Real‐time hybrid testing of a smart base isolation system

SUMMARY Real-time hybrid testing is a very effective technique for evaluating the dynamic responses of rate-dependent structural systems subjected to earthquake excitation. A smart base isolation system has been proposed by others using conventional low-damping isolators and controllable damping devices such as magnetorheological (MR) dampers to achieve specified control target performance. In this paper, real-time hybrid tests of a smart base isolation system are conducted. The simulation is for a base-isolated two-degrees-of-freedom building model where the superstructure and the low-damping base isolator are numerically simulated, and the MR damper is physically tested. The target displacement obtained from the step-by-step integration of the numerical substructure is imposed on the MR damper, which is driven by three different control algorithms in real-time. To compensate the actuator delay and improve the accuracy of the test, an adaptive phase-lead compensator is implemented. The accuracy of each test is investigated by using the root mean square error and the tracking indicator. Experimental results demonstrate that the hybrid testing procedure using the proposed actuator compensation techniques is effective for investigating the control performance of the MR damper in a smart base isolation system. Copyright © 2013 John Wiley & Sons, Ltd.

[1]  Satish Nagarajaiah,et al.  Seismic control of smart base isolated buildings with new semiactive variable damper , 2007 .

[2]  Andrei M. Reinhorn,et al.  Control of Sliding-Isolated Buildings Using Sliding-Mode Control , 1996 .

[3]  Erik A. Johnson,et al.  "SMART" BASE ISOLATION SYSTEMS , 2000 .

[4]  Y. Namita,et al.  Real‐time hybrid experimental system with actuator delay compensation and its application to a piping system with energy absorber , 1999 .

[5]  P. Benson Shing,et al.  Performance of a real‐time pseudodynamic test system considering nonlinear structural response , 2007 .

[6]  Mohamed Abdel-Rohman,et al.  Optimal Control of Civil Engineering Structures , 1980 .

[7]  Y. Wen Method for Random Vibration of Hysteretic Systems , 1976 .

[8]  Masayoshi Nakashima,et al.  Development, potential, and limitations of real–time online (pseudo–dynamic) testing , 2001, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[9]  M. V. Sivaselvan,et al.  Dynamic force control with hydraulic actuators using added compliance and displacement compensation , 2008 .

[10]  Chin-Hsiung Loh,et al.  Semiactive Control of Building Structures with Semiactive Tuned Mass Damper , 2005 .

[11]  Jian Zhao,et al.  Considerations for the development of real-time dynamic testing using servo-hydraulic actuation , 2003 .

[12]  Marvin W. Halling,et al.  Near-Source Ground Motion and its Effects on Flexible Buildings , 1995 .

[13]  Keh-Chyuan Tsai,et al.  Dual compensation strategy for real‐time hybrid testing , 2013 .

[14]  Brian M. Phillips Model-based feedforward-feedback control for real-time hybrid simulation of large-scale structures , 2012 .

[15]  Guang Li,et al.  Testing of dynamically substructured, base-isolated systems using adaptive control techniques , 2009 .

[16]  Andrei M. Reinhorn,et al.  Development of a Controller Platform for Force-Based Real-Time Hybrid Simulation , 2012 .

[17]  Michael D. Symans,et al.  Fuzzy logic control of bridge structures using intelligent semi‐active seismic isolation systems , 1999 .

[18]  Stephen A. Mahin,et al.  Pseudodynamic Method for Seismic Testing , 1985 .

[19]  Andrew W. Smyth,et al.  On-Line Identification of Hysteretic Systems , 1998 .

[20]  Richard Christenson,et al.  Large-Scale Experimental Verification of Semiactive Control through Real-Time Hybrid Simulation , 2008 .

[21]  Shirley J. Dyke,et al.  Role of Control-Structure Interaction in Protective System Design , 1995 .

[22]  James M. Ricles,et al.  Stability and accuracy analysis of outer loop dynamics in real‐time pseudodynamic testing of SDOF systems , 2007 .

[23]  Masayoshi Nakashima,et al.  Real-time on-line test for MDOF systems , 1999 .

[24]  Andrei M. Reinhorn,et al.  Real-Time Hybrid Simulation Using Shake Tables and Dynamic Actuators , 2011 .

[25]  James M. Ricles,et al.  Tracking Error-Based Servohydraulic Actuator Adaptive Compensation for Real-Time Hybrid Simulation , 2010 .

[26]  Andrei M. Reinhorn,et al.  Compensation of actuator delay and dynamics for real‐time hybrid structural simulation , 2008 .

[27]  Hyung-Jo Jung,et al.  Real-time hybrid testing of a steel-structure equipped with large-scale magneto-rheological dampers applying semi-active control algorithms , 2008 .

[28]  Martin S. Williams,et al.  Stability and Delay Compensation for Real-Time Substructure Testing , 2002 .

[29]  Shirley J. Dyke,et al.  Benchmark Control Problems for Seismically Excited Nonlinear Buildings , 2004 .