Usability Assessment of a Cable-Driven Exoskeletal Robot for Hand Rehabilitation

Study design: Case series. Background: Robot-assisted rehabilitation mediated by exoskeletal devices is a popular topic of research. The biggest difficulty in the development of rehabilitation robots is the consideration of the clinical needs. This study investigated the usability of a novel cable-driven exoskeletal robot specifically designed for hand rehabilitation. Methods: The study consists of three steps, including prototype development, spasticity observation, and usability evaluation. First, we developed the prototype robot DexoHand to manipulate the patient's fingers based on the clinical needs and the cable-driven concept established in our previous work. Second, we applied DexoHand to patients with different levels of spasticity. Finally, we obtained the system usability scale (SUS) and assessed its usability. Results: Two healthy subjects were recruited in the pre-test, and 18 patients with stroke and four healthy subjects were recruited in the formal test for usability. The total SUS score obtained from the patients and healthy subjects was 94.77 ± 2.98 (n = 22), indicating an excellent level of usability. The satisfaction score was 4.74 ± 0.29 (n = 22), revealing high satisfaction with DexoHand. The tension profile measured by the cables showed the instantaneous force used to manipulate fingers among different muscle tone groups. Conclusions: DexoHand meets the clinical needs with excellent usability, satisfaction, and reliable tension force monitoring, yielding a feasible platform for robot-assisted hand rehabilitation.

[1]  Won Hyuk Chang,et al.  Robot-assisted Therapy in Stroke Rehabilitation , 2013, Journal of stroke.

[2]  H. Feys,et al.  Effect of a therapeutic intervention for the hemiplegic upper limb in the acute phase after stroke: a single-blind, randomized, controlled multicenter trial. , 1998, Stroke.

[3]  A. Gordon,et al.  Efficacy of a hand–arm bimanual intensive therapy (HABIT) in children with hemiplegic cerebral palsy: a randomized control trial , 2007, Developmental medicine and child neurology.

[4]  Mao-Jiun Wang,et al.  Anthropometry-based structural design of a hand exoskeleton for rehabilitation , 2016, 2016 23rd International Conference on Mechatronics and Machine Vision in Practice (M2VIP).

[5]  J. B. Brooke,et al.  SUS: a retrospective , 2013 .

[6]  Nicola Smania,et al.  Effects of contralesional robot-assisted hand training in patients with unilateral spatial neglect following stroke: a case series study , 2014, Journal of NeuroEngineering and Rehabilitation.

[7]  Haruhisa Kawasaki,et al.  Development of a Hand-Assist Robot With Multi-Degrees-of-Freedom for Rehabilitation Therapy , 2012, IEEE/ASME Transactions on Mechatronics.

[8]  S.C. Cramer,et al.  A robotic device for hand motor therapy after stroke , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[9]  R. Teasell,et al.  The Role of Task-Specific Training in Rehabilitation Therapies , 2005, Topics in stroke rehabilitation.

[10]  Heidi Johansen-Berg,et al.  Structural Plasticity in Adulthood with Motor Learning and Stroke Rehabilitation. , 2018, Annual review of neuroscience.

[11]  M. Chen,et al.  An intention driven hand functions task training robotic system , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[12]  Robert C. Wagenaar,et al.  Therapy Impact on Functional Recovery in Stroke Rehabilitation , 1999 .

[13]  George Howard,et al.  Global stroke statistics , 2017, International journal of stroke : official journal of the International Stroke Society.

[14]  CinziaCalautti,et al.  Functional Neuroimaging Studies of Motor Recovery After Stroke in Adults , 2003 .

[15]  Ching-yi Wu,et al.  Constraint-Induced Therapy Versus Dose-Matched Control Intervention to Improve Motor Ability, Basic/Extended Daily Functions, and Quality of Life in Stroke , 2009, Neurorehabilitation and neural repair.

[16]  Francesco Giovacchini,et al.  HANDEXOS: Towards an exoskeleton device for the rehabilitation of the hand , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[17]  Antonia Tzemanaki,et al.  Development of a novel robotic system for hand rehabilitation , 2011, 2011 24th International Symposium on Computer-Based Medical Systems (CBMS).

[18]  Luca Padua,et al.  Robotic and Sensor Technology for Upper Limb Rehabilitation , 2018, PM & R : the journal of injury, function, and rehabilitation.

[19]  Rong Song,et al.  A Comparison Between Electromyography-Driven Robot and Passive Motion Device on Wrist Rehabilitation for Chronic Stroke , 2009, Neurorehabilitation and neural repair.

[20]  R. Likert “Technique for the Measurement of Attitudes, A” , 2022, The SAGE Encyclopedia of Research Design.

[21]  Andreas Wege,et al.  Development and control of a hand exoskeleton for rehabilitation of hand injuries , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[22]  Jing Wang,et al.  Hand Rehabilitation Robotics on Poststroke Motor Recovery , 2017, Behavioural neurology.

[23]  Kotaro Tadano,et al.  Development of grip amplified glove using bi-articular mechanism with pneumatic artificial rubber muscle , 2010, 2010 IEEE International Conference on Robotics and Automation.

[24]  Kyu-Jin Cho,et al.  Jointless structure and under-actuation mechanism for compact hand exoskeleton , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[25]  Paolo Dario,et al.  Wrist Robot-Assisted Rehabilitation Treatment in Subacute and Chronic Stroke Patients: From Distal-to-Proximal Motor Recovery , 2018, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  Daisuke Sasaki,et al.  Development of Soft Power-Assist Glove and Control Based on Human Intent , 2011, J. Robotics Mechatronics.

[27]  Shu-Wei Pu,et al.  A Robot-Assisted Hand Exoskeletal System for Mirror Therapy Rehabilitation , 2017 .

[28]  Stefano Negrini,et al.  Hand Passive Mobilization Performed with Robotic Assistance: Acute Effects on Upper Limb Perfusion and Spasticity in Stroke Survivors , 2017, BioMed research international.

[29]  K. Y. Tong,et al.  An EMG-driven exoskeleton hand robotic training device on chronic stroke subjects: Task training system for stroke rehabilitation , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[30]  K. Stubblefield,et al.  Hand Rehabilitation Following Stroke: A Pilot Study of Assisted Finger Extension Training in a Virtual Environment , 2007, Topics in stroke rehabilitation.

[31]  H. Stam,et al.  Mirror therapy improves hand function in subacute stroke: a randomized controlled trial. , 2008, Archives of physical medicine and rehabilitation.

[32]  Alex Mihailidis,et al.  Development of a robotic device for upper limb stroke rehabilitation: A user-centered design approach , 2011, Paladyn J. Behav. Robotics.

[33]  Weihai Chen,et al.  A haptic device wearable on a human arm , 2004, IEEE Conference on Robotics, Automation and Mechatronics, 2004..

[34]  Alberto Borboni,et al.  Neural manual vs. robotic assisted mobilization to improve motion and reduce pain hypersensitivity in hand osteoarthritis: study protocol for a randomized controlled trial , 2017, Journal of physical therapy science.

[35]  Christophe Duret,et al.  Evolution of upper limb kinematics four years after subacute robot-assisted rehabilitation in stroke patients , 2018, The International journal of neuroscience.

[36]  H. Krebs,et al.  Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review , 2008, Neurorehabilitation and neural repair.

[37]  Mario Cortese,et al.  Usability test of a hand exoskeleton for activities of daily living: an example of user-centered design , 2017, Disability and rehabilitation. Assistive technology.

[38]  R. Vaidyanathan,et al.  Development of a parametric kinematic model of the human hand and a novel robotic exoskeleton , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[39]  J. B. Brooke,et al.  SUS: A 'Quick and Dirty' Usability Scale , 1996 .

[40]  Yoky Matsuoka,et al.  Comparison of control strategies for an EMG controlled orthotic exoskeleton for the hand , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[41]  Jean-Lon Chen,et al.  An Evaluation of the Design and Usability of a Novel Robotic Bilateral Arm Rehabilitation Device for Patients with Stroke , 2017, Front. Neurorobot..

[42]  Rahsaan J. Holley,et al.  Robotic Approaches for Rehabilitation of Hand Function After Stroke , 2012, American journal of physical medicine & rehabilitation.

[43]  Yasuhisa Hasegawa,et al.  Five-fingered assistive hand with mechanical compliance of human finger , 2008, 2008 IEEE International Conference on Robotics and Automation.

[44]  G. Giralt,et al.  Safe and dependable physical human-robot interaction in anthropic domains: State of the art and challenges , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[45]  Rahsaan J. Holley,et al.  Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[46]  M. Fornage,et al.  Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association , 2017, Circulation.

[47]  D. Cicchetti Guidelines, Criteria, and Rules of Thumb for Evaluating Normed and Standardized Assessment Instruments in Psychology. , 1994 .

[48]  John A. Main,et al.  An anthropomorphic hand exoskeleton to prevent astronaut hand fatigue during extravehicular activities , 1997, IEEE Trans. Syst. Man Cybern. Part A.

[49]  Marco Troncossi,et al.  An Original Classification of Rehabilitation Hand Exoskeletons , 2016 .

[50]  C. Orizio,et al.  Changes in skeletal muscle perfusion and spasticity in patients with poststroke hemiparesis treated by robotic assistance (Gloreha) of the hand , 2016, Journal of physical therapy science.

[51]  Peter M. Rothwell,et al.  Risk Of Selection Bias And Misrepresentation Of Stroke Populations With Dichotomous Analyses Of The Modified Rankin Scale In Stroke Trials , 2017 .

[52]  Ching-yi Wu,et al.  A randomized controlled trial of modified constraint-induced movement therapy for elderly stroke survivors: changes in motor impairment, daily functioning, and quality of life. , 2007, Archives of physical medicine and rehabilitation.

[53]  Jen-Yuan Chang,et al.  Modeling and development of tension force measurement system for cable-driven hand exoskeleton robot , 2015, 2015 IEEE International Conference on Advanced Intelligent Mechatronics (AIM).

[54]  Antonio Cerasa,et al.  Exoskeleton-Robot Assisted Therapy in Stroke Patients: A Lesion Mapping Study , 2018, Front. Neuroinform..

[55]  Soo-Jin Lee,et al.  Current hand exoskeleton technologies for rehabilitation and assistive engineering , 2012 .