Analysis and Design of a linearization Current Control Strategy for Three-Phase Voltage-Source PWM Converter

This paper establishes a linearization current control mathematical model with fixed switching frequency for three-phase pulse width modulated (PWM) converter. The input currents are decoupling controlled in the stationary reference frame. The paper proposes a design method of inductance in AC side and voltage in DC side of main circuit. Based on the models of converter, the design method of controller is obtained. Meanwhile, the factors that influence input current harmonic are analyzed. A prototype has been implemented. The experimental results demonstrate that the designed converter has bidirectional power transmission ability with good dynamic performance. It also has the advantages of unity input power factor and low input current harmonic distortion.

[1]  E. Gaio,et al.  Improved current control technique for VSI PWM inverters with constant modulation frequency and extended voltage range , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[2]  Thomas G. Habetler,et al.  A space vector-based rectifier regulator for AC/DC/AC converters , 1993 .

[3]  R. Wu,et al.  A PWM AC to DC converter with fixed switching frequency , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[4]  Donald Grahame Holmes,et al.  A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[5]  Ned Mohan,et al.  Adaptive tolerance-band current control of standby power supply provides load-current harmonic neutralization , 1992, PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference.

[6]  Hirofumi Akagi,et al.  A new power line conditioner for harmonic compensation in power systems , 1995 .

[7]  A. Zuccato,et al.  Digital adaptive hysteresis current control with clocked commutations and wide operating range , 1994 .

[8]  W. Mcmurray,et al.  Modulation of the Chopping Frequency in DC Choppers and PWM Inverters Having Current-Hysteresis Controllers , 1983, IEEE Transactions on Industry Applications.

[9]  S. B. Dewan,et al.  Analysis of a PWM AC to DC voltage source converter under the predicted current control with a fixed switching frequency , 1991 .

[10]  István Nagy Novel adaptive tolerance band based PWM for field-oriented control of induction machines , 1994, IEEE Trans. Ind. Electron..

[11]  Boon-Teck Ooi,et al.  Voltage angle lock loop control of the boost type PWM converter for HVDC application , 1990 .

[12]  Tae-Won Chun,et al.  Development of adaptive hysteresis band current control strategy of PWM inverter with constant switching frequency , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[13]  Ting-Yu Chang,et al.  An improved hysteresis current controller for reducing switching frequency , 1994 .