Reliability of telemedicine examination.

OBJECTIVES To assess the reliability of telemedicine examination and identify the issues to be addressed if the conduct of physical examination and the reading of images and tracings by telemedicine are to be as reliable as conventional examination and reading. METHODS Patients were examined both conventionally and by telemedicine in 12 clinics, and the results were compared. There were 1826 matched pairs of observations. Cardiac auscultation, echocardiography, electrocardiography, electroencephalography, obstetric ultrasonography, ophthalmologic examination, physical therapy assessment, pulmonary auscultation, and the reading of chest radiographs with telemedicine cameras and monitors were studied. The main outcome measure was agreement between the telemedicine findings and a criterion standard. RESULTS For ophthalmology, physical therapy, and cardiac auscultation, 91.2% of the conventional findings and 86.5% of the telemedicine findings were identical or similar to the criterion standard. The kappa coefficient on matched-pair analysis was 0.66. For pulmonary auscultation and reading of chest films with a telemedicine camera and monitor abnormalities were suppressed at default settings but subsequently revealed with extensive manipulation of system settings. For tracings and images, both conventional and telemedicine findings showed 92% reliability, with a kappa coefficient of 0.87. CONCLUSIONS On the basis of these observations and the methods used, reliability varied with the type of examination, clinician experience with telemedicine, and participant knowledge of system limitations. Clinicians without experience or knowledge of system limitations missed findings of clinical importance. Improvements in equipment since the clinics were conducted in 1994 may have resolved some of these problems. Our findings raise doubts about the reliability of occasional telemedicine consultations by clinicians inexperienced in the technology.

[1]  L. Snyder-Mackler,et al.  Interrater reliability of videotaped observational gait-analysis assessments. , 1991, Physical therapy.

[2]  R. Miller,et al.  The Detection of Heart Disease in Children: Results of a Mass Field Trial with Use of Tape‐Recorded Heart Sounds , 1962, Circulation.

[3]  E V Dunn,et al.  Provider acceptance of telemedicine systems in remote areas of Ontario. , 1984, The Journal of family practice.

[4]  W. J. Tuddenham Visual search, image organization, and reader error in roentgen diagnosis. Studies of the psycho-physiology of roentgen image perception. , 1962, Radiology.

[5]  D. Groom Auscultation of faint heart murmurs. , 1957, Postgraduate medicine.

[6]  D. Riddle,et al.  Reliability and validity of judgments of the integrity of the anterior cruciate ligament of the knee using the Lachman's test. , 1990, Physical therapy.

[7]  R. Bashshur,et al.  Assessment of telemedicine: results of the initial experience. , 1977, Aviation, space, and environmental medicine.

[8]  C. van Weel,et al.  Diagnosing diabetic retinopathy by general practitioners and by a hospital physician. The use of fundus photos. , 1990, Scandinavian journal of primary health care.

[9]  Maxine L. Rockoff,et al.  Book reviewTelemedicine: Explorations in the use of telecommunications in health care: edited by Rashid L. Bashshur, Patricia A. Armstrong and Zakhour I. Youssef. Charles C. Thomas, Springfield, Il., 1975. 356 pp. $21.75 (paper) $18.75. , 1977 .

[10]  R. Rushmer,et al.  Variability in detection and interpretation of heart murmurs; a comparison of auscultation and stethography. , 1952, A.M.A. American journal of diseases of children.

[11]  K. Fellows,et al.  Noninvasive tests in the initial evaluation of heart murmurs in children. , 1983, The New England journal of medicine.

[12]  J P Miller,et al.  Intrarater reliability of manual muscle test (Medical Research Council scale) grades in Duchenne's muscular dystrophy. , 1992, Physical therapy.

[13]  R Varma,et al.  Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma. , 1994, Ophthalmology.

[14]  L. Koran,et al.  The reliability of clinical methods, data and judgments (second of two parts). , 1975, The New England journal of medicine.

[15]  P. Vlad,et al.  Initial evaluation of heart murmurs: Are laboratory tests necessary? , 1990, Pediatrics.

[16]  Herbert J. Oyer,et al.  Aging and Communication. , 1976 .

[17]  T. Hutchinson,et al.  Interobserver agreement by auscultation in the presence of a third heart sound in patients with congestive heart failure. , 1987, Chest.

[18]  R. Murphy,et al.  Accuracy of cardiac auscultation by microwave. , 1973, Chest.

[19]  D. Riddle,et al.  Intertester reliability of clinical judgments of medial knee ligament integrity. , 1989, Physical therapy.

[20]  S Miglior,et al.  Suitability of slit lamp retroillumination photographs for classifying cataracts according to 'Lens Opacities Classification System II (LOCS II)'. , 1992, Current eye research.

[21]  L. Fajardo,et al.  Diagnostic Performance of Teleradiology in Cervical Spine Fracture Detection , 1992, Investigative radiology.

[22]  M. González,et al.  Concordance in diagnosis of diabetic retinopathy by fundus photography between retina specialists and a standardized reading center. Mexico City Diabetes Study Retinopathy Group. , 1995, Archives of medical research.

[23]  P. Stratford,et al.  Interrater reliability of lumbar accessory motion mobility testing. , 1995, Physical therapy.

[24]  S Abraham,et al.  Telephone transmission of cardiac and pulmonary data. , 1969, Archives of environmental health.

[25]  César Cáceres,et al.  The innocent murmur : a problem in clinical practice , 1967 .

[26]  R. Shields,et al.  Reliability, validity, and responsiveness of functional tests in patients with total joint replacement. , 1995, Physical therapy.

[27]  R. Miller,et al.  Use of Tape‐Recorded Heart Sounds in Screening of Children for Heart Disease , 1959, Circulation.

[28]  D. Riddle,et al.  Intertester reliability of judgments of the presence of trigger points in patients with low back pain. , 1992, Archives of physical medicine and rehabilitation.

[29]  F J Staub OR consultation by telemedicine. , 1977, AORN journal.

[30]  K. Roach,et al.  Reliability and validity of the Acute Care Index of Function for patients with neurologic impairment. , 1988, Physical therapy.

[31]  C. Goldsmith,et al.  Training users in the gross motor function measure: methodological and practical issues. , 1994, Physical therapy.

[32]  E. Raftery,et al.  Examination of the heart: an investigation into variation. , 1967, American journal of epidemiology.

[33]  L T Chylack,et al.  Lens opacities classification system II (LOCS II) , 1989, Archives of ophthalmology.

[34]  E V Dunn,et al.  A clinical evaluation of four alternative telemedicine systems. , 1977, Behavioral science.