Discriminant analysis of native thoracic aortic curvature: risk prediction for endoleak formation after thoracic endovascular aortic repair.

PURPOSE To determine the association of native thoracic aortic curvature measured from computed tomographic (CT) angiography categorized by discriminant analysis with the development of endoleaks after thoracic endovascular aortic repair (EVAR). MATERIALS AND METHODS Forty patients (28 men, 12 women; mean age, 74 y; range, 40-89 y) with aortic diseases treated with thoracic EVAR were evaluated. Diseases treated included atherosclerotic aneurysm (n = 27), penetrating atherosclerotic ulcer (n = 4), intramural hematoma (n = 3), mycotic aneurysm (n = 3), and anastomotic pseudoaneurysm (n = 3). Quantitative analysis of native aortic morphology was performed on preprocedural CT angiograms with an original customized computer program, and regional curvature indices in each anatomic segment of the aorta were calculated. Patterns of native thoracic aortic morphology were analyzed by discriminant analysis. The association between the morphologic pattern of the aorta and the presence and type of endoleak was assessed. RESULTS After leave-one-out cross-validation methods had been applied, the sensitivity, specificity, and accuracy to detect endoleak formation in a new population group by discriminant analysis of the patterns of native aortic curvature were estimated as 84.0%, 58.8%, and 73.8%, respectively. Compared with the no-endoleak group, the type Ia endoleak group had greater curvature at the aortic arch, the type Ib endoleak group had greater curvature at the thoracoabdominal junction, and the type III endoleak group had greater curvature in the midportion of the descending aorta. CONCLUSIONS Discriminant analysis of native thoracic aortic morphology measured from CT angiography is a useful tool to predict the risk of endoleak formation after thoracic EVAR and should be implemented during treatment planning and follow-up.

[1]  D. Fleischmann,et al.  Clinical 3D and 4D Imaging of the Thoracic Aorta , 2007 .

[2]  B. Lytle,et al.  Endovascular repair of thoracic aortic lesions with the Zenith TX1 and TX2 thoracic grafts: intermediate-term results. , 2005, Journal of vascular surgery.

[3]  D S Paik,et al.  Automated flight path planning for virtual endoscopy. , 1998, Medical physics.

[4]  P Bergeron,et al.  Identification of proximal landing zone limit for proper deployment of aortic arch stentgraft after supra-aortic great vessels transposition. , 2007, The Journal of cardiovascular surgery.

[5]  D S Paik,et al.  Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. , 2001, Radiology.

[6]  M. Eskandari,et al.  Endovascular repair of thoracic aortic tears. , 2006, The Annals of thoracic surgery.

[7]  D. Obrand,et al.  The Proximal Landing Zone in Endovascular Repair of the Thoracic Aorta , 2004, Annals of vascular surgery.

[8]  Rodney A. White,et al.  Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. , 2002, Journal of vascular surgery.

[9]  Jarrett Rosenberg,et al.  Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic Dissection , 2009, Circulation. Cardiovascular interventions.

[10]  J. Bavaria,et al.  Endoleaks after endovascular repair of thoracic aortic aneurysms. , 2006, Journal of vascular surgery.

[11]  Luigi de Luca Tupputi Schinosa,et al.  Endovascular Treatment of Thoracic Aortic Disease: Four Years of Experience , 2004, Circulation.

[12]  R. S. Mitchell,et al.  Expert consensus document on the treatment of descending thoracic aortic disease using endovascular stent-grafts. , 2008, The Annals of thoracic surgery.

[13]  R. Fisher THE USE OF MULTIPLE MEASUREMENTS IN TAXONOMIC PROBLEMS , 1936 .

[14]  Maciej Banach,et al.  Predictive factors for endoleaks after thoracic aortic aneurysm endograft repair. , 2009, The Journal of thoracic and cardiovascular surgery.

[15]  J. Hodler,et al.  Diseases of the Heart, Chest & Breast , 2007 .

[16]  J. Bavaria,et al.  Thoracic aortic stent grafting: improving results with newer generation investigational devices. , 2006, The Journal of thoracic and cardiovascular surgery.

[17]  D S Paik,et al.  Measurement of the aorta and its branches with helical CT. , 1998, Radiology.

[18]  Takuya Ueda,et al.  Incomplete endograft apposition to the aortic arch: bird-beak configuration increases risk of endoleak formation after thoracic endovascular aortic repair. , 2010, Radiology.

[19]  G. Rubin,et al.  Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. , 2001, Journal of vascular surgery.

[20]  C. Nienaber,et al.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. , 1999, The New England journal of medicine.

[21]  M. Czerny,et al.  Results After Endovascular Stent Graft Placement in Atherosclerotic Aneurysms Involving the Descending Aorta , 2007 .

[22]  R. S. Mitchell,et al.  Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts. , 2004, The Journal of thoracic and cardiovascular surgery.

[23]  R. S. Mitchell,et al.  Complicated acute type B aortic dissection: midterm results of emergency endovascular stent-grafting. , 2008, The Journal of thoracic and cardiovascular surgery.

[24]  K. Harris,et al.  Endovascular Repair of Thoracic Aortic Disease: Early and Midterm Experience , 2007, Vascular and endovascular surgery.

[25]  S. Pizer,et al.  Measuring tortuosity of the intracerebral vasculature from MRA images , 2003, IEEE Transactions on Medical Imaging.

[26]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[27]  Pierre Conort,et al.  Helical CT evaluation of the chemical composition of urinary tract calculi with a discriminant analysis of CT-attenuation values and density , 2004, European Radiology.