Needle-tissue interaction forces--a survey of experimental data.

The development of needles, needle-insertion simulators, and needle-wielding robots for use in a clinical environment depends on a thorough understanding of the mechanics of needle-tissue interaction. It stands to reason that the forces arising from this interaction are influenced by numerous factors, such as needle type, insertion speed, and tissue characteristics. However, exactly how these factors influence the force is not clear. For this reason, the influence of various factors on needle insertion-force was investigated by searching literature for experimental data. This resulted in a comprehensive overview of experimental insertion-force data available in the literature, grouped by factor for quick reference. In total, 99 papers presenting such force data were found, with typical peak forces in the order of 1-10N. The data suggest, for example, that higher velocity tends to decrease puncture force and increase friction. Furthermore, increased needle diameter was found to increase peak forces, and conical needles were found to create higher peak forces than beveled needles. However, many questions remain open for investigation, especially those concerning the influence of tissue characteristics.

[1]  P. Dupont,et al.  Trajectory Optimization for Dynamic Needle Insertion , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[2]  Tarun Kanti Podder,et al.  Needle Insertion Force Estimation Model using Procedure-specific and Patient-specific Criteria , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Masakatsu G. Fujie,et al.  A robotic palpation-based needle insertion method for diagnostic biopsy and treatment of breast cancer , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[4]  Maud Marchal,et al.  Modeling of Needle-Tissue Interaction Using Ultrasound-Based Motion Estimation , 2007, MICCAI.

[5]  Miguel Srougi,et al.  Safety profile of trocar and insufflation needle access systems in laparoscopic surgery. , 2009, Journal of the American College of Surgeons.

[6]  P. Stergiopoulos,et al.  A framework for the haptic rendering of the human hand , 2003, 11th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, 2003. HAPTICS 2003. Proceedings..

[7]  T. Togawa,et al.  Detection of needle puncture to blood vessel using puncture force measurement , 2005, Medical and Biological Engineering and Computing.

[8]  Oliver A. Shergold,et al.  Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin. , 2005, Journal of biomechanical engineering.

[9]  F Tendick,et al.  Measuring in vivo animal soft tissue properties for haptic modeling in surgical simulation. , 2001, Studies in health technology and informatics.

[10]  Gregory S. Chirikjian,et al.  Robotic Needle Steering: Design, Modeling, Planning, and Image Guidance , 2011 .

[11]  T. A. Thomas,et al.  Simulation of resistance forces acting on surgical needles , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  M. Moallem,et al.  Trajectory generation for robotic needle insertion in soft tissue , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  R. Zahiri-Azar,et al.  Parameter Identification for a Needle-Tissue Interaction Model , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Ryutaro Himeno,et al.  Simulations of Needle Insertion by Using a Eulerian Hydrocode FEM and the Experimental Validations , 2008, MICCAI.

[15]  P. D. Warriss,et al.  Meat Science: An Introductory Text , 2010 .

[16]  Septimiu E. Salcudean,et al.  Needle insertion modeling and simulation , 2003, IEEE Trans. Robotics Autom..

[17]  Vincent Hayward,et al.  Estimation of the Fracture Toughness of Soft Tissue from Needle Insertion , 2008, ISBMS.

[18]  Septimiu E. Salcudean,et al.  Needle insertion modelling and simulation , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[19]  Allison M. Okamura,et al.  Robotic needle insertion: effects of friction and needle geometry , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[20]  Mehrdad Moallem,et al.  Control of soft tissue deformation during robotic needle insertion , 2006, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[21]  Peter N. Brett,et al.  Schemes for the identification of tissue types and boundaries at the tool point for surgical needles , 2000, IEEE Transactions on Information Technology in Biomedicine.

[22]  Masakatsu G. Fujie,et al.  Development and validation of a viscoelastic and nonlinear liver model for needle insertion , 2008, International Journal of Computer Assisted Radiology and Surgery.

[23]  Holton Ll,et al.  Force models for needle insertion created from measured needle puncture data. , 2001 .

[24]  Ichiro Sakuma,et al.  Analysis of Forces during Robotic Needle Insertion to Human Vertebra , 2003, MICCAI.

[25]  Jaydev P. Desai,et al.  A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction , 2007, Medical Image Anal..

[26]  Septimiu E. Salcudean,et al.  Simulated interactive needle insertion , 2002, Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002.

[27]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[28]  Zeike A. Taylor,et al.  Subject-specific non-linear biomechanical model of needle insertion into brain , 2008 .

[29]  Kyle B. Reed,et al.  Mechanics of Flexible Needles Robotically Steered through Soft Tissue , 2010, Int. J. Robotics Res..

[30]  T. Podder,et al.  A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention. , 2009, Medical physics.

[31]  L. J. Teunissen,et al.  Clinical Results with the Acoustic Puncture Assist Device, a New Acoustic Device to Identify the Epidural Space , 2003, Anesthesia and analgesia.

[32]  Ehsan Dehghan,et al.  Needle Insertion Study Using Ultrasound-Based 2D Motion Tracking , 2008, MICCAI.

[33]  D Stredney,et al.  Development of the force-feedback model for an epidural needle insertion simulator. , 1998, Studies in health technology and informatics.

[34]  Imran Fazal,et al.  Needle insertion forces for haptic feedback device , 2009, 2009 IEEE Symposium on Industrial Electronics & Applications.

[35]  Septimiu E. Salcudean,et al.  Interactive simulation of needle insertion models , 2005, IEEE Transactions on Biomedical Engineering.

[36]  Ann H. Kim,et al.  Blunt atrial transseptal puncture using excimer laser in swine , 2007, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[37]  K. T. Ramesh,et al.  Observations of needle-tissue interactions , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  Yongde Zhang,et al.  Evaluation of robotic needle insertion in conjunction with in vivo manual insertion in the operating room , 2005, ROMAN 2005. IEEE International Workshop on Robot and Human Interactive Communication, 2005..

[39]  Masahiro Kanazawa,et al.  Differences in penetration force of intravenous catheters: effect of grinding methods on inner needles of intravenous catheters. , 2004, The Tokai journal of experimental and clinical medicine.

[40]  K. Naemura Comparative Phantom Study on Epidural Anesthesia Needle , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[41]  V. Knappertz,et al.  Needles: a comparison study. , 2009, Medical device technology.

[42]  Mehrdad R. Kermani,et al.  A compact dynamic force model for needle-tissue interaction , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[43]  T. Lechner,et al.  Thoracic epidural puncture guided by an acoustic signal: clinical results , 2004, European journal of anaesthesiology.

[44]  Rajnikant V. Patel,et al.  Deflection of a Flexible Needle during Insertion into Soft Tissue , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[45]  Nabil Zemiti,et al.  Design of an ultrasound-guided robotic brachytherapy needle-insertion system , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[46]  Stephen H. D. Jackson INT CONGR SER , 2001 .

[47]  James R. Fox,et al.  Biomechanical response to acupuncture needling in humans. , 2001, Journal of applied physiology.

[48]  T. Togawa,et al.  Detection of puncturing vessel wall for automatic blood sampling , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[49]  A. Cuschieri,et al.  Development of a shape memory alloy multiple-point injector for chemotherapy , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[50]  Sarthak Misra,et al.  Mechanics of needle-tissue interaction , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[51]  W. Jensen,et al.  In vivo implant mechanics of single-shaft microelectrodes in peripheral nervous tissue , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[52]  Brian L. Davies,et al.  A robotic system for blood sampling , 2000, IEEE Transactions on Information Technology in Biomedicine.

[53]  Pierre E. Dupont,et al.  Mechanics of Dynamic Needle Insertion into a Biological Material , 2010, IEEE Transactions on Biomedical Engineering.

[54]  Derek A Gould,et al.  In vivo force during arterial interventional radiology needle puncture procedures. , 2005, Studies in health technology and informatics.

[55]  T. Podder,et al.  In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy. , 2006, Medical physics.

[56]  Tarun Kanti Podder,et al.  In-vivo Measurement of Surgical Needle Intervention Parameters: A Pilot Study , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[57]  Luc Soler,et al.  IN VIVO STUDY OF FORCES DURING NEEDLE INSERTIONS , 2004 .

[58]  Pierre E. Dupont,et al.  Fast needle insertion to minimize tissue deformation and damage , 2009, 2009 IEEE International Conference on Robotics and Automation.

[59]  Yu Xie,et al.  A force control based cell injection approach in a bio-robotics system , 2009, 2009 IEEE International Conference on Robotics and Automation.

[60]  Masakatsu G. Fujie,et al.  Development of a novel approach, “palpation based needle insertion,” for breast cancer treatment , 2009, 2008 IEEE International Conference on Robotics and Biomimetics.

[61]  Ana Luisa Trejos,et al.  Force sensing and its application in minimally invasive surgery and therapy: A survey , 2010 .

[62]  K Yan,et al.  A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention. , 2009, Medical physics.

[63]  J. Webster,et al.  Mechanical compliance of the endocardium. , 2002, Journal of biomechanics.

[64]  J J W Lagendijk,et al.  Development of a tapping device: a new needle insertion method for prostate brachytherapy , 2006, Physics in medicine and biology.

[65]  B R Thomadsen,et al.  Observations on rotating needle insertions using a brachytherapy robot , 2007, Physics in medicine and biology.

[66]  T. Togawa,et al.  Development of an automatic blood sampling system: control of the puncturing needle by measuring forces , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[67]  Christina Simone,et al.  MODELING OF NEEDLE INSERTION FORCES FOR PERCUTANEOUS THERAPIES , 2002 .

[68]  Jaydev P. Desai,et al.  Reality-based needle insertion simulation for haptic feedback in prostate brachytherapy , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[69]  K. T. Ramesh,et al.  Needle-tissue interaction forces for bevel-tip steerable needles , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[70]  W R Walsh,et al.  Resistance forces acting on suture needles. , 2001, Journal of biomechanics.

[71]  T. Vu-khanh,et al.  Puncture of elastomer membranes by medical needles. Part II: Mechanics , 2009 .

[72]  Kyle B. Reed,et al.  Controlling a robotically steered needle in the presence of torsional friction , 2009, 2009 IEEE International Conference on Robotics and Automation.

[73]  Masakatsu G. Fujie,et al.  Development of an integrated needle insertion system with image guidance and deformation simulation , 2010, Comput. Medical Imaging Graph..

[74]  B. T. Sitzman,et al.  Comparison of the force required for dural puncture with different spinal needles and subsequent leakage of cerebrospinal fluid. , 1994, Anesthesia and analgesia.

[75]  Allison M. Okamura,et al.  Modeling of needle insertion forces for robot-assisted percutaneous therapy , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[76]  B. Hannaford,et al.  Surgical robotics : systems, applications and visions , 2011 .

[77]  Masakatsu G. Fujie,et al.  Modeling of conditions where a puncture occurs during needle insertion considering probability distribution , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[78]  G. Gillies,et al.  Measurement of the force required to move a neurosurgical probe through in vivo human brain tissue , 1999, IEEE Transactions on Biomedical Engineering.

[79]  Z T H Tse,et al.  A haptic unit designed for magnetic-resonance-guided biopsy , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[80]  Masakatsu G. Fujie,et al.  Developing a planning method for straight needle insertion using probability-based condition where a puncture occurs , 2009, 2009 IEEE International Conference on Robotics and Automation.

[81]  Allison M. Okamura,et al.  Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review , 2008, PRESENCE: Teleoperators and Virtual Environments.

[82]  Rajnikant V. Patel,et al.  A distributed model for needle-tissue friction in percutaneous interventions , 2011, 2011 IEEE International Conference on Robotics and Automation.

[83]  Jaydev P. Desai,et al.  Towards a teleoperated needle driver robot with haptic feedback for RFA of breast tumors under continuous MRI , 2009, Medical Image Anal..

[84]  Dan Stoianovici,et al.  Does needle rotation improve lesion targeting? , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.

[85]  K. Naemura,et al.  Effect of the Needle Tip Height on the Puncture Force in a Simplified Epidural Anesthesia Simulator , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[86]  Allison M. Okamura,et al.  A Velocity-Dependent Model for Needle Insertion in Soft Tissue , 2005, MICCAI.

[87]  Allison M. Okamura,et al.  Measurement of the Tip and Friction Force Acting on a Needle during Penetration , 2002, MICCAI.

[88]  L. Barbe,et al.  Online Robust Model Estimation and Haptic Clues Detection during In Vivo Needle Insertions , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[89]  Blake Hannaford,et al.  The Biomechanics of Percutaneous Needle Insertion , 2008, MMVR.

[90]  R. Lawrie,et al.  Lawrie's Meat Science , 2006 .

[91]  Chengwei Wu,et al.  Measurement and Prediction of Insertion Force for the Mosquito Fascicle Penetrating into Human Skin , 2009 .

[92]  A.P.S. Selvadurai,et al.  Deflections of a rubber membrane , 2006 .

[93]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[94]  Rajni V. Patel,et al.  Minimization of needle deflection in robot‐assisted percutaneous therapy , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[95]  Robert Rohling,et al.  Instrumentation of the Loss-of-Resistance Technique for Epidural Needle Insertion , 2009, IEEE Transactions on Biomedical Engineering.

[96]  D. Gossot,et al.  Development of an ultrasonically activated trocar system , 2001, Surgical Endoscopy And Other Interventional Techniques.

[97]  Franck Vidal,et al.  Simulation of ultrasound guided needle puncture using patient specific data with 3D textures and volume haptics , 2008 .

[98]  Masakatsu G. Fujie,et al.  Modeling of friction force based on relative velocity between liver tissue and needle for needle insertion simulation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[99]  Rajnikant V. Patel,et al.  Experimental study of robotic needle insertion in soft tissue , 2004, CARS.

[100]  G. Auer,et al.  A new semi-automated instrument to improve the fine needle aspiration procedure during breast lesion cell sampling. , 2009, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[101]  M. C. Lewis,et al.  How much work is required to puncture dura with Tuohy needles? , 2000, British journal of anaesthesia.