Experimental Study on Ion-Flow Fields Inside Greenhouse Models Underneath the DC Test Wire

With more HVDC transmission lines being built in China, the situation of the plastic greenhouses existing underneath the HVDC lines is becoming more common when the transmission lines pass over the farmland. The ionic space charges generated by corona discharge of HVDC transmission lines strengthen the electric field at the ground level. And with the accumulation of the ionic space charges on the surface of the plastic greenhouses, the ion-flow fields are highly perturbed. In this paper, a set of single conductor experiments is performed in the laboratory. Extensive measurements are carried out for different voltages and polarities with different types of plastic greenhouse models. The main goal of this work is to make it clear that whether or not the presence of greenhouses would affect the ion-flow fields and ion current density inside the greenhouse models. And through the analysis and discussion, we find out the differences of the ion-flow fields when the greenhouse models exist or not, which is the foundation of the future research.

[1]  Li Xiaolin,et al.  Development of ± 800kV UHVDC Transmission Technology in China , 2008, 2008 International Conference on High Voltage Engineering and Application.

[2]  M. Abdel-Salam,et al.  Finite element solution of monopolar corona on bundle conductors , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[3]  Xiaoyu Yang,et al.  An overview of power transmission systems in China , 2010 .

[4]  Tadasu Takuma,et al.  A Very Stable Calculation Method for Ion Flow Field of HVDC Transmission Line , 1987, IEEE Power Engineering Review.

[5]  Wang Xinxin,et al.  Dielectric Barrier Discharge and Its Applications , 2009 .

[6]  P. Maruvada Corona-Generated Space Charge Environment in the Vicinity of HVDC Transmission Lines , 1982, IEEE Transactions on Electrical Insulation.

[7]  Zhang Jie Calculation of Shielding Effectiveness of Metal Wire Mesh of Cable , 2010 .

[8]  Xiang Cui,et al.  Spatial Distribution of Ion Current Around HVDC Bundle Conductors , 2012, IEEE Transactions on Power Delivery.

[9]  Xiang Cui,et al.  The Ionized Fields and the Ion Current on a Human Model Under $\pm$ 800-kV HVDC Transmission Lines , 2012, IEEE Transactions on Power Delivery.

[10]  Tsutomu Ikeda,et al.  Calculation of ION Flow Fields of HVDC Transmission Lines By the Finite Element Method , 1981, IEEE Transactions on Power Apparatus and Systems.

[11]  L. Sevgi Electromagnetic Screening and Shielding-Effectiveness (SE) Modeling , 2009, IEEE Antennas and Propagation Magazine.

[12]  X. Cui,et al.  Calculation of the 3-D Ionized Field Under HVDC Transmission Lines , 2011, IEEE Transactions on Magnetics.

[13]  Koo Yong Shin,et al.  Test on the Environmental Characteristics of HVDC Overhead Transmission Line Using Reduced-scale Model , 2011 .

[14]  K. Yasuoka,et al.  Surface charge measurement in surface dielectric barrier discharge by laser polarimetry , 2011 .

[15]  Wasyl Janischewskyj,et al.  Analysis of Corona Losses on DC Transmission Lines: I - Unipolar Lines , 1969 .