Repeatability of electrically evoked EMG signals in the human vastus medialis muscle

The repeatability of spectral and amplitude parameters and conduction velocity estimates of M‐waves was tested on the vastus medialis muscle of 9 normal subjects. Isometric contractions sustained for 30 s were elicited by stimulation of the main muscle motor point and repeated on 5 different days. The initial value and two indicators of myoelectric manifestations of muscle fatigue were computed for each variable. The test—retest Pearson correlation coefficient, the paired Wilcoxon test, and the intraclass correlation coefficient (ICC) showed that parameters of spectral variables are more repeatable than those of amplitude variables and conduction velocity. The ICC ranged from 86.4% for the initial value of median frequency to 21.6% for the initial value of the average rectified value. Fatigue indices showed ICCs in the range of 20–64%. It is concluded that: (a) initial values and fatigue indices based on spectral variables are more repeatable than those based on amplitude variables; (b) the repeatability of conduction velocity estimates is not yet sufficient for clinical application; (c) M‐wave shape, rather than amplitude or width, is a characteristic of individual muscles; and (d) electrode location is critical. © 1998 John Wiley & Sons, Inc. Muscle Nerve 21: 184–193, 1998.

[1]  D. Stegeman,et al.  Variability and interrelationships of surface EMG parameters during local muscle fatigue , 1993, Muscle & nerve.

[2]  R. Merletti,et al.  Suppression of stimulation artifacts from myoelectric-evoked potential recordings , 1988, IEEE Transactions on Biomedical Engineering.

[3]  R. Merletti,et al.  Repeatability of electrically-evoked myoelectric signals in the human tibialis anterior muscle. , 1995, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[4]  R. Merletti,et al.  Hermite expansions of compact support waveforms: applications to myoelectric signals , 1994, IEEE Transactions on Biomedical Engineering.

[5]  J. Bartko The Intraclass Correlation Coefficient as a Measure of Reliability , 1966, Psychological reports.

[6]  H J Biedermann A method for assessing the equivalence of repeated measures of muscle fatigue rates estimated from EMG power spectrum analysis. , 1991, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[7]  R Merletti,et al.  Indices of muscle fatigue. , 1991, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[8]  T A Wilson,et al.  Model for a pump that drives circulation of pleural fluid. , 1995, Journal of applied physiology.

[9]  R Kadefors,et al.  Variability of the EMG mean power frequency: A study on the trapezius muscle. , 1991, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  C. D. De Luca,et al.  Effects of muscle fiber type and size on EMG median frequency and conduction velocity. , 1995, Journal of applied physiology.

[11]  Roberto Merletti,et al.  Electrically evoked myoelectric signals in back muscles : effect of side dominance , 1994 .