Performance analysis of an ejector enhanced refrigeration cycle with R290/R600a for application in domestic refrigerator/freezers

Abstract This study presents an ejector enhanced vapor compression refrigeration cycle (EVRC) using zeotropic mixture R290/R600a for domestic refrigerator/freezers. An ejector and a phase separator are adopted in EVRC to enhance the cycle performance. Energetic and exergetic analysis methods are utilized to theoretically investigate the system operating performance of EVRC and compared with the traditional vapor compression refrigeration cycle (TVRC). The results demonstrate that EVRC outperforms TVRC and exhibits higher coefficient of performance (COP), volumetric cooling capacity and exergy efficiency. Under the given operation condition, the system performance improvement of EVRC over TVRC in the aspect of COP, volumetric cooling capacity and exergy efficiency can reach up to 14.2%, 37% and 17.7%, respectively. The performance characteristics of the proposed novel cycle show its potential advantages for application in domestic refrigerator/freezers.

[1]  Eckhard A. Groll,et al.  Investigation on performance of variable geometry ejectors for CO2 refrigeration cycles , 2012 .

[2]  H. Kursad Ersoy,et al.  Performance improvement of the vapour compression refrigeration cycle by a two‐phase constant area ejector , 2009 .

[3]  S. Jayaraj,et al.  Environment friendly alternatives to halogenated refrigerants—A review , 2009 .

[4]  Neal Lawrence,et al.  Theoretical and practical comparison of two-phase ejector refrigeration cycles including First and Second Law analysis , 2013 .

[5]  Xianbiao Bu,et al.  Performance characteristics of R1234yf ejector-expansion refrigeration cycle , 2014 .

[6]  M. Elakdhar,et al.  Analysis of a Compression/Ejection Cycle for Domestic Refrigeration , 2007 .

[7]  Hyun Joon Chung,et al.  Performance optimization of a Lorenz–Meutzner cycle charged with hydrocarbon mixtures for a domestic refrigerator-freezer , 2012 .

[8]  S. Wongwises,et al.  Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator , 2005 .

[9]  Juan M. Belman-Flores,et al.  Enhancements in domestic refrigeration, approaching a sustainable refrigerator – A review , 2015 .

[10]  Mehdi Rasti,et al.  Enhancement of domestic refrigerator’s energy efficiency index using a hydrocarbon mixture refrigerant , 2012 .

[11]  Li Zhao,et al.  Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system , 2004 .

[12]  Khalid A. Joudi,et al.  Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants , 2003 .

[13]  M. Fatouh,et al.  Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigerators , 2006 .

[14]  B. Palm Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review , 2008 .

[15]  Jianlin Yu,et al.  Theoretical investigation on an ejector–expansion refrigeration cycle using zeotropic mixture R290/R600a for applications in domestic refrigerator/freezers , 2015 .

[16]  Haoran Chen,et al.  Experimental study on a multi-evaporator refrigeration system with variable area ratio ejector , 2016 .

[17]  S. Jayaraj,et al.  Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator , 2009 .

[18]  A. S. Dalkılıç,et al.  A performance comparison of vapour-compression refrigeration system using various alternative refrigerants , 2010 .

[19]  Ma Yitai,et al.  Thermodynamic analysis of transcritical CO2 refrigeration cycle with an ejector , 2011 .

[20]  Jianlin Yu,et al.  Performance analysis of a new ejector enhanced vapor injection heat pump cycle , 2015 .

[21]  Fangming Jiang,et al.  A novel transcritical CO2 refrigeration cycle with two ejectors , 2012 .

[22]  Jianlin Yu,et al.  Energy and exergy analysis of zeotropic mixture R290/R600a vapor-compression refrigeration cycle with separation condensation , 2015 .

[23]  Cui Li,et al.  Experimental study on performance of a hybrid ejector-vapor compression cycle , 2016 .

[24]  Jianyong Chen,et al.  A review on versatile ejector applications in refrigeration systems , 2015 .

[25]  Jahar Sarkar,et al.  Ejector enhanced vapor compression refrigeration and heat pump systems—A review , 2012 .

[26]  Arif Hepbasli,et al.  Energetic and exergetic comparison of basic and ejector expander refrigeration systems operating under the same external conditions and cooling capacities , 2015 .

[27]  S. Klein,et al.  NIST Standard Reference Database 23: NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP, Version 6.0 | NIST , 1998 .

[28]  D. Jung,et al.  Testing of propane/isobutane mixture in domestic refrigerators , 2000 .

[29]  Jahar Sarkar,et al.  Performance analyses of novel two-phase ejector enhanced multi-evaporator refrigeration systems , 2017 .

[30]  Eckhard A. Groll,et al.  Transcritical CO2 refrigeration cycle with ejector-expansion device , 2005 .

[31]  P. Somasundaram,et al.  Exergy and energy analysis of three stage auto refrigerating cascade system using Zeotropic mixture for sustainable development , 2014 .

[32]  Dong Yeon Lee,et al.  Performance characteristics of a small-capacity directly cooled refrigerator using R290/R600a (55/45) , 2008 .

[33]  E. Granryd Hydrocarbons as refrigerants — an overview , 2001 .

[34]  Farid Nasir Ani,et al.  A review on two-phase ejector as an expansion device in vapor compression refrigeration cycle , 2012 .

[35]  Li Zhao,et al.  Experimental research on the influence of system parameters on the composition shift for zeotropic mixture (isobutane/pentane) in a system occurring phase change , 2016 .

[36]  V. Selladurai,et al.  Experimental analysis of a new refrigerant mixture as drop-in replacement for CFC12 and HFC134a , 2008 .

[37]  Ruzhu Wang,et al.  Progress of mathematical modeling on ejectors , 2009 .

[38]  Omar Abdelaziz,et al.  Advances in household appliances- A review , 2011 .

[39]  Jia Yan,et al.  Numerical investigation of geometry parameters for pressure recovery of an adjustable ejector in multi-evaporator refrigeration system , 2013 .

[40]  Mingyan Zhang,et al.  Compression-injection hybrid refrigeration cycles in household refrigerators , 2010 .

[41]  Yiping Dai,et al.  Exergy analysis, parametric analysis and optimization for a novel combined power and ejector refrigeration cycle , 2009 .

[42]  James M. Calm,et al.  The next generation of refrigerants – Historical review, considerations, and outlook , 2008 .

[43]  Bukola Olalekan Bolaji,et al.  Ozone depletion and global warming: Case for the use of natural refrigerant – a review , 2013 .