Arrhythmia detection by dual-chamber implantable cardioverter defibrillators. A review of current algorithms.

This article reviews the arrhythmia detection criteria currently available in dual-chamber implantable cardioverter defibrillators (ICDs), and describes the implementation and performance of various detection algorithms. Nearly all criteria implemented in single-chamber devices appear to have been included in dual-chamber ICDs. However, two different strategies can be distinguished: the first adds dual-chamber inhibition criteria to a single-chamber detection configuration; the second is a new approach entirely based on a dual-chamber detection scheme. Despite widely available clinical data, an analysis of the implemented detection indexes, arrhythmia characteristics (induced vs spontaneous, minimum duration), device programming (detection rate, programme maintenance and tuning during follow-up), and different storage capabilities among various ICD models, leaves the results of these studies ultimately ambiguous. New algorithms are under study, but only protocols using a single set of arrhythmias and the same programming for all devices may allow relevant comparisons of the performances of detection algorithms. Furthermore, a criterion is required to distinguish reliably between haemodynamically stable and unstable tachycardias, not simply based on rate, but including the underlying cardiac function.

[1]  C. Unterberg,et al.  Programmierungsoptimierung der sustained rate duration bei Patienten mit implantierbarem Cardioverter-Defibrillator und bekanntem Vorhofflimmern , 1999, Zeitschrift für Kardiologie.

[2]  G. Boriani,et al.  Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators , 2001, Pacing and clinical electrophysiology : PACE.

[3]  W. Tacker Defibrillation of the heart : ICDs, AEDs, and manual , 1994 .

[4]  R. Luceri Initial Clinical Experience with a Dual Chamber Rate Responsive Implantable Cardioverter Defibrillator , 2000, Pacing and clinical electrophysiology : PACE.

[5]  C. Israel,et al.  Discrimination Between Ventricular and Supraventricular Tachycardia by Dual Chamber Cardioverter Defibrillators: Importance of the Atrial Sensing Function , 2001, Pacing and clinical electrophysiology : PACE.

[6]  R. Vonthein,et al.  Enhanced Detection Criteria in Implantable Cardioverter Defibrillators: Sensitivity and Specificity of the Stability Algorithm at Different Heart Rates , 2001, Pacing and clinical electrophysiology : PACE.

[7]  M. Mirowski,et al.  Considerations in the development of the automatic implantable defibrillator. , 1976, Medical instrumentation.

[9]  G. Breithardt,et al.  RR interval variability in irregular monomorphic ventricular tachycardia and atrial fibrillation. , 1996, Circulation.

[10]  Antonio Artés-Rodríguez,et al.  Automatic Discrimination Between Supraventricular and Ventricular Tachycardia Using a Multilayer Perceptron in Implantable Cardioverter Defibrillators , 2002, Pacing and clinical electrophysiology : PACE.

[11]  B Letac,et al.  Automatic arrhythmia identification using analysis of the atrioventricular association. Application to a new generation of implantable defibrillators. Participating Centers of the Automatic Recognition of Arrhythmia Study Group. , 1997, Circulation.

[12]  T. Lüscher,et al.  The Potential for Inappropriate Ventricular Tachycardia Confirmation Using the Intracardiac Electrogram (EGM) Width Criterion , 1999, Pacing and clinical electrophysiology : PACE.

[13]  Jeffrey M. Gillberg,et al.  Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection : results and technical considerations. , 2001 .

[14]  A. Vinet,et al.  Underdetection of Ventricular Tachycardia Using a 40 ms Stability Criterion: Effect of Antiarrhythmic Therapy , 1997, Pacing and clinical electrophysiology : PACE.

[15]  M. Rahn-Schönbeck,et al.  Morphology Discriminator Feature for Enhanced Ventricular Tachycardia Discrimination in Implantable Cardioverter Defibrillators , 2000, Pacing and clinical electrophysiology : PACE.

[16]  E. Gang,et al.  Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator. , 1994, Journal of the American College of Cardiology.

[17]  P. S. Chen,et al.  Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator. , 1994, Journal of the American College of Cardiology.

[18]  S. Hohnloser,et al.  First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator. Advantages and complications. The Ventak AV II DR investigators. , 1999, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[19]  N. Sheth,et al.  Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators. , 2000, Circulation.

[20]  V. Kühlkamp,et al.  Clinical Experience with the New Detection Algorithms for Atrial Fibrillation of a Defibrillator with Dual Chamber Sensing and Pacing , 1999, Journal of cardiovascular electrophysiology.

[21]  K. Stein,et al.  Worldwide Clinical Experience with a New Dual‐Chamber Implantable Cardioverter Defibrillator System , 2001, Journal of cardiovascular electrophysiology.

[22]  G. Boriani,et al.  Rhythm Discrimination by Rate Branch and QRS Morphology in Dual Chamber Implantable Cardioverter Defibrillators , 2003, Pacing and clinical electrophysiology : PACE.

[23]  Walter H Olson,et al.  Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet‐Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms , 2002, Journal of cardiovascular electrophysiology.

[24]  J. Davy,et al.  Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia. , 2004, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[25]  S. Hohnloser,et al.  Intracardiac QRS Electrogram Width—An Arrhythmia Detection Feature for Implantable Cardioverter Defibrillators: Exercise Induced Variation as a Base for Device Programming , 1998, Pacing and clinical electrophysiology : PACE.

[26]  P. Albert,et al.  Models for longitudinal data: a generalized estimating equation approach. , 1988, Biometrics.

[27]  J. Roelandt,et al.  Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators. , 2001, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[28]  M. Gold,et al.  Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation , 2002, Journal of cardiovascular electrophysiology.

[29]  J. Daubert,et al.  Preliminary Clinical Experience with the First Dual Chamber Pacemaker Defibrillator , 1997, Pacing and clinical electrophysiology : PACE.

[30]  M. Kroll,et al.  Energy Steering of Biphasic Waveforms Using a Transvenous Three Electrode System , 1999, Pacing and clinical electrophysiology : PACE.

[31]  M. Niebauer,et al.  Clinical Investigation of a New Dual‐Chamber Implantable Cardioverter Defibrillator with Improved Rhythm Discrimination Capabilities , 2003, Journal of cardiovascular electrophysiology.

[32]  J. Jenkins,et al.  Identification of Ventricular Tachycardia Using Intracavitary Ventricular Electrograms: Analysis of Time and Frequency Domain Patterns , 1988, Pacing and clinical electrophysiology : PACE.

[33]  H. Wellens,et al.  Dual Chamber Arrhythmia Detection in the Implantable Cardioverter Defibrillator , 2000, Journal of cardiovascular electrophysiology.

[34]  A. Galati,et al.  Electrogram Width Parameter Analysis in Implantable Cardioverter Defibrillators: Influence of Body Position and Electrode Configuration , 2001, Pacing and clinical electrophysiology : PACE.

[35]  R Arzbaecher,et al.  A Single Atrial Extrastimulus Can Distinguish Sinus Tachycardia from 1:1 Paroxysmal Tachycardia , 1986, Pacing and clinical electrophysiology : PACE.

[36]  L. Liem,et al.  Mixed venous oxygen saturation for differentiating stable from unstable tachycardias. , 1991, American heart journal.

[37]  G. Kaye,et al.  Tachycardia Recognition and Diagnosis from Changes in Right Atrial Pressure Waveform—A Feasibility Study , 1991, Pacing and clinical electrophysiology : PACE.

[38]  L. Jordaens,et al.  Diagnostic Performance of a Dual‐Chamber Cardioverter Defibrillator Programmed with Nominal Settings: A European Prospective Study , 2002, Cardiovascular Electrophysiology.

[39]  M. Gold,et al.  Clinical Experience with a Dual‐Chamber Implantable Cardioverter Defibrillator to Treat Atrial Tachyarrhythmias , 2001, Journal of cardiovascular electrophysiology.

[40]  O. Pachinger,et al.  Inappropriate Detection of Supraventricular Arrhythmias by Implantable Dual Chamber Defibrillators: A Comparison of Four Different Algorithms , 2001, Pacing and clinical electrophysiology : PACE.

[41]  J. M. Jenkins,et al.  Detection algorithms in implantable cardioverter defibrillators , 1996, Proc. IEEE.

[42]  G. Hasenfuss,et al.  Long‐Term Clinical Experience with the EGM Width Detection Criterion for Differentiation of Supraventricular and Ventricular Tachycardia in Patients with Implantable Cardioverter Defibrillators , 2000, Pacing and clinical electrophysiology : PACE.

[43]  J. Brugada,et al.  Enhanced Detection Criteria in Implantable Defibrillators , 1998, Journal of cardiovascular electrophysiology.