Gated fiber-optic-coupled detector for in vivo real-time radiation dosimetry.

Gated detection of the output of a fiber-optic-coupled radiation dosimeter effectively eliminated the direct contribution of Cerenkov radiation to the signal. The radiation source was an external beam radiotherapy machine that provided pulses of 6-MeV x rays. Gated detection was used to discriminate the signal collected during the radiation pulses, including Cerenkov interference, from the signal collected between the radiation pulses due only to phosphorescence from the Cu(1+)-doped glass detector. Gated detection of the long-lived phosphorescence of the Cu(1+)-doped glass provided real-time dose measurements that were linear with the absorbed dose and that were accurate for all field sizes studied.

[1]  M. Villegas,et al.  Luminescence time decay from Cu+ ions in sol–gel silica coatings , 2001 .

[2]  A S Beddar,et al.  Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry , 1993 .

[3]  R. Altemus,et al.  Optically stimulated luminescent glass optical fibre dosemeter. , 2002, Radiation protection dosimetry.

[4]  B. Moine,et al.  Optical spectroscopy of monovalent copper-doped borate glasses , 1990 .

[5]  Kevin J. Jordan,et al.  Evaluation of ruby as a fluorescent sensor for optical fiber-based radiation dosimetry , 1996, Photonics West.

[6]  C. Sibata,et al.  A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery , 2001 .

[7]  Alan L. Huston,et al.  Remote optical fiber dosimetry , 2001 .

[8]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[9]  R. Schmidt-Ullrich,et al.  Radiation-induced light in optical fibers and plastic scintillators: application to brachytherapy dosimetry , 1996 .

[10]  A. Beddar A new scintillator detector system for the quality assurance of 60Co and high-energy therapy machines. , 1994, Physics in medicine and biology.

[11]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[12]  A. Huston,et al.  Optically stimulated luminescence dosimetry using doped fused quartz , 1999 .

[13]  Yves Charon,et al.  SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and practical characteristics , 2000 .

[14]  Thomas R. Mackie,et al.  Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams , 1992 .

[15]  Natalka Suchowerska,et al.  Plastic scintillation dosimetry: optimization of light collection efficiency. , 2003, Physics in medicine and biology.