Quantitative analysis of image truncation in focal-beam CT

The authors measured truncation artifacts using a phantom model of the human thorax. Reconstructions were performed with both iterative cone-beam transmission maximum likelihood (TRML) and cone-beam filtered backprojection (CB-FBP). When CB-FBP was used, image truncation created 'streak' artifacts of increased density, distorted the elliptical phantom body contour into a circle with reduced radius, and increased the apparent density of the lungs. SPECT attenuation compensation using this truncated CB-FBP map produced line-source activities that were only 65% of the correct 'in-air' values. Thus, CB-FBP attenuation maps will generally be unacceptable for clinical SPECT attenuation compensation. The truncation-streak artifacts were eliminated with TRML, but in some regions the body contour was not sharply defined, and the reconstructed density was low in the lungs and nonzero outside the body contour. An elliptical support prior eliminated the 'in-air' density and improved the accuracy in the lungs, as determined by narrow-beam transmission measurements with a germanium detector. For iterations above twenty-four, TRML images were noisier than CB-FBP images with a Hann filter, and at least thirty iterations were required for accurate reconstruction. SPECT line-source attenuation compensation with a truncated TRML map was accurate to within 20%, depending upon the slice number and the source location.

[1]  S. Manglos,et al.  Attenuation maps for SPECT determined using cone beam transmission computed tomography , 1990 .

[2]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[3]  G T Herman,et al.  Evaluation of a preprocessing algorithm for truncated CT projections. , 1981, Journal of computer assisted tomography.

[4]  C E Floyd,et al.  Tc-99m attenuation coefficients in water-filled phantoms determined with gamma cameras. , 1984, Medical physics.

[5]  J Llacer,et al.  Feasible images and practical stopping rules for iterative algorithms in emission tomography. , 1989, IEEE transactions on medical imaging.

[6]  H. Murayama,et al.  Convolutional image reconstruction for quantitative single photon emission computed tomography , 1984 .

[7]  F D Thomas,et al.  Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  The effect of non-uniform attenuation compensation on myocardial SPECT defect analysis , 1993 .

[9]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  J R Galt,et al.  SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Ronald J. Jaszczak,et al.  Transmission Computed Tomography Data Acquisition with a SPECT System , 1987 .

[12]  R J Jaszczak,et al.  Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras , 1979, Physics in medicine and biology.

[13]  A. Haaga,et al.  Computed tomography of the whole body , 1988 .

[14]  G.L. Zeng,et al.  Non-uniform attenuation correction using simultaneous transmission and emission converging tomography , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[15]  F D Thomas,et al.  Cone-beam transmission computed tomography for nonuniform attenuation compensation of SPECT images. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Ronald J. Jaszczak,et al.  Weighted backprojection implemented with a non-uniform attenuation map for improved SPECT quantitation , 1988 .

[17]  C E Floyd,et al.  Maximum likelihood reconstruction for cone beam SPECT: development and initial tests. , 1989, Physics in medicine and biology.

[18]  G T Gullberg,et al.  SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[20]  Stephen M. Moore,et al.  An Evaluation of the Use of Sieves for Producing Estimates. Of Radioactivity Distributions with the EM Algorithm for PET , 1986, IEEE Transactions on Nuclear Science.

[21]  Lee-Tzuu Chang,et al.  Attenuation Correction and Incomplete Projection in Single Photon Emission Computed Tomography , 1979, IEEE Transactions on Nuclear Science.

[22]  B.M.W. Tsui,et al.  Attenuation and detector response compensations used with Gibbs prior distributions for maximum a posteriori SPECT reconstruction , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[23]  Gengsheng L. Zeng,et al.  A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative EM algorithms , 1990 .

[24]  E L Ritman,et al.  Emission-computed tomography and its application to imaging of acute myocardial infarction in intact dogs using Tc-99m pyrophosphate. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  S H Manglos,et al.  Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects. , 1992, Physics in medicine and biology.

[26]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[27]  Koichi Ogawa,et al.  A Reconstruction Algorithm from Truncated Projections , 1984, IEEE Transactions on Medical Imaging.