Comparison between cuff-based and radial tonometry exercise-induced central blood pressure

PurposeNon-invasive central blood pressure assessed during exercise may provide better cardiovascular prognostic than measurements taken at rest. Radial tonometry is the only technique validated to perform this type of assessment; however, it relies on the experience of the tester. Cuff-based devices have been developed to avoid operator dependency, although these systems have yet to be validated during exercise. The purpose of this study was to compare exercise-induced central blood pressure estimations between a cuff-based device and radial tonometry.MethodsTwenty young healthy subjects were recruited to perform a three-workload steady-state exercise test at blood lactate levels of < 2, 2–4, and > 4 mmol/L, respectively. Central systolic and diastolic blood pressure (cSBP and cDBP, respectively), central pulse pressure (cPP), and augmentation index (AIx) were assessed at rest and during each workload with a cuff-based device and radial tonometry. Statistical analysis included Bland–Altman analysis for agreement between techniques. Agreement was considered when 95% of the data set for each central blood pressure parameter was within 1.96 standard deviations from the mean difference. Significance was considered at α = 0.05.ResultsCentral blood pressure measurements with the cuff device were obtained only at rest and during low-intensity exercise. During low-intensity exercise, all measurements showed agreement between both devices (cSBP 95% CI [− 6.0 to 10.7], cDBP 95% CI [− 4.5 to 6.3], cPP 95% CI [− 4.7 to 8.3], and AIx (95% CI [− 20.1 to 22.2]).ConclusionA cuff-based device can estimate central blood pressure at low-intensity exercise, without operator dependency, and showing agreement to radial tonometry.

[1]  K. Furie,et al.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2007, Circulation.

[2]  J. Sharman,et al.  Pulse wave analysis is a reproducible technique for measuring central blood pressure during hemodynamic perturbations induced by exercise. , 2008, American journal of hypertension.

[3]  W. Abhayaratna,et al.  Comparison of Central Blood Pressure Estimated by a Cuff-Based Device With Radial Tonometry. , 2016, American journal of hypertension.

[4]  K. Furie,et al.  Heart disease and stroke statistics--2007 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2008, Circulation.

[5]  J. Sharman,et al.  Patients with type 2 diabetes have exaggerated brachial and central exercise blood pressure: relation to left ventricular relative wall thickness. , 2008, American journal of hypertension.

[6]  B. Wallin,et al.  Sympathetic nervous system and blood pressure in humans: individualized patterns of regulation and their implications. , 2010, Hypertension.

[7]  Daniel E Forman,et al.  Exercise standards for testing and training: a scientific statement from the American Heart Association. , 2013, Circulation.

[8]  A. Hughes,et al.  Arterial pressure: agreement between a brachial cuff-based device and radial tonometry , 2014, Journal of hypertension.

[9]  A. Gurovich,et al.  Clinical Markers of Exercise Intensity as a Surrogate for Blood Lactate Levels Only During Low-Intensity Exercise in Patients With Coronary Artery Disease , 2018, Cardiopulmonary Physical Therapy Journal.

[10]  Thomas H Marwick,et al.  Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise , 2006, Hypertension.

[11]  S. Millasseau,et al.  Non-invasive estimation of aortic blood pressures: a close look at current devices and methods. , 2014, Current pharmaceutical design.

[12]  Darren P. Casey,et al.  Central, peripheral and resistance arterial reactivity: fluctuates during the phases of the menstrual cycle , 2010, Experimental biology and medicine.

[13]  J. Evans Straightforward Statistics for the Behavioral Sciences , 1995 .

[14]  D. Altman,et al.  Comparing methods of measurement: why plotting difference against standard method is misleading , 1995, The Lancet.

[15]  Yoshio Kobayashi,et al.  Invasive validation of a novel brachial cuff-based oscillometric device (SphygmoCor XCEL) for measuring central blood pressure , 2017, Journal of hypertension.

[16]  B. Williams,et al.  Effects of exercise on central aortic pressure before and after treatment with renin–angiotensin system blockade in patients with hypertension , 2015, Journal of the renin-angiotensin-aldosterone system : JRAAS.

[17]  J. Sharman,et al.  Pulse pressure amplification during exercise is significantly reduced with age and hypercholesterolemia , 2007, Journal of hypertension.

[18]  P. Thompson,et al.  ACSM's Guidelines for Exercise Testing and Prescription , 1995 .

[19]  Yutaka Imai,et al.  European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults , 2010, Blood pressure monitoring.

[20]  A. Gurovich,et al.  Pulse wave analysis and pulse wave velocity techniques: are they ready for the clinic? , 2011, Hypertension Research.

[21]  R. Arena,et al.  Reference Standards for Cardiorespiratory Fitness Measured With Cardiopulmonary Exercise Testing Using Cycle Ergometry: Data From the Fitness Registry and the Importance of Exercise National Database (FRIEND) Registry , 2017, Mayo Clinic proceedings.

[22]  Mark D. Huffman,et al.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association. , 2013, Circulation.

[23]  E. Lakatta,et al.  Hypertension Derivation and Validation of Diagnostic Thresholds for Central Blood Pressure Measurements Based on Long-Term Cardiovascular Risks , 2022 .

[24]  K. Stone,et al.  Reliability of oscillometric central blood pressure responses to lower limb resistance exercise. , 2018, Atherosclerosis.

[25]  R. Diaz,et al.  Comparison of the Observed Heart Rate during Blood Lactate‐based Exercise Intensity vs. Three Heart Rate‐based Methods in Cardiovascular Rehabilitation , 2014 .

[26]  O. Faude,et al.  Lactate Threshold Concepts , 2009, Sports medicine.

[27]  A. Hughes,et al.  Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization , 2017, European heart journal.

[28]  Lawrence A Leiter,et al.  Hypertension Canada's 2017 Guidelines for Diagnosis, Risk Assessment, Prevention, and Treatment of Hypertension in Adults. , 2017, The Canadian journal of cardiology.

[29]  Richard B. Devereux,et al.  Central Pressure More Strongly Relates to Vascular Disease and Outcome Than Does Brachial Pressure: The Strong Heart Study , 2007, Hypertension.

[30]  J. Faulkner,et al.  Reliability of oscillometric central blood pressure responses to submaximal exercise , 2016, Journal of hypertension.

[31]  Mark Butlin,et al.  Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[32]  B. Barrett,et al.  Screening strategies for cardiovascular disease in asymptomatic adults. , 2014, Primary care.

[33]  J. Cockcroft,et al.  Central blood pressure: current evidence and clinical importance. , 2014, European heart journal.

[34]  A. Dart,et al.  Accuracy of automated auscultatory blood pressure measurement during supine exercise and treadmill stress electrocardiogram-testing , 2004, Blood pressure monitoring.

[35]  Yoshio Kobayashi,et al.  Validity of the augmentation index and pulse pressure amplification as determined by the SphygmoCor XCEL device: a comparison with invasive measurements , 2018, Hypertension Research.

[36]  Liu Yuxiu,et al.  Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. , 2016 .

[37]  Jeffrey S. Martin,et al.  The acute effects of smokeless tobacco on central aortic blood pressure and wave reflection characteristics , 2010, Experimental biology and medicine.

[38]  Darren P. Casey,et al.  Association of age with timing and amplitude of reflected pressure waves during exercise in men. , 2011, American journal of hypertension.

[39]  W. Nichols,et al.  Validity and reliability of aortic pulse wave velocity and augmentation index determined by the new cuff-based SphygmoCor Xcel , 2014, Journal of Human Hypertension.