NeuroMEMS: Neural Probe Microtechnologies
暂无分享,去创建一个
Sam Musallam | Mohamad HajjHassan | Vamsy Chodavarapu | S. Musallam | V. Chodavarapu | Mohamad HajjHassan
[1] Ulrich G. Hofmann,et al. A neural probe process enabling variable electrode configurations , 2004 .
[2] Daryl R. Kipke,et al. 3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..
[3] Khalil Najafi. Micromachined Systems for Neurophysiological Applications , 1997 .
[4] K. Wise,et al. Silicon ribbon cables for chronically implantable microelectrode arrays , 1994, IEEE Transactions on Biomedical Engineering.
[5] Qing Bai,et al. Single-unit neural recording with active microelectrode arrays , 2001, IEEE Transactions on Biomedical Engineering.
[6] Thomas Stieglitz,et al. Microtechnical Interfaces to Neurons , 1998 .
[7] K. Mabuchi,et al. 3D flexible multichannel neural probe array , 2004 .
[8] T. Stieglitz,et al. Flexible BIOMEMS with Electrode Arrangements on Front and Back Side as Key Component in Neural Prostheses and Biohybrid Systems , 2002 .
[9] K. Frank,et al. CHAPTER 2 – MICROELECTRODES FOR RECORDING AND STIMULATION , 1964 .
[10] K. Wise,et al. A 64-site multishank CMOS low-profile neural stimulating probe , 1996, IEEE J. Solid State Circuits.
[11] K.D. Wise,et al. Silicon microsystems for neuroscience and neural prostheses , 2005, IEEE Engineering in Medicine and Biology Magazine.
[12] Eduardo Fernandez,et al. High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays , 2001, Vision Research.
[13] M. Diamond,et al. Examination of the spatial and temporal distribution of sensory cortical activity using a 100-electrode array , 1999, Journal of Neuroscience Methods.
[14] R. Normann,et al. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.
[15] Kensall D. Wise,et al. Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays , 2005, IEEE Transactions on Biomedical Engineering.
[16] Chenyang Xu,et al. Design and Fabrication of A High Density Metal Microelectrode Array for Neural Recording , 2002 .
[17] David C. Martin,et al. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.
[18] J. Anthony Movshon,et al. Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex , 2007, The Journal of Neuroscience.
[19] R. Britt,et al. Quantitative analysis of methods for reducing physiological brain pulsations , 1982, Journal of Neuroscience Methods.
[20] G. Urban,et al. Early Biomems Multi-Sensor Neuroprobes , 2006 .
[21] J. Y. Lettvin,et al. Comments on Microelectrodes , 1959, Proceedings of the IRE.
[22] Daryl R. Kipke,et al. The role of flexible polymer interconnects in chronic tissue response induced by intracortical microelectrodes - a modeling and an in vivo study , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.
[23] K. Wise,et al. A Low-Profile Three-Dimensional Silicon/Parylene Stimulating Electrode Array for Neural Prosthesis Applications , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[24] T. Hortobágyi,et al. Cross education and the human central nervous system , 2005, IEEE Engineering in Medicine and Biology Magazine.
[25] A. Hodgkin,et al. Action Potentials Recorded from Inside a Nerve Fibre , 1939, Nature.
[26] Daryl R. Kipke,et al. Wireless implantable microsystems: high-density electronic interfaces to the nervous system , 2004, Proceedings of the IEEE.
[27] J. Rizzo,et al. Multi-electrode stimulation and recording in the isolated retina , 2000, Journal of Neuroscience Methods.
[28] M. Fee,et al. Active Stabilization of Electrodes for Intracellular Recording in Awake Behaving Animals , 2000, Neuron.
[29] Christopher R. Stambaugh,et al. Encoding of Tactile Stimulus Location by Somatosensory Thalamocortical Ensembles , 2000, The Journal of Neuroscience.
[30] W. Singer,et al. Synchronous oscillations in the cat retina , 1999, Vision Research.
[31] Hongtao Ma,et al. Neurovascular coupling and oximetry during epileptic events , 2006, Molecular Neurobiology.
[32] J. Hetke,et al. Strength characterization of silicon microprobes in neurophysiological tissues , 1990, IEEE Transactions on Biomedical Engineering.
[33] Murat Okandan,et al. Electrostatic microactuators for precise positioning of neural microelectrodes , 2005, IEEE Transactions on Biomedical Engineering.
[34] L. Geddes. Electrodes and the measurement of bioelectric events , 1972 .
[35] K. Wise,et al. An implantable CMOS circuit interface for multiplexed microelectrode recording arrays , 1992 .
[36] Z. Hashin,et al. A CUMULATIVE DAMAGE THEORY OF FATIGUE FAILURE , 1978 .
[37] K. Najafi,et al. Solid-state microsensors for cortical nerve recordings , 1994, IEEE Engineering in Medicine and Biology Magazine.
[38] D. Szarowski,et al. Brain responses to micro-machined silicon devices , 2003, Brain Research.
[39] Hirokazu Takahashi,et al. Easy-to-prepare assembly array of tungsten microelectrodes , 2005, IEEE Transactions on Biomedical Engineering.
[40] Peter X Ma,et al. Nanostructured Biomaterials for Regeneration , 2008, Advanced functional materials.
[41] Rejean Plamondon,et al. Open Tip Glass Microelectrodes: Conduction Through the Wall at the Tip , 1987, IEEE Transactions on Biomedical Engineering.
[42] J.P. Donoghue,et al. Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[43] Ravi V. Bellamkonda,et al. Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes , 2007, Brain Research.
[44] Jiping He,et al. Polyimide-based intracortical neural implant with improved structural stiffness , 2004 .
[45] D.J. Anderson,et al. Batch fabricated thin-film electrodes for stimulation of the central auditory system , 1989, IEEE Transactions on Biomedical Engineering.
[46] S. Thanos,et al. Implantable bioelectronic interfaces for lost nerve functions , 1998, Progress in Neurobiology.
[47] Khalil Najafi,et al. A scaled electronically-configurable multichannel recording array , 1990 .
[48] E. Valderrama,et al. Stimulation and recording from regenerated peripheral nerves through polyimide sieve electrodes. , 1998, Journal of the peripheral nervous system : JPNS.
[49] E. Schutter,et al. Miniature carrier with six independently moveable electrodes for recording of multiple single-units in the cerebellar cortex of awake rats , 1999, Journal of Neuroscience Methods.
[50] Sidarta Ribeiro,et al. Multielectrode recordings: the next steps , 2002, Current Opinion in Neurobiology.
[51] John P. Donoghue,et al. Connecting cortex to machines: recent advances in brain interfaces , 2002, Nature Neuroscience.
[52] J. Prechtl,et al. Visual motion induces synchronous oscillations in turtle visual cortex. , 1994, Proceedings of the National Academy of Sciences of the United States of America.
[53] K. Wise,et al. An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.
[54] Yinghui Zhong,et al. Controlled release of anti-inflammatory agent alpha-MSH from neural implants. , 2005, Journal of controlled release : official journal of the Controlled Release Society.
[55] R. Laprade,et al. Electrical properties of glass microelectrodes , 1968 .
[56] Ravi V. Bellamkonda,et al. Controlled release of anti-inflammatory agent alpha-MSH from neural implants. , 2005, Journal of controlled release : official journal of the Controlled Release Society.
[57] D. Robinson,et al. The electrical properties of metal microelectrodes , 1968 .
[58] U. Hofmann,et al. Institute of Physics Publishing Journal of Micromechanics and Microengineering a 32-site Neural Recording Probe Fabricated by Drie of Soi Substrates , 2022 .
[59] R. Andersen,et al. Magnetic resonance image-guided implantation of chronic recording electrodes in the macaque intraparietal sulcus , 2003, Journal of Neuroscience Methods.
[60] P. Renaud,et al. Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. , 2004, Biosensors & bioelectronics.
[61] R. Hampson,et al. The significance of neural ensemble codes during behavior and cognition. , 1997, Annual review of neuroscience.
[62] E. Valderrama,et al. Polyimide cuff electrodes for peripheral nerve stimulation , 2000, Journal of Neuroscience Methods.
[63] Miguel A. L. Nicolelis,et al. Brain–machine interfaces to restore motor function and probe neural circuits , 2003, Nature Reviews Neuroscience.
[64] B L McNaughton,et al. Dynamics of the hippocampal ensemble code for space. , 1993, Science.
[65] H. Oka,et al. A new planar multielectrode array for extracellular recording: application to hippocampal acute slice , 1999, Journal of Neuroscience Methods.
[66] D. Kleinfeld,et al. Visual stimuli induce waves of electrical activity in turtle cortex. , 1997, Proceedings of the National Academy of Sciences of the United States of America.
[67] Alberto Prieto,et al. Microelectronics for Neural, Fuzzy and Bio-inspired Systems , 1999 .
[68] Alyssa Panitch,et al. Polymeric biomaterials for tissue and organ regeneration , 2001 .
[69] Miguel A. L. Nicolelis,et al. Methods for Neural Ensemble Recordings , 1998 .
[70] T K Chowdhury,et al. Fabrication of extremely fine glass micropipette electrodes. , 1969, Journal of scientific instruments.
[71] R. J. Vetter,et al. Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[72] Philippe M. Fauchet,et al. Porous silicon as a cell interface for bone tissue engineering , 2007 .
[73] K. Najafi,et al. A low-noise demultiplexing system for active multichannel microelectrode arrays , 1991, IEEE Transactions on Biomedical Engineering.
[74] Thomas M Pearce,et al. Microtechnology: meet neurobiology. , 2007, Lab on a chip.
[75] Kensall D. Wise,et al. Low-voltage electronics for the stimulation of biological neural networks using fully complementary BiCMOS circuits , 1997, IEEE J. Solid State Circuits.
[76] Kensall D. Wise,et al. A 16-channel CMOS neural stimulating array , 1992 .
[77] Luke P. Lee,et al. A new neural probe using SOI wafers with topological interlocking mechanisms , 2000, 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451).
[78] Masahiko Hara,et al. A new planar multielectrode array: recording from a rat auditory cortex , 2006, Journal of neural engineering.
[79] J. Skrzypek,et al. Manufacture of Metal Microelectrodes with the Scanning Electron Microscope , 1975, IEEE Transactions on Biomedical Engineering.
[80] Jack W. Judy,et al. Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process , 2005, IEEE Transactions on Biomedical Engineering.
[81] James M. Bower,et al. Plasma-etched neural probes , 1996 .
[82] A. B. Frazier,et al. Two dimensional metallic microelectrode arrays for extracellular stimulation and recording of neurons , 1993, [1993] Proceedings IEEE Micro Electro Mechanical Systems.
[83] Karen A. Moxon,et al. Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface , 2004, IEEE Transactions on Biomedical Engineering.
[84] A. Huxley,et al. Hodgkin and the action potential 1935–1952 , 2002, The Journal of physiology.
[85] C. Terzuolo,et al. AN ANALYSIS OF INTRA‐ VERSUS EXTRACELLULAR POTENTIAL CHANGES ASSOCIATED WITH ACTIVITY OF SINGLE SPINAL MOTONEURONS * , 1961, Annals of the New York Academy of Sciences.
[86] W. Balachandran,et al. Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers , 2000, Medical and Biological Engineering and Computing.
[87] Marcus Granmo,et al. An imaging system for monitoring receptive field dynamics , 2001, Journal of Neuroscience Methods.
[88] I. K. Wood,et al. Neuroscience: Exploring the brain , 1996 .
[89] D. J. Warren,et al. A neural interface for a cortical vision prosthesis , 1999, Vision Research.
[90] K. Wise,et al. A planar IrO multichannel stimulating electrode for use in neural prostheses , 1990 .
[91] N K Wood,et al. The significance of implant shape in experimental testing of biological materials: disc vs. rod. , 1970, Journal of biomedical materials research.
[92] K. Horch,et al. A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.
[93] S. R. Taylor,et al. Effect of surface texture on the soft tissue response to polymer implants. , 1983, Journal of biomedical materials research.
[94] R. Andersen,et al. A floating metal microelectrode array for chronic implantation , 2007, Journal of Neuroscience Methods.
[95] D. Hubel,et al. Ferrier lecture - Functional architecture of macaque monkey visual cortex , 1977, Proceedings of the Royal Society of London. Series B. Biological Sciences.
[96] Thomas Stieglitz,et al. Flexible, polyimide-based neural interfaces , 1999, Proceedings of the Seventh International Conference on Microelectronics for Neural, Fuzzy and Bio-Inspired Systems.
[97] P. Kennedy. The cone electrode: a long-term electrode that records from neurites grown onto its recording surface , 1989, Journal of Neuroscience Methods.
[98] K D Wise,et al. Microfabrication techniques for integrated sensors and microsystems. , 1991, Science.
[99] W. Reichert,et al. Polyimides as biomaterials: preliminary biocompatibility testing. , 1993, Biomaterials.
[100] K. Najafi,et al. Scaling limitations of silicon multichannel recording probes , 1990, IEEE Transactions on Biomedical Engineering.
[101] K. Wise,et al. A three-dimensional microelectrode array for chronic neural recording , 1994, IEEE Transactions on Biomedical Engineering.
[102] Luke P. Lee,et al. Implantable multichannel electrode array based on SOI technology , 2003 .
[103] Philippe M. Fauchet,et al. Nano‐ to Microscale Porous Silicon as a Cell Interface for Bone‐Tissue Engineering , 2007 .
[104] Andreas Maciossek. Electrodeposition of 3D microstructures without molds , 1996, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.
[105] K. Wise,et al. Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity , 1988, IEEE Transactions on Biomedical Engineering.
[106] K. Wise,et al. A silicon probe with integrated microheaters for thermal marking and monitoring of neural tissue , 1997, IEEE Transactions on Biomedical Engineering.
[107] Derrick Dean,et al. Nanostructured Biomaterials for Regenerative Medicine , 2006 .
[108] P. Latham,et al. Population coding in the retina , 1998, Current Opinion in Neurobiology.
[109] A. Hodgkin,et al. A quantitative description of membrane current and its application to conduction and excitation in nerve , 1952, The Journal of physiology.
[110] Justin C. Williams,et al. Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.
[111] C. Gilbert. Adult cortical dynamics. , 1998, Physiological reviews.
[112] Qing Bai,et al. A high-yield microassembly structure for three-dimensional microelectrode arrays , 2000, IEEE Transactions on Biomedical Engineering.
[113] T. Stieglitz,et al. Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .
[114] Wamadeva Balachandran,et al. Microengineered interfaces with the nervous system , 1996 .
[115] W. Rutten. Selective electrical interfaces with the nervous system. , 2002, Annual review of biomedical engineering.
[116] B Bioulac,et al. Minimal tissue damage after stimulation of the motor thalamus in a case of chorea-acanthocytosis , 2002, Neurology.
[117] H. K. Charles,et al. Multisite microprobes for neural recordings , 1991, IEEE Transactions on Biomedical Engineering.
[118] B L McNaughton,et al. Coordinated Reactivation of Distributed Memory Traces in Primate Neocortex , 2002, Science.
[119] R. Shapley,et al. A neuronal network model of macaque primary visual cortex (V1): orientation selectivity and dynamics in the input layer 4Calpha. , 2000, Proceedings of the National Academy of Sciences of the United States of America.
[120] S. Retterer,et al. Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex , 2005, Experimental Neurology.
[121] R. Normann,et al. Chronic recordings of visually evoked responses using the utah intracortical electrode array , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.
[122] T. Stieglitz. Flexible biomedical microdevices with double-sided electrode arrangements for neural applications , 2001 .
[123] E. Schmidt,et al. Laser exposure of Parylene-C insulated microelectrodes , 1995, Journal of Neuroscience Methods.
[124] K. E. Jones,et al. A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.
[125] M. Diamond,et al. Spatial–Temporal Distribution of Whisker-Evoked Activity in Rat Somatosensory Cortex and the Coding of Stimulus Location , 2000, The Journal of Neuroscience.