In situ imaging of paste extrusion using electrical impedance tomography

A case study is presented where electrical impedance tomography is used to image paste during extrusion. This indicates regions of high moisture at the wall of the barrel permitting slip and so making extrusion more efficient. Multi-step Gauss–Newton image reconstruction methods are used. Techniques include (i) axi-symmetric smoothing that is coupled with ultrasound measurement to provide discretization information, (ii) full impedance imaging and (iii) full three-dimensional field modelling. These provide clear images of the paste that can be used to gauge extrudability of a paste formulation.

[1]  Jari P. Kaipio,et al.  Electrical impedance tomography with basis constraints , 1997 .

[2]  J. Bridgwater,et al.  Liquid maldistribution in particulate paste extrusion , 1999 .

[3]  S. L. Rough,et al.  Effects of liquid phase migration on extrusion of microcrystalline cellulose pastes. , 2000, International journal of pharmaceutics.

[4]  Christopher J. Lawrence,et al.  Screw extrusion of food powders: prediction and performance , 2001 .

[5]  G Tomer,et al.  Measuring water distribution in extrudates using magnetic resonance imaging (MRI). , 1999, International journal of pharmaceutics.

[6]  J. Bridgwater,et al.  The extrusion mechanics of pastes—the influence of paste formulation on extrusion parameters , 1987 .

[7]  H Griffiths,et al.  An electrical impedance tomography microscope. , 1996, Physiological measurement.

[8]  Liquid Phase Migration in the Extrusion of Icing Sugar Pastes , 1998 .

[9]  J.P. Kaipio,et al.  Three-dimensional electrical impedance tomography based on the complete electrode model , 1999, IEEE Transactions on Biomedical Engineering.

[10]  Denyer Cwl Electronics for real-time and three-dimensional electrical impedance tomographs. , 1996 .

[11]  John Bridgwater,et al.  Liquid migration in paste extrusion : Advanced materials , 1995 .

[12]  Mark A. Bennett,et al.  Application-specific optimization of regularization for electrical impedance tomography , 2001 .

[13]  R. M. Nedderman,et al.  Die entry pressure drops in paste extrusion , 1998 .

[14]  E. Somersalo,et al.  Inverse problems with structural prior information , 1999 .

[15]  L M Heikkinen,et al.  A MATLAB package for the EIDORS project to reconstruct two-dimensional EIT images , 2001, Physiological measurement.

[16]  Xiaodong Jia,et al.  QUANTIFICATION OF SOLID-LIQUID MIXING USING ELECTRICAL RESISTANCE AND POSITRON EMISSION TOMOGRAPHY , 1999 .