Effect of eluent composition and pH and chemiluminescent reagent pH on ion chromatographic selectivity and luminol-based chemiluminescence detection of Co(2+), Mn(2+) and Fe(2+) at trace levels.

The alkaline-luminol/H(2)O(2)-based chemiluminescent (CL) detection of Fe(2+), Co(2+), and Mn(2+), separated with a Dionex CS5A ion chromatographic phase was studied by means of a multi-pump flow system allowing the variation of the post-column solution composition. A perchlorate gradient at pH 1.9 (with HCl) was used to separate cations partially complexed with 5.6mM oxalate present in the eluent and necessary for the chosen separation phase. A 0.91mM luminol, 3.3mM H(2)O(2) in 0.25M carbonate buffer at pH 10.5 composition was chosen as CL reagent solution. The chosen pH value warrants signal repeatability and wider linearity range although absolute signal is not maximum. The CL signal was related to the pH of the two post-column mixing solutions. Calibration plots of Co(2+) and Fe(2+) were linear in the chosen concentration range whilst a parabolic model was the best fit for Mn(2+). Detection limits were 0.24, 0.50 and 375nM for Co(2+), Fe(2+) and Mn(2+), respectively. The method was used to determine Co(2+) at trace level in commercial copper chelates used for animal feeding. A comparison with a chromatographic method with spectrophotometric detection was made giving results comparable both in absolute values and accuracy.

[1]  W. Seitz,et al.  Mechanism of cobalt catalysis of luminol chemiluminescence , 1975 .

[2]  Andre. Hubaux,et al.  Decision and detection limits for calibration curves , 1970 .

[3]  Ruma Banerjee,et al.  The many faces of vitamin B12: catalysis by cobalamin-dependent enzymes. , 2003, Annual review of biochemistry.

[4]  E. Miyamoto,et al.  TLC SEPARATION AND ANALYSIS OF VITAMIN B12 AND RELATED COMPOUNDS IN FOOD , 2002 .

[5]  M. C. Bruzzoniti,et al.  A study of the mechanisms involved in the separation of metal ions with a mixed-bed stationary phase , 2002 .

[6]  J. Tison,et al.  Development of a sampling and flow injection analysis technique for iron determination in the sea ice environment , 2006 .

[7]  A. Tapparo,et al.  Complex formation between aluminium(III) and two hydroxy-aromatic ligands : 2-hydroxyphenylethanone and 2-hydroxybenzeneacetic acid , 1999 .

[8]  P. Worsfold,et al.  Determination of cobalt and iron in estuarine and coastal waters using flow injection with chemiluminescence detection , 2000 .

[9]  J. Aubry Search for singlet oxygen in the decomposition of hydrogen peroxide by mineral compounds in aqueous solutions , 1985 .

[10]  Z. Berner,et al.  The Application of Microelectrodes for the Measurements of Trace Metals in Water , 2005 .

[11]  A. Townshend,et al.  Determination of zinc and cadmium by flow injection analysis and chemiluminescence , 1981 .

[12]  M. Rashid,et al.  Determination of heavy metals in air particulate matter by ion chromatography , 1996 .

[13]  Manabu Yamamoto,et al.  Determination of ultra-trace levels of cobalt by ion chromatographic separation and chemiluminescence detection , 1989 .

[14]  Phil Jones,et al.  Determination of cobalt at picogram levels by high-performance liquid chromatography with chemiluminescence detection , 1989 .

[15]  W. Seitz,et al.  Determination of trace amounts of iron(II) using chemiluminescence analysis , 1972 .

[16]  A. Alwarthan,et al.  Chemiluminescence determination of iron(II) and titanium(III) by flow injection analysis based on reactions with and without luminol , 1987 .

[17]  Jicun Ren,et al.  Chemiluminescence detection for capillary electrophoresis and microchip capillary electrophoresis , 2006 .

[18]  A. Townshend,et al.  Determination of manganese(II) by a chemiluminescence reaction. , 1981, Talanta.

[19]  Chengxiao Zhang Determination of copper ions in waters by electrochemical stripping chemiluminescence analysis in situ , 1998 .

[20]  P. Sedwick,et al.  Real-time monitoring of picomolar concentrations of iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation. , 2002, Environmental science & technology.

[21]  J. Kankare,et al.  Application of the electrochemiluminescence of luminol to the determination of copper , 1980 .

[22]  T. Nieman,et al.  Effect of iron(II), cobalt(II), copper(II), and manganese(II) on the chemiluminescence of luminol in the absence of hydrogen peroxide , 1983 .