A polypyrrole-based solid-contact Pb2+-selective PVC-membrane electrode with a nanomolar detection limit

Ion-selective electrodes (ISE) based on conventional plasticized PVC membranes with solid inner contact (SC) have so far had unsatisfactory lower detection limits. Here it is shown that electropolymerization of pyrrole in the presence of potassium hexacyanoferrate(II)/(III) on Pt results in adequate inner contact for SC-ISE. The nanomolar lower detection limit achieved with the Pb2+-selective PVC membranes investigated is comparable with values obtained with optimized internal solutions of liquid-contact ISE.

[1]  P. Bühlmann,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.

[2]  E. Pretsch,et al.  Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane Electrodes , 1997 .

[3]  Ernö Pretsch,et al.  Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit. , 2002, Analytical chemistry.

[4]  E. Bakker,et al.  Effect of Transmembrane Electrolyte Diffusion on the Detection Limit of Carrier-Based Potentiometric Ion Sensors , 1998 .

[5]  J. Bobacka,et al.  Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. , 1999, Analytical chemistry.

[6]  B. Hattendorf,et al.  Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS. , 2001, Analytical chemistry.

[7]  W. E. Morf,et al.  Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes , 2002 .

[8]  R. Cattrall,et al.  Some alkylphosphoric acid esters for use in coated-wire calcium-selective electrodes: Part I. Response characteristics , 1975 .

[9]  Ernö Pretsch,et al.  Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes , 1999 .

[10]  E. Hall,et al.  Ion-transport and diffusion coefficients of non-plasticised methacrylic-acrylic ion-selective membranes. , 2004, Talanta.

[11]  A. Ivaska,et al.  Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin , 1999 .

[12]  P. Hauser,et al.  Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes. , 1998, Analytical chemistry.

[13]  E. Hall,et al.  An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range. , 2004, Analytical chemistry.

[14]  R. E. Gyurcsányi,et al.  Microfabricated ISEs: critical comparison of inherently conducting polymer and hydrogel based inner contacts. , 2004, Talanta.

[15]  A. Ivaska,et al.  All-Solid-State Chloride Sensors with Poly(3-Octylthiopene) Matrix and Trihexadecylmethylammonium Chlorides as an Ion Exchanger Salt , 2004 .

[16]  Hakhyun Nam,et al.  All-solid-state carbonate-selective electrode based on a molecular tweezer-type neutral carrier with solvent-soluble conducting polymer solid contact. , 2002, Talanta.

[17]  Ernö Pretsch,et al.  Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution , 1999 .

[18]  A. Michalska,et al.  Conducting polymer membranes for low activity potentiometric ion sensing. , 2004, Talanta.

[19]  R. E. Gyurcsányi,et al.  Tailored transport through ion-selective membranes for improved detection limits and selectivity coefficients , 1999 .

[20]  K. Maksymiuk,et al.  Studies on Spontaneous Charging/Discharging Processes of Polypyrrole in Aqueous Electrolyte Solutions , 2001 .

[21]  A. Michalska,et al.  All solid-state hydrogen ion-selective electrode based on a conducting poly(pyrrole) solid contact , 1994 .

[22]  Ernö Pretsch,et al.  Redox-Active Self-Assembled Monolayers for Solid-Contact Polymeric Membrane Ion-Selective Electrodes , 2002 .

[23]  E. Bakker Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective Electrodes , 1997 .

[24]  Johan Bobacka,et al.  Single-piece all-solid-state ion-selective electrode , 1995 .

[25]  T. Osaka,et al.  Analysis of the long-term potential stability of an all-solid-state potassium-selective electrode with electroactive polypyrrole film , 1996 .

[26]  P. Bühlmann,et al.  Selectivity of potentiometric ion sensors. , 2000, Analytical chemistry.

[27]  A. Ivaska,et al.  Influence of oxygen and carbon dioxide on the electrochemical stability of poly(3,4-ethylenedioxythiophene) used as ion-to-electron transducer in all-solid-state ion-selective electrodes , 2002 .

[28]  A. Michalska,et al.  All-Solid-State Potentiometric Sensors for Potassium and Sodium Based on Poly(pyrrole) Solid Contact , 1997 .

[29]  Richard B. Brown,et al.  Enhancing EMF stability of solid-state ion-selective sensors by incorporating lipophilic silver-ligand complexes within polymeric films , 1996 .

[30]  N. D. de Rooij,et al.  Potential Drifts of Solid‐Contacted Ion‐Selective Electrodes Due to Zero‐Current Ion Fluxes Through the Sensor Membrane , 2000 .

[31]  A. Michalska,et al.  Lowering the Detection Limit of Ion-Selective Plastic Membrane Electrodes with Conducting Polymer Solid Contact and Conducting Polymer Potentiometric Sensors , 2003 .

[32]  A. Hulanicki,et al.  Calcium-selective electrodes with pvc membranes and solid internal contacts , 1976 .

[33]  Dermot Diamond,et al.  All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact , 1992 .

[34]  P. Hauser,et al.  A potassium-ion selective electrode with valinomycin based poly(vinyl chloride) membrane and a poly(vinyl ferrocene) solid contact , 1995 .

[35]  Ernö Pretsch,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.

[36]  R. E. Gyurcsányi,et al.  Picomolar detection limits with current-polarized Pb2+ ion-selective membranes. , 2001, Analytical chemistry.

[37]  Ernö Pretsch,et al.  Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range , 2004 .