A polypyrrole-based solid-contact Pb2+-selective PVC-membrane electrode with a nanomolar detection limit
暂无分享,去创建一个
Ernö Pretsch | E. Pretsch | R. E. Gyurcsányi | E. Lindner | Ernö Lindner | Jolanda Sutter | Robert E Gyurcsányi | J. Sutter
[1] P. Bühlmann,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.
[2] E. Pretsch,et al. Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane Electrodes , 1997 .
[3] Ernö Pretsch,et al. Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit. , 2002, Analytical chemistry.
[4] E. Bakker,et al. Effect of Transmembrane Electrolyte Diffusion on the Detection Limit of Carrier-Based Potentiometric Ion Sensors , 1998 .
[5] J. Bobacka,et al. Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. , 1999, Analytical chemistry.
[6] B. Hattendorf,et al. Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS. , 2001, Analytical chemistry.
[7] W. E. Morf,et al. Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes , 2002 .
[8] R. Cattrall,et al. Some alkylphosphoric acid esters for use in coated-wire calcium-selective electrodes: Part I. Response characteristics , 1975 .
[9] Ernö Pretsch,et al. Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes , 1999 .
[10] E. Hall,et al. Ion-transport and diffusion coefficients of non-plasticised methacrylic-acrylic ion-selective membranes. , 2004, Talanta.
[11] A. Ivaska,et al. Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin , 1999 .
[12] P. Hauser,et al. Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes. , 1998, Analytical chemistry.
[13] E. Hall,et al. An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range. , 2004, Analytical chemistry.
[14] R. E. Gyurcsányi,et al. Microfabricated ISEs: critical comparison of inherently conducting polymer and hydrogel based inner contacts. , 2004, Talanta.
[15] A. Ivaska,et al. All-Solid-State Chloride Sensors with Poly(3-Octylthiopene) Matrix and Trihexadecylmethylammonium Chlorides as an Ion Exchanger Salt , 2004 .
[16] Hakhyun Nam,et al. All-solid-state carbonate-selective electrode based on a molecular tweezer-type neutral carrier with solvent-soluble conducting polymer solid contact. , 2002, Talanta.
[17] Ernö Pretsch,et al. Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution , 1999 .
[18] A. Michalska,et al. Conducting polymer membranes for low activity potentiometric ion sensing. , 2004, Talanta.
[19] R. E. Gyurcsányi,et al. Tailored transport through ion-selective membranes for improved detection limits and selectivity coefficients , 1999 .
[20] K. Maksymiuk,et al. Studies on Spontaneous Charging/Discharging Processes of Polypyrrole in Aqueous Electrolyte Solutions , 2001 .
[21] A. Michalska,et al. All solid-state hydrogen ion-selective electrode based on a conducting poly(pyrrole) solid contact , 1994 .
[22] Ernö Pretsch,et al. Redox-Active Self-Assembled Monolayers for Solid-Contact Polymeric Membrane Ion-Selective Electrodes , 2002 .
[23] E. Bakker. Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective Electrodes , 1997 .
[24] Johan Bobacka,et al. Single-piece all-solid-state ion-selective electrode , 1995 .
[25] T. Osaka,et al. Analysis of the long-term potential stability of an all-solid-state potassium-selective electrode with electroactive polypyrrole film , 1996 .
[26] P. Bühlmann,et al. Selectivity of potentiometric ion sensors. , 2000, Analytical chemistry.
[27] A. Ivaska,et al. Influence of oxygen and carbon dioxide on the electrochemical stability of poly(3,4-ethylenedioxythiophene) used as ion-to-electron transducer in all-solid-state ion-selective electrodes , 2002 .
[28] A. Michalska,et al. All-Solid-State Potentiometric Sensors for Potassium and Sodium Based on Poly(pyrrole) Solid Contact , 1997 .
[29] Richard B. Brown,et al. Enhancing EMF stability of solid-state ion-selective sensors by incorporating lipophilic silver-ligand complexes within polymeric films , 1996 .
[30] N. D. de Rooij,et al. Potential Drifts of Solid‐Contacted Ion‐Selective Electrodes Due to Zero‐Current Ion Fluxes Through the Sensor Membrane , 2000 .
[31] A. Michalska,et al. Lowering the Detection Limit of Ion-Selective Plastic Membrane Electrodes with Conducting Polymer Solid Contact and Conducting Polymer Potentiometric Sensors , 2003 .
[32] A. Hulanicki,et al. Calcium-selective electrodes with pvc membranes and solid internal contacts , 1976 .
[33] Dermot Diamond,et al. All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact , 1992 .
[34] P. Hauser,et al. A potassium-ion selective electrode with valinomycin based poly(vinyl chloride) membrane and a poly(vinyl ferrocene) solid contact , 1995 .
[35] Ernö Pretsch,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.
[36] R. E. Gyurcsányi,et al. Picomolar detection limits with current-polarized Pb2+ ion-selective membranes. , 2001, Analytical chemistry.
[37] Ernö Pretsch,et al. Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range , 2004 .