testing. , 2007, Journal of mass spectrometry : JMS.

[21]  Michael L Smith,et al.  Modern instrumental methods in forensic toxicology. , 2007, Journal of analytical toxicology.

[22]  Leigh Anderson,et al.  Quantitative Mass Spectrometric Multiple Reaction Monitoring Assays for Major Plasma Proteins* , 2006, Molecular & Cellular Proteomics.

[23]  A. Poklis,et al.  Direct analysis of opiates in urine by liquid chromatography-tandem mass spectrometry. , 2005, Journal of analytical toxicology.

[24]  M. Telepchak,et al.  Forensic and clinical applications of solid phase extraction , 2005, International Journal of Legal Medicine.

[25]  H. Druid,et al.  A cluster of fentanyl-related deaths among drug addicts in Sweden. , 1997, Forensic science international.

[26]  T. Stanley,et al.  The history and development of the fentanyl series. , 1992, Journal of pain and symptom management.

[27]  G. L. Henderson,et al.  Fentanyl-related deaths: demographics, circumstances, and toxicology of 112 cases. , 1991, Journal of forensic sciences.

[28]  L. Mather Clinical Pharmacokinetics of Fentanyl and its Newer Derivatives , 1983, Clinical pharmacokinetics.

[29]  Raminta Daniulaityte,et al.  Overdose Deaths Related to Fentanyl and Its Analogs - Ohio, January-February 2017. , 2017, MMWR. Morbidity and mortality weekly report.

[30]  Schedules of Controlled Substances: Placement of AH-7921 Into Schedule I. Final order. , 2016, Federal register.

[31]  Scientific Working Group for Forensic Toxicology (SWGTOX) standard practices for method validation in forensic toxicology. , 2013, Journal of analytical toxicology.