Standardization of needlestick injury and evaluation of a novel virus-inhibiting protective glove.

Rubber surgical gloves worn as a barrier to prevent contamination from body fluids offer relative protection against contamination through direct percutaneous injuries involving needles, scalpel blades or bone fragments. To determine the main experimental parameters influencing the volume of blood transmitted by a hollow-bore needle (worst case scenario) during an accidental puncture, we designed an automatic puncture apparatus. Herpes simplex type 1 virus (HSV1), a model for enveloped viruses, was used as a 'marker' in an in-vitro gelatine model. Of the experimental parameters studied, the most critical influences were found to be needle diameter and puncture depth, whereas puncture speed, puncture angle and glove-stretching feature appeared to be less influential. A single glove reduced the volume of blood transferred by 52% compared with no glove, but double gloving offered no additional protection against hollow-bore needle punctures. Using 'standardized' puncture conditions, the virus-inhibiting surgical glove G-VIR elicited an 81% reduction in the amount of HSV1 transmitted as compared with single or double latex glove systems.

[1]  A. Bigi,et al.  Relationship between triple-helix content and mechanical properties of gelatin films. , 2004, Biomaterials.

[2]  M. Ardo,et al.  A Case–Control Study of HIV Seroconversion in Health Care Workers after Percutaneous Exposure , 2009 .

[3]  J. Gerberding,et al.  Efficacy of gloves in reducing blood volumes transferred during simulated needlestick injury. , 1993, The Journal of infectious diseases.

[4]  W. Russell A Sensitive and Precise Plaque Assay for Herpes Virus , 1962, Nature.

[5]  D. Katzenstein,et al.  Detection and Qualification of Human Immunodeficiency Virus RNA in Patient Serum by Use of the Polymerase Chain Reaction , 1991 .

[6]  J. Tanner,et al.  Double gloving to reduce surgical cross-infection. , 2002, The Cochrane database of systematic reviews.

[7]  J. Crance,et al.  Rapid inactivation of vaccinia virus in suspension and dried on surfaces. , 2004, The Journal of hospital infection.

[8]  W. Blackwelder,et al.  Virus‐inhibiting surgical glove to reduce the risk of infection by enveloped viruses , 2003, Journal of medical virology.

[9]  J. Gerberding Occupational Exposure to HIV in Health Care Settings , 2003 .

[10]  J. Mcgowan,et al.  How much blood is in a needlestick? , 1987, The Journal of infectious diseases.

[11]  V. Puro,et al.  Occupational transmission of hepatitis C virus. , 2002, JAMA.

[12]  Günter Reiter,et al.  Biocide squirting from an elastomeric tri-layer film , 2004, Nature materials.

[13]  D. Cardo,et al.  A case-control study of HIV seroconversion in health care workers after percutaneous exposure. Centers for Disease Control and Prevention Needlestick Surveillance Group. , 1997, The New England journal of medicine.

[14]  Quantitation of human immunodeficiency virus type 1 in the blood of infected persons. , 1990, Disease markers.

[15]  D. Katzenstein,et al.  Detection and quantification of human immunodeficiency virus RNA in patient serum by use of the polymerase chain reaction. , 1991, The Journal of infectious diseases.