Mathematical model and minimal measurement system for optimal control of heated humidifiers in neonatal ventilation.

The control of thermo-hygrometric conditions of gas delivered in neonatal mechanical ventilation appears to be a particularly difficult task, mainly due to the vast number of parameters to be monitored and the control strategies of heated humidifiers to be adopted. In the present paper, we describe the heat and fluid exchange occurring in a heated humidifier in mathematical terms; we analyze the sensitivity of the relative humidity of outlet gas as a function of thermo-hygrometric and fluid-dynamic parameters of delivered gas; we propose a control strategy that will enable the stability of outlet gas thermo-hygrometric conditions. The mathematical model is represented by a hyper-surface containing the functional relations between the input variables, which must be measured, and the output variables, which have to remain constant. Model sensitivity analysis shows that heated humidifier efficacy and stability of outlet gas thermo-hygrometric conditions are principally influenced by four parameters: liquid surface temperature, gas flow rate, inlet gas temperature and inlet gas relative humidity. The theoretical model has been experimentally validated in typical working conditions of neonatal applications. The control strategy has been implemented by a minimal measurement system composed of three thermometers, a humidity sensor, and a flow rate sensor, and based on the theoretical model. Outlet relative humidity, contained in the range 90+/-4% and 94+/-4%, corresponding with temperature variations in the range 28+/-2 degrees C and 38+/-2 degrees C respectively, has been obtained in the whole flow rate range typical of neonatal ventilation from 1 to 10 L/min. We conclude that in order to obtain the stability of the thermo-hygrometric conditions of the delivered gas mixture: (a) a control strategy with a more complex measurement system must be implemented (i.e. providing more input variables); (b) and the gas may also need to be pre-warmed before entering the humidifying chamber.

[1]  H. Schiffmann Humidification of respired gases in neonates and infants. , 2006, Respiratory care clinics of North America.

[2]  W. Tarnow-Mordi,et al.  Is neonatal inspired gas humidity accurately controlled by humidifier temperature? , 1991, Critical care medicine.

[3]  Nigel Rankin,et al.  Energy balance in the intubated human airway is an indicator of optimal gas conditioning , 2002, Critical care medicine.

[4]  Sergio Silvestri,et al.  A transistor based air flow transducer for thermohygrometric control of neonatal ventilatory applications. , 2008, The Review of scientific instruments.

[5]  J. Brock‐Utne,et al.  Paediatric anaesthetic breathing systems , 1996, Paediatric anaesthesia.

[6]  P. Pelosi,et al.  Performance of heated wire humidifiers: an in vitro study. , 2007, Journal of critical care.

[7]  T Mashimo,et al.  Performance of heated humidifiers with a heated wire according to ventilatory settings. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[8]  G. Smaldone,et al.  Y-piece temperature and humidification during mechanical ventilation. , 2009, Respiratory care.

[9]  Mark Hochmann,et al.  The effect of inlet gas temperatures on heated humidifier performance. , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[10]  J. Roustan,et al.  Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation , 2005, Intensive Care Medicine.

[11]  K. Miyasaka,et al.  Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire , 1992, Critical care medicine.

[12]  D. Dreyfuss,et al.  Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. , 1999, Chest.

[13]  François Lellouche,et al.  Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. , 2004, American journal of respiratory and critical care medicine.

[14]  R. Branson Conditioning inspired gases:the search for relevant physiologic end points. , 2009, Respiratory care.

[15]  Y. Jammes,et al.  Airway humidification with a heat and moisture exchanger in mechanically ventilated neonates , 2007, Intensive Care Medicine.