Current Control of Grid-Connected Inverter With LCL Filter Based on Extended-State Observer Estimations Using Single Sensor and Achieving Improved Robust Observation Dynamics

In the context of distributed generation and renewable energy penetration toward smart grid, grid-connected inverter with LCL filter has drawn many attentions, whose current control conventionally requires several sensors to realize active damping and grid synchronization. In this paper, a novel full status observation strategy based on extended state observer (ESO) is proposed using inverter current feedback only and without grid voltage sensor. The proposed observation strategy contains observation and transformation process. Unlike conventional Luenberger observer, by using ESO, the system parameters do not appear in observation process, thus the observer dynamics and parameter mismatch error can be separately handled, providing more robust observation dynamics during parameter variation. Parameter mismatch study was carried out, and it is found that purposely choosing the observer parameters smaller than the real value can achieve relatively low estimation error and a large adaption range for parameter variation. The proposed observation strategy is simple to implement, without the need of expert knowledge-based parameter tuning such as pole placement. Experimental tests validated that the proposed observation-based control is able to give satisfactory performance in both dynamic and steady states, as well as adaption for system parameter variation.

[1]  Dianguo Xu,et al.  Weight-Transducerless Rollback Mitigation Adopting Enhanced MPC With Extended State Observer for Direct-Drive Elevators , 2016, IEEE Transactions on Power Electronics.

[2]  Frede Blaabjerg,et al.  Virtual RC Damping of LCL-Filtered Voltage Source Converters With Extended Selective Harmonic Compensation , 2015, IEEE Transactions on Power Electronics.

[3]  Marco Liserre,et al.  Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters , 2014, IEEE Transactions on Industrial Informatics.

[4]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[5]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[6]  Dong Xu,et al.  Missile Guidance Law Based on Extended State Observer , 2013, IEEE Transactions on Industrial Electronics.

[7]  Han Jing-qing Parameters of the Extended State Observer and Fibonacci Sequence , 2008 .

[8]  Steffan Hansen,et al.  Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.

[9]  Yi Huang,et al.  ADRC With Adaptive Extended State Observer and its Application to Air–Fuel Ratio Control in Gasoline Engines , 2015, IEEE Transactions on Industrial Electronics.

[10]  Vlatko Miskovic,et al.  Observer based active damping of LCL resonance in grid connected voltage source converters , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[11]  Mariusz Malinowski,et al.  A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter , 2008, IEEE Transactions on Industrial Electronics.

[12]  Frede Blaabjerg,et al.  Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters , 2016, IEEE Transactions on Power Electronics.

[13]  Jorge A. Solsona,et al.  Full-State Feedback Equivalent Controller for Active Damping in $LCL$-Filtered Grid-Connected Inverters Using a Reduced Number of Sensors , 2015, IEEE Transactions on Industrial Electronics.

[14]  Zongxia Jiao,et al.  Extended-State-Observer-Based Output Feedback Nonlinear Robust Control of Hydraulic Systems With Backstepping , 2014, IEEE Transactions on Industrial Electronics.

[15]  Marko Hinkkanen,et al.  Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter , 2014, IEEE Transactions on Industry Applications.

[16]  Zongxia Jiao,et al.  Adaptive Robust Control of DC Motors With Extended State Observer , 2014, IEEE Transactions on Industrial Electronics.

[17]  Pekik Argo Dahono A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[18]  Johan Driesen,et al.  Model-based generation of low distortion currents in grid-coupled PWM-inverters using an LCL output filter , 2006, IEEE Transactions on Power Electronics.

[19]  Frede Blaabjerg,et al.  A Self-commissioning Notch Filter for Active Damping in a Three-Phase LCL -Filter-Based Grid-Tie Converter , 2014, IEEE Transactions on Power Electronics.

[20]  Frede Blaabjerg,et al.  Highly Accurate Derivatives for LCL-Filtered Grid Converter With Capacitor Voltage Active Damping , 2016, IEEE Transactions on Power Electronics.

[21]  Thomas M. Jahns,et al.  Observer-Based Active Damping of $LCL$ Resonance in Grid-Connected Voltage Source Converters , 2014 .

[22]  Marko Hinkkanen,et al.  Observer-based state-space current control for a three-phase grid-connected converter equipped with an LCL filter , 2014 .

[23]  Manfred Morari,et al.  Explicit Model-Predictive Control of a PWM Inverter With an LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[24]  Bin Yang,et al.  Extended-State-Observer-Based Double-Loop Integral Sliding-Mode Control of Electronic Throttle Valve , 2015, IEEE Transactions on Intelligent Transportation Systems.

[25]  Jingqing Han,et al.  From PID to Active Disturbance Rejection Control , 2009, IEEE Trans. Ind. Electron..