Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction

We propose a pinhole-based fluorescent x-ray computed tomography (p-FXCT) system with a 2-D detector and volumetric beam that can suppress the quality deterioration caused by scatter components. In the corresponding p-FXCT technique, projections are acquired at individual incident energies just above and below the K-edge of the imaged trace element; then, reconstruction is performed based on the two sets of projections using a maximum likelihood expectation maximization algorithm that incorporates the scatter components. We constructed a p-FXCT imaging system and performed a preliminary experiment using a physical phantom and an I imaging agent. The proposed dual-energy p-FXCT improved the contrast-to-noise ratio by a factor of more than 2.5 compared to that attainable using mono-energetic p-FXCT for a 0.3 mg/ml I solution. We also imaged an excised rat’s liver infused with a Ba contrast agent to demonstrate the feasibility of imaging a biological sample.

[1]  Guillem Pratx,et al.  X-Ray Luminescence and X-Ray Fluorescence Computed Tomography: New Molecular Imaging Modalities , 2014, IEEE Access.

[2]  Tetsuya Yuasa,et al.  X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice. , 2009, Journal of synchrotron radiation.

[3]  Tetsuya Yuasa,et al.  Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .

[4]  S. Meikle,et al.  Small animal SPECT and its place in the matrix of molecular imaging technologies , 2005, Physics in medicine and biology.

[5]  Tetsuya Yuasa,et al.  The feasibility study on 3-dimensional fluorescent x-ray computed tomography using the pinhole effect for biomedical applications , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[6]  Kentaro Uesugi,et al.  Confocal full-field X-ray microscope for novel three-dimensional X-ray imaging. , 2009, Journal of synchrotron radiation.

[7]  B. Jones,et al.  Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams , 2012, Physics in medicine and biology.

[8]  Tetsuya Yuasa,et al.  Visualization of age-dependent myocardial metabolic impairment in cardiomyopathic model hamster obtained by fluorescent X-ray computed tomography using I-127 BMIPP. , 2008, Journal of synchrotron radiation.

[9]  L. Grodzins,et al.  Fluorescence tomography using synchrotron radiation at the NSLS , 1987 .

[10]  Michele Larobina,et al.  Small Animal PET: A Review of Commercially Available Imaging Systems , 2006 .

[11]  Brendan Vastenhouw,et al.  Pixel-based subsets for rapid multi-pinhole SPECT reconstruction , 2010, Physics in medicine and biology.

[12]  Brendan Vastenhouw,et al.  Targeted multi-pinhole SPECT , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  Thet-Thet-Lwin,et al.  Preliminary quantitative analysis of myocardial fatty acid metabolism from fluorescent X-ray computed tomography imaging. , 2007, Journal of synchrotron radiation.

[14]  Roberto Cesareo,et al.  A new tomographic device based on the detection of fluorescent x-rays , 1989 .

[15]  Enzo Lombi,et al.  Synchrotron-based techniques for plant and soil science: opportunities, challenges and future perspectives , 2009, Plant and Soil.

[16]  Tetsuya Yuasa,et al.  Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator , 1996, Medical Imaging.

[17]  M. Khalil,et al.  Molecular SPECT Imaging: An Overview , 2011, International journal of molecular imaging.

[18]  Tetsuya Yuasa,et al.  Sheet-beam geometry for in vivo fluorescent x-ray computed tomography: proof-of-concept experiment in molecular imaging. , 2008, Optics letters.

[19]  M. Chukalina,et al.  Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography , 2003 .

[20]  C. Schroer Reconstructing x-ray fluorescence microtomograms , 2001 .

[21]  F. Liu,et al.  X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays , 2010, Physics in medicine and biology.

[22]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[23]  Tohoru Takeda Preliminary experiment of the fluorescent X-ray computed tomography with synchrotron radiation , 1994 .

[24]  Q. Huo,et al.  FIRST EXPERIMENTAL RESULT WITH FLUORESCENT X-RAY CT BASED ON SHEET-BEAM GEOMETRY , 2009 .

[25]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[26]  S. Riederer,et al.  Digital K-edge subtraction radiography. , 1977, Radiology.

[27]  Tetsuya Yuasa,et al.  Fluorescent x-ray computed tomography using the pinhole effect for biomedical applications , 2013 .

[28]  R. Gonsalves,et al.  Fluorescent computer tomography: a model for correction of X-ray absorption , 1991 .