A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry.

Selected-ion flow-tube mass spectrometry (SIFT-MS) has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 male, 11 female) over a 6-month period. Volunteers provided breath samples each week between 8:45 and 13:00 (before lunch), and the concentrations of several trace compounds were obtained. In this paper the focus is on ethanol and acetaldehyde, which were simultaneously quantified by SIFT-MS using H3O+ precursor ions. The mean ethanol level for all samples was 196 parts-per-billion (ppb) with a standard deviation of 244 ppb, and the range of values for breath samples analysed is 0 to 1663 ppb. The mean acetaldehyde level for all samples was 24 ppb with a standard deviation of 17 ppb, and the range of values for breath samples analysed is 0 to 104 ppb. Background (ambient air) levels of ethanol were around 50 ppb, whereas any background acetaldehyde was usually undetectable. Increased ethanol levels were observed if sweet drink/food had been consumed within the 2 h prior to providing the breath samples, but no increase was apparent when alcohol had been consumed the previous evening. The measured endogenous breath ethanol and acetaldehyde levels were not correlated. These data relating to healthy individuals are a prelude to using breath analysis for clinical diagnosis, for example, the recognition of bacterial overload in the gut (ethanol) or the possibly of detecting tumours in the body (acetaldehyde).

[1]  David Smith,et al.  Quantification of acetaldehyde released by lung cancer cells in vitro using selected ion flow tube mass spectrometry. , 2003, Rapid communications in mass spectrometry : RCM.

[2]  P. Španěl,et al.  The challenge of breath analysis for clinical diagnosis and therapeutic monitoring. , 2007, The Analyst.

[3]  P. Španěl,et al.  SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones , 1997 .

[4]  David Smith,et al.  Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. , 2005, Mass spectrometry reviews.

[5]  P. Španěl,et al.  Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath , 1996, Medical and Biological Engineering and Computing.

[6]  David M. Umulis,et al.  A physiologically based model for ethanol and acetaldehyde metabolism in human beings. , 2005, Alcohol.

[7]  G. Freund,et al.  Acetaldehyde concentrations in alveolar air following a standard dose of ethanol in man. , 1965, Journal of lipid research.

[8]  Patrik Španěl,et al.  Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air and on breath , 1996 .

[9]  K Geiger,et al.  Impact of inspired substance concentrations on the results of breath analysis in mechanically ventilated patients , 2005, Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals.

[10]  P. Španěl,et al.  Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study. , 1999, Journal of applied physiology.

[11]  S. Davies,et al.  Quantification of ammonia in human breath by the selected ion flow tube analytical method using H30+ and 02+ precursor ions. , 1998, Rapid communications in mass spectrometry : RCM.

[12]  J. Brien,et al.  Pharmacology of acetaldehyde. , 1983, Canadian journal of physiology and pharmacology.

[13]  David Smith,et al.  On-line, simultaneous quantification of ethanol, some metabolites and water vapour in breath following the ingestion of alcohol. , 2002, Physiological measurement.

[14]  C. Eriksson Human blood acetaldehyde concentration during ethanol oxidation (update 1982) , 1983, Pharmacology Biochemistry and Behavior.

[15]  A. Jones Measuring and reporting the concentration of acetaldehyde in human breath. , 1995, Alcohol and alcoholism.

[16]  David Smith,et al.  Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days. , 2003, Physiological measurement.