Improvement of Left Ventricular Ejection Time Measurement in the Impedance Cardiography Combined with the Reflection Photoplethysmography
暂无分享,去创建一个
Shing-Hong Liu | Da-Chuan Cheng | Chun-Hung Su | Jia-Jung Wang | Shing-Hong Liu | D. Cheng | Jia-Jung Wang | C. Su
[1] Ulrich Limper,et al. Upright cardiac output measurements in the transition to weightlessness during parabolic flights. , 2011, Aviation, space, and environmental medicine.
[2] Thomas Anthony Anderson,et al. Continuous noninvasive cardiac output in children: is this the next generation of operating room monitors? Initial experience in 402 pediatric patients , 2015, Paediatric anaesthesia.
[3] Paweł Krzesiński,et al. The effects of cardiac rehabilitation on haemodynamic parameters measured by impedance cardiography in patients with heart failure. , 2011, Kardiologia polska.
[4] Jean Lonsdorfer,et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method , 2000, European Journal of Applied Physiology.
[5] Atul Malhotra,et al. Effect of mild, asymptomatic obstructive sleep apnea on daytime heart rate variability and impedance cardiography measurements. , 2012, The American journal of cardiology.
[6] W. J. Tompkins,et al. Motion Artifact from Spot and Band Electrodes During Impedance Cardiography , 1986, IEEE Transactions on Biomedical Engineering.
[7] L. Stegagno,et al. Sleep onset and cardiovascular activity in primary insomnia , 2011, Journal of sleep research.
[8] Gerard Cybulski,et al. Impedance cardiography: recent advancements. , 2012, Cardiology journal.
[9] Richard D Branson,et al. Forehead oximetry in critically ill patients: the case for a new monitoring site. , 2004, Respiratory care clinics of North America.
[10] Robert M. Kacmarek,et al. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery , 2015, Journal of Clinical Monitoring and Computing.
[11] Sandeep Chauhan,et al. Comparison of the Hemodynamic Effects of the Induction Agents Ketamine, Etomidate and Sevoflurane Using the Model of Electrical Velocimetry Based Cardiac Output Monitoring in Pediatric Cardiac Surgical Patients , 2014 .
[12] D B Newlin,et al. Pre-ejection period: measuring beta-adrenergic influences upon the heart. , 1979, Psychophysiology.
[13] S. Ahmed,et al. Systolic Time Intervals as Measures of the Contractile State of the Left Ventricular Myocardium in Man , 1972, Circulation.
[14] D. Dutka,et al. Cardiac Resynchronization Therapy Optimization Using Noninvasive Cardiac Output Measurement , 2011, Pacing and clinical electrophysiology : PACE.
[15] William C. Shoemaker,et al. Meta-analysis of hemodynamic optimization in high-risk patients* , 2002, Critical care medicine.
[16] J. J. Carr,et al. Introduction to Biomedical Equipment Technology , 1981 .
[17] Arthur P DeMarzo,et al. Using impedance cardiography with postural change to stratify patients with hypertension , 2011, Therapeutic advances in cardiovascular disease.
[18] D P Bernstein,et al. A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale , 1986, Critical care medicine.
[19] J. Teboul,et al. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. , 2002, Chest.