Imaging Electric Properties of Biological Tissues by RF Field Mapping in MRI

The electric properties (EPs) of biological tissue, i.e., the electric conductivity and permittivity, can provide important information in the diagnosis of various diseases. The EPs also play an important role in specific absorption rate calculation, a major concern in high-field MRI, as well as in nonmedical areas such as wireless telecommunications. The high-field MRI system is accompanied by significant wave propagation effects, and the RF radiation is dependent on the EPs of biological tissue. On the basis of the measurement of the active transverse magnetic component of the applied RF field (known as B1-mapping technique), we propose a dual-excitation algorithm, which uses two sets of measured B1 data to noninvasively reconstruct the EPs of biological tissues. The finite-element method was utilized in 3-D modeling and B1 field calculation. A series of computer simulations were conducted to evaluate the feasibility and performance of the proposed method on a 3-D head model within a TEM coil and a birdcage coil. Using a TEM coil, when noise free, the reconstructed EP distribution of tissues in the brain has relative errors of 12%-28% and correlated coefficients of greater than 0.91. Compared with other B1-mapping-based reconstruction algorithms, our approach provides superior performance without the need for iterative computations. The present simulation results suggest that good reconstruction of EPs from B1 mapping can be achieved.

[1]  Kay Nehrke,et al.  In vivo determination of electric conductivity and permittivity using a standard MR system , 2007 .

[2]  E M Haacke,et al.  Extraction of conductivity and permittivity using magnetic resonance imaging , 1991 .

[3]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[4]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[5]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[6]  X. Li,et al.  Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensions , 2002, IEEE Transactions on Biomedical Engineering.

[7]  F. Franconi,et al.  Radiofrequency map of an NMR coil by imaging. , 1993, Magnetic resonance imaging.

[8]  S. S. Chaudhary,et al.  Dielectric properties of normal & malignant human breast tissues at radiowave & microwave frequencies. , 1984, Indian journal of biochemistry & biophysics.

[9]  A. Malicha,et al.  Additional value of electrical impedance scanning : experience of 240 histologically-proven breast lesions , 2001 .

[10]  W. Joines,et al.  The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. , 1994, Medical physics.

[11]  Y Ziya Ider,et al.  Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density. , 2004, Physiological measurement.

[12]  Keith D. Paulsen,et al.  Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects , 2002, IEEE Transactions on Medical Imaging.

[13]  Peter P. Silvester,et al.  Finite elements for electrical engineers: Curvilinear, vectorial and unbounded elements , 1996 .

[14]  M Alecci,et al.  Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties , 2001, Magnetic resonance in medicine.

[15]  Xu Li,et al.  Reconstruction of Vectorial Acoustic Sources in Time-Domain Tomography , 2009, IEEE Transactions on Medical Imaging.

[16]  D. Hoult The principle of reciprocity in signal strength calculations—a mathematical guide , 2000 .

[17]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[18]  D. C. Barber,et al.  Three-dimensional electrical impedance tomography , 1996, Nature.

[19]  G. Metzger,et al.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurements , 2008, Magnetic resonance in medicine.

[20]  L. Bolinger,et al.  Mapping of the Radiofrequency Field , 1993 .

[21]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[22]  G. Bruce Pike,et al.  Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI , 1998, IEEE Transactions on Medical Imaging.

[23]  R. Constable,et al.  Measurement and correction of transmitter and receiver induced nonuniformities in vivo , 2005, Magnetic resonance in medicine.

[24]  J. Kong Electromagnetic Wave Theory , 1986 .

[25]  K. Uğurbil,et al.  Efficient high‐frequency body coil for high‐field MRI , 2004, Magnetic resonance in medicine.

[26]  K. Uğurbil,et al.  Analysis of wave behavior in lossy dielectric samples at high field , 2002, Magnetic resonance in medicine.

[27]  Petra Schmalbrock,et al.  In‐depth study of the electromagnetics of ultrahigh‐field MRI , 2007, NMR in biomedicine.

[28]  Jianming Jin Electromagnetic Analysis and Design in Magnetic Resonance Imaging , 1998 .

[29]  Bin He,et al.  Noninvasive Imaging of Head-Brain Conductivity Profiles , 2008, IEEE Engineering in Medicine and Biology Magazine.

[30]  Byung Il Lee,et al.  J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images , 2002, IEEE Transactions on Medical Imaging.

[31]  S. Vijayakumar,et al.  SAR simulation and the effect of mode coupling in a birdcage resonator , 2007 .

[32]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[33]  H Griffiths,et al.  Magnetic Induction Tomography: A Measuring System for Biological Tissues , 1999, Annals of the New York Academy of Sciences.

[34]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[35]  M. Joy,et al.  In vivo detection of applied electric currents by magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[36]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[37]  Han Wen,et al.  Noninvasive quantitative mapping of conductivity and dielectric distributions using RF wave propagation effects in high-field MRI , 2003, SPIE Medical Imaging.

[38]  Tobias Voigt,et al.  Electrical conductivity imaging using magnetic resonance tomography , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[39]  Jean-Pierre Berenger,et al.  A perfectly matched layer for the absorption of electromagnetic waves , 1994 .

[40]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.